Envision Peripherals IM1609 10, IM1609 08 Installation Steps, Mark Unit Position

Page 13

ENVISION CONSOLE INSTALLATION MANUAL

Installation Steps

Step 1: Unpack Equipment and Inspect for Damage

Step 2: Determine Equipment Location

Choose level flooring surface (Correctable with shims. Do not pitch towards drain.)

Location of wall support and fasteners required to secure chassis backplate.

Easy access for both installation and service.

Consider availability and ease of wiring, water piping and condensate drain.

No obstructions to block airflow in front of the unit.

Step 3: Mark Unit Position

Ensure that floor is level. If shims are required, make sure that the entire compressor compartment area is uniformly shimmed and that the backplate mounting height is increased by the thickness of the shims used.

Position backplate in desired equipment location. To further reduce the operating sound level of the unit, 1/8-inch thick rubber matting may be placed under the chassis to eliminate vibration on hard flooring surfaces. (Make sure back plate is level).

Mark and cut floor or wall penetrations for electrical wiring, water and condensate piping.

Optional Electrical Disconnect and Motorized Outside Air Damper

Mark and cut wall penetrations for field fabricated outside air duct sleeve.

Align mounting holes with backplate and attach with screws supplied.

Figure 1

1=<A=:31/07<3B 0/19>:/B3 =>B7=</:

4CA323:31B@71/: 27A1=<<31B=>B7=</:

E/::>3<3B@/B7=< 4=@E/B3@1=<<31B7=<

4:==@>3<3B@/B7=< 4=@E/B3@1=<<31B7=<

E/B3@ 7<

E/B3@ =CB

>B>:C5A =>B7=</:

0/::D/:D3A

=>B7=</:

=>B7=</:6=A3A

1=<23<A/B3 2@/7<:=1/B7=<

;=B=@7H32

2/;>3@

=>3<7<5

;=B=@7H32

2/;>3@

=>B7=</:

1=<A=:3 1/07<3B

1=<A=:3

16/AA7A

12

Image 13
Contents Envision Console Installation Manual Page Table of Contents NC C Model NomenclatureSafety Considerations General Installation InformationRefrigerant Systems Moving and StorageNCW09-18 Dimensional Data Flat Top CabinetConfiguration Dimensional Data Slope Top CabinetNCS09-18 Slope TopNCE09-18 Dimensional Data Extended Slope Top CabinetExt. Slope Top Dimensional Data Right Return Controls Detail  Dimensional Data Right Return ChassisDimensional Data Left Return Controls Detail # Dimensional Data Left Return ChassisMark Unit Position Installation StepsPipe Locations Provide Water and Condensate Drain ConnectionsChassis Installation Provide Line Voltage WiringFinal Electrical Connection Final Water ConnectionTop view Side view Field Converting ConsoleCleaning and Flushing System Cleaning and FlushingGround Source Loop System Checkout Water Quality Open Loop Ground Water SystemsElectrical Connections Microprocessor Remote Thermostat WiringAuxiliary Heat Ratings GeneralFan Performance Data Unit Electrical Data208-230-265/60/1 Wiring SchematicControl Module CCM w/EH Electronic Thermostat 208-230-265/60/1LED Display Mode Table Versatec Control EH & Remote Wall Thermostat 208-230-265/60/1 Schematic aPSC FX10 EH 208-230-265/60/1Envision Console Controls Standard CCM Control FeaturesOptional Versatec Microprocessor Control Features Control Tables for Optional Versatec Microprocessor Logic Board DIP Switch SettingsOptional FX10 Control Standard Features Control Timing & Fault Recognition DelaysOptional FX10 Microprocessor and BAS Interface Zone SensorsSequence of Operation Control and Safety Feature DetailsCompressor Fixed On Delay Time Random Start DelayCompressor Minimum On Delay Compressor Short Cycle Delay TimeControl Accessories Inputs & Outputs ConfigurationFX10 User Interface MUI Physical Layout  Info Status Temps Outputs SettingsLogin Required N2 Open LonWorks Point Description LonWorksBACnet Point Description BACNetAnalog Input Type BACnet VariablesAnalog Output Type Analog Value TypeMultistate Output Type Multistate Input TypeUnit Startup Notes Hydronic Loop Controller for Boiler/Tower InstallationsEmergency Electric Resistance Heat Electrical DisconnectBefore Powering Unit, Check The Following Unit Startup Checklist / Unit Startup StepsStartup Steps Unit Operating Limits Unit Operating ParametersSingle Speed Models Startup/Troubleshooting Form Pressure Drop Replacement Procedures Preventive MaintenanceWater Coil Maintenance Other MaintenancePage Envision Series Console

IM1609 10, IM1609 08 specifications

Envision Peripherals has carved a niche in the realm of advanced display technology, and its IM1609 10 and IM1609 08 models are no exception. These cutting-edge monitors are designed to meet a wide array of professional needs while delivering outstanding performance and visual clarity.

One of the standout features of the IM1609 10 is its impressive 16:9 aspect ratio and full HD resolution. This setup ensures that users receive crisp and vibrant visuals, whether they're working on intricate designs, analyzing data, or enjoying multimedia content. The IM1609 08 shares similar visual capabilities, making both models ideal for professionals in graphic design, video editing, and other visually intensive fields.

Both displays incorporate advanced LED backlight technology, which not only enhances color accuracy but also contributes to energy efficiency. Users can expect deeper blacks and brighter whites, resulting in a more dynamic visual experience. Furthermore, the IM1609 series features wide viewing angles, allowing multiple users to view the screen simultaneously without loss of quality or color distortion.

In terms of connectivity, the IM1609 10 and IM1609 08 come equipped with a range of ports, including HDMI, DisplayPort, and USB-C. This versatility ensures seamless integration with various devices, from laptops and desktops to media players and more. The USB-C port also allows for quick data transfer and charging options, catering to the needs of modern tech users.

Ergonomics is another key characteristic of the IM1609 series. With adjustable stands that allow for height, tilt, and swivel adjustments, users can customize their viewing experience for maximum comfort, reducing neck and eye strain during long working hours.

Additionally, the IM1609 monitors feature built-in blue light filters and flicker-free technology, which help to create a healthier viewing environment by minimizing eye fatigue. This consideration for user well-being is increasingly important in today’s tech-driven world, especially for professionals who spend significant time in front of screens.

Overall, Envision Peripherals’ IM1609 10 and IM1609 08 models represent the company’s commitment to blending performance, usability, and comfort into one seamless package. Whether for professional or personal use, these monitors deliver exceptional quality, making them a noteworthy addition to any workspace.