DeWalt DWFP12569 instruction manual Lubrication

Page 5

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL_MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.

FITTINGS:

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected from the supply source.

HOSES:

Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm2) working pressure rating or 150 percent of the maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” from the male plug on the tool.

SUPPLY SOURCE:

Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE

GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE.

REGULATOR:

A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 KG/CM2) is required to control the operat ingi pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 KG/CM2) as tool may fracture or burst, possibly causing injury.

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased.The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance.

LUBRICATION

Frequent, but not excessive, lubrication is required for best performance. Use Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance. Only a few drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle.

COLD WEATHER OPERATION:

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of winter formula air tool lubricant or permanent antifreeze (ethylene glycol) as a cold weather lubricant.

CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure.

NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low temperature air dryers without checking compatibility.

-5-

Image 5
Contents DWFP12569 Introduction Index Three Years Limited WarrantyAIR Supply and Connections Safety InstructionsLoading Tool OperationTool AIR Fitting Fastener SpecificationsOperating Pressure AIR ConsumptionLubrication Before Handling or Operating this Tool Loading the DWFP12569To Prevent Accidental Injuries Cleat LoadingAssembly Procedure for Seals Replacement PartsAIR SUPPLY-PRESSURE and Volume Maintaining the Pneumatic ToolTo Replace Piston Maintaining the DWFP12569 Series ToolsProblem Cause Correction Trouble ShootingAccessories Available Garantía Limitada POR Tres Años Introducción ÍndiceNota Suministro DE Aire Y Conexiones Instrucciones DE SeguridadCarga DE LA Herramienta FuncionamientoEspecificaciones DEL Sujetador Especificaciones DE LA Herramienta DWFP12569Conexión DE Aire DE LA Herramienta Presión DE OperaciónLubricación Mantenimiento DE LA HerramientaCarga DEL Listón Carga DE LAS Herramientas Serie FAntes DE Manipular U Operar Esta Herramienta Mantenimiento DE LA Herramienta Neumática Presión Y Volumen DEL Suministro DE AirePiezas DE Repuesto Procedimiento DE Ensamblaje Para LOS SellosPara Reemplazar EL Pistón Mantenimiento DE LAS Herramientas DE LA Serie DWFP12569Corrección Solución DE ProblemasProblema Causa Garantie Limitée DE Trois ANS Introduction SommaireRemarque Alimentation EN AIR ET Connexions Instructions DE SécuritéChargement DE L’OUTIL FonctionnementOpération Caractéristiques DU DWFP12569Lubrification Entretien DE L’APPAREILChargement DE Sauterelles Chargement DES Outils DE LA Série FPression ET Volume DE L’ALIMENTATION D’AIR Maintenance DE L’OUTIL PneumatiquePièces DE Rechange Procédure DE Montage DES JointsPour Remplacer L’ENTRAINEMENT Pour Remplacer LE PistonDépannage Problème Cause Solution