Elation Professional 575H manual Lamp Optimization

Page 14

Design Par 575H™

4.Carefully insert the new lamp into the socket (Be sure to only use an approved lamp). Please remember the lamp should fit completely in the lamp socket.

5.Once the lamp has been inserted into the socket, gently slide the socket assembly back into place and secure with the large retaining thumbscrew.

6.Always be sure to optimize the lamp after lamp replacement.

Do not operate this device with open cover

Lamp Optimization

The lamp orientation and optimization must be adjusted after every lamp change. This procedure centers the lamp in the reflector. Proper optimization will increase lamp life and ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a lower deviation can cause damage to the lamp and/or lens.

The Design Par 575H™ lamp holder is aligned at the factory. However, due to slight imperfections in all lamps, fine adjustments will improve light performance. Please follow the procedure below for proper lamp optimization:

1.Using either a DMX controller or the control panel on the unit (see “SPOT” in the fixture menu on page 26), strike the lamp and focus the light on a flat surface (beam open, white, no gobo, no effect).

2.Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws labeled 1, 2, and 3 as illustrated on the next page. Turn one screw at a time to drag the hot-spot diagonally across the projected image. If you cannot detect a hot-spot, adjust the lamp until the light is even.

3.To reduce a hot-spot, pull the lamp in by turning all three screws clockwise a 1/4-turn

©Elation Professional®

14

Design Par 575H™

Image 14
Contents Design Par 575H Contents General Information Never open this fixture while in use Design Par 575H Safety Instructions Design Par 575H Features General Guidelines Fixture Overview Design Par 575H Design Par 575H Lamp Installation Instructions Installing or replacing the lampLamp Optimization Design Par 575H Mounting and Installation MountingMounting points Clamp Mounting Securing the Design PAR 575H Understanding DMX DMX-512 control connection DMX-512 connection with DMX terminatorFixture DMX addressing Design Par 575H Display LED Indicators Default settings shaded Fixture MenuLamp OFF Address Menu Setting/Changing the DMX AddressMain Menu Functions Test MenuAuto Play Menu RUNAudi ALL Rese Reset MenuLamp Menu ScanLamp Time MenuLife ClmpFine Menu Rpan MenuRtlt Menu Display Menu Degr MenuMIC Menu Laau Automatic lamp start with power Rdmx Fixture SettingsLaau Dlay Controller SettingsDlof Dfse Reload the original factory settingsSpot VER FeedFans Adju Edit MenuREC StepSC01 RUN Design Par 575H DMX Channel Traits DMX channel function and values Error Codes Design Par 575H Cleaning and Maintenance Disconnect from mains before starting maintenance operationYear Limited Warranty Design Par 575H Photometric Data Dimensional Drawings Circuit Schematic Technical Specifications Power supply Power consumptionDesign Par 575H Elation Professional Design Par 575H Elation Professional Elation Professional