Elation Professional 575H manual Run

Page 41

Design Par 575H™

indicates the time needed to run this scene.

10.Press ENTER to edit the time needed, the display shows “TXXX”, “XXX” represents the time needed to run this scene. For example, “T002” means scene 1 needs 0.4 seconds to run, “T-15” means this scene needs 3.0 seconds to run. Note: “XX” is always 0.2 seconds not one second.

11.Adjust the time needed by tapping the UP button.

12.Press ENTER to save the settings for the scene you are editing, the display will change to the next scene automatically.

13.Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes maximum.

14.Press MODE/ESC to exit and save your edited scene into the fixtures internal memory. The number of steps can be defined under “EDIT” and the scenes can be called up under “Run.” To run the scenes see page 30.

Editing procedure 2: Using an external controller.

1.Call up the first scene in your controller now.

2.Select “SC01” by pressing the UP or DOWN buttons.

3.Press MODE/ESC, the display shows “SC01”.

4.Press MODE/ESC, the display shows “C-01”.

5.Select "CEDT" by pressing the UP or DOWN buttons.

6.Press MODE/ESC, the display shows "OFF".

7.Press UP, the display will read "ON".

8.Press MODE/ESC, the display shows "SC02". You successfully downloaded the first scene.

9.Adjust the Step-time as described above.

10.Call up the second scene in your controller now.

11.Repeat steps 5-11 until all desired scenes are downloaded.

12.Press MODE/ESC to exit. The number of steps can be defined under “STEP” and the scenes can be called up under “RUN.”

RUN

- This function allows you to “RUN” the user-installed program. You can set the

©Elation Professional®

41

Design Par 575H™

Image 41
Contents Design Par 575H Contents General Information Never open this fixture while in use Design Par 575H Safety Instructions Design Par 575H Features General Guidelines Fixture Overview Design Par 575H Design Par 575H Installing or replacing the lamp Lamp Installation InstructionsLamp Optimization Design Par 575H Mounting Mounting and InstallationMounting points Clamp Mounting Securing the Design PAR 575H Understanding DMX DMX-512 connection with DMX terminator DMX-512 control connectionFixture DMX addressing Design Par 575H Display LED Indicators Fixture Menu Default settings shadedLamp OFF Main Menu Functions Setting/Changing the DMX AddressAddress Menu Test MenuAuto Play Menu RUNAudi Lamp Menu Rese Reset MenuALL ScanLife Time MenuLamp ClmpFine Menu Rpan MenuRtlt Menu Display Menu Degr MenuMIC Menu Laau Automatic lamp start with power Rdmx Fixture SettingsLaau Dlay Controller SettingsDlof Dfse Reload the original factory settingsSpot VER FeedFans Edit Menu AdjuStep RECSC01 RUN Design Par 575H DMX Channel Traits DMX channel function and values Error Codes Design Par 575H Disconnect from mains before starting maintenance operation Cleaning and MaintenanceYear Limited Warranty Design Par 575H Photometric Data Dimensional Drawings Circuit Schematic Power supply Power consumption Technical SpecificationsDesign Par 575H Elation Professional Design Par 575H Elation Professional Elation Professional