Chassis is normally configured with controls on right end and piping on left end (see Figure 3 top view). In this position panel number 1 would be positioned against wall or back plate. Unit may also be turned 180° against wall or back plate. In this position controls will be on left end and piping on right end panel number 2 would be positioned against wall or back plate. Chassis must be enclosed with an approved cabinet enclosure.

Figure 3

1

Top view

Side view

2

 

1.Remove 4 screws from front kick panel on cabinet.

2.Remove cabinet from chassis by lifting and sliding cabinet straight up.

3.Remove grille assembly from cabinet by removing 4 screws from brackets located on the bottom of the grille and door assemblies.

4.Replace grille/door assemblies into cabinet repositioning pieces

1, 2, and 3 into the locations directly opposite the original positions. Secure by replacing mounting brackets. (Note: Be sure that louvers on the grille assembly are facing the proper direction when replacing the grille section.)

5.Replace grille/frame assembly into cabinet, and secure by replacing mounting brackets.

6.Replace cabinet by sliding it down over the top of the chassis.

7.Remove tab on leg that extends into return air opening. When the grille side of the cabinet is flat against chassis there will be 4 holes that line up in the leg section. Only use 1 hole for alignment for opposite side of grille. (Note: The tab can be removed by twisting back and forth until it breaks off.)

8.Remove plastic strip from tab and replace on rough edge that the tab was removed from.

9.Replace screws in font kick panel to secure cabinet to chassis.

10.Mount filter bracket in designated opening area. (Note: The filter bracket will only fit in one direction if cabinet is installed properly.)

Figure 4

Depends on Cabinet Size

3

2

1

4

5

15

Image 16
Contents Envision Console Installation Manual Page Table of Contents Model Nomenclature NC CGeneral Installation Information Safety ConsiderationsRefrigerant Systems Moving and StorageDimensional Data Flat Top Cabinet NCW09-18Dimensional Data Slope Top Cabinet ConfigurationNCS09-18 Slope TopNCE09-18 Dimensional Data Extended Slope Top CabinetExt. Slope Top Dimensional Data Right Return Controls Detail Dimensional Data Right Return Chassis Dimensional Data Left Return Controls Detail Dimensional Data Left Return Chassis # Installation Steps Mark Unit PositionProvide Water and Condensate Drain Connections Pipe LocationsProvide Line Voltage Wiring Chassis InstallationFinal Electrical Connection Final Water ConnectionField Converting Console Top view Side viewCleaning and Flushing System Cleaning and FlushingGround Source Loop System Checkout Open Loop Ground Water Systems Water QualityMicroprocessor Remote Thermostat Wiring Electrical ConnectionsAuxiliary Heat Ratings GeneralUnit Electrical Data Fan Performance DataWiring Schematic 208-230-265/60/1CCM w/EH Electronic Thermostat 208-230-265/60/1 Control ModuleLED Display Mode Table 208-230-265/60/1 Schematic a Versatec Control EH & Remote Wall ThermostatFX10 EH 208-230-265/60/1 PSCStandard CCM Control Features Envision Console ControlsOptional Versatec Microprocessor Control Features Logic Board DIP Switch Settings Control Tables for Optional Versatec MicroprocessorOptional FX10 Control Control Timing & Fault Recognition Delays Standard FeaturesOptional FX10 Microprocessor and BAS Interface Zone SensorsControl and Safety Feature Details Sequence of OperationRandom Start Delay Compressor Fixed On Delay TimeCompressor Minimum On Delay Compressor Short Cycle Delay TimeInputs & Outputs Configuration Control AccessoriesInfo Status Temps Outputs Settings FX10 User Interface MUI Physical Layout Login Required N2 Open LonWorks LonWorks Point DescriptionBACNet BACnet Point DescriptionBACnet Variables Analog Input TypeAnalog Output Type Analog Value TypeMultistate Input Type Multistate Output TypeHydronic Loop Controller for Boiler/Tower Installations Unit Startup NotesEmergency Electric Resistance Heat Electrical DisconnectBefore Powering Unit, Check The Following Unit Startup Checklist / Unit Startup StepsStartup Steps Unit Operating Limits Unit Operating ParametersSingle Speed Models Startup/Troubleshooting Form Pressure Drop Preventive Maintenance Replacement ProceduresWater Coil Maintenance Other MaintenancePage Envision Series Console