Elation Professional 575H DMX-512 control connection, DMX-512 connection with DMX terminator

Page 21

Design Par 575H™

DMX-512 control connection

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head (Please refer to the diagram below.). You can chain multiple moving heads together through serial linking. The cable needed should be two conductor, shielded cable with XLR input and output connectors that is specially designed for DMX data transmission. Always be sure to daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™.

DMX-512 connection with DMX terminator

You should always use a terminator on the last fixture to avoid erratic behavior. A terminator is a 90-120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a cable terminator (Elation part number Z-DMX/T) will decrease the possibilities of erratic behavior.

5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available fro Elation and most professional lighting retail stores. The following chart details a proper cable conversion.

©Elation Professional®

21

Design Par 575H™

Image 21
Contents Design Par 575H Contents General Information Never open this fixture while in use Design Par 575H Safety Instructions Design Par 575H Features General Guidelines Fixture Overview Design Par 575H Design Par 575H Installing or replacing the lamp Lamp Installation InstructionsLamp Optimization Design Par 575H Mounting Mounting and InstallationMounting points Clamp Mounting Securing the Design PAR 575H Understanding DMX DMX-512 connection with DMX terminator DMX-512 control connectionFixture DMX addressing Design Par 575H Display LED Indicators Fixture Menu Default settings shadedLamp OFF Main Menu Functions Setting/Changing the DMX AddressAddress Menu Test MenuPlay Menu RUN AudiAuto Lamp Menu Rese Reset MenuALL ScanLife Time MenuLamp ClmpRpan Menu Rtlt MenuFine Menu Degr Menu MIC MenuDisplay Menu Laau Automatic lamp start with power Fixture Settings LaauRdmx Controller Settings DlofDlay Reload the original factory settings SpotDfse Feed FansVER Edit Menu AdjuStep RECSC01 RUN Design Par 575H DMX Channel Traits DMX channel function and values Error Codes Design Par 575H Disconnect from mains before starting maintenance operation Cleaning and MaintenanceYear Limited Warranty Design Par 575H Photometric Data Dimensional Drawings Circuit Schematic Power supply Power consumption Technical SpecificationsDesign Par 575H Elation Professional Design Par 575H Elation Professional Elation Professional