Miller Electric ICE-27T, 375 X-TREME manual OM-225 216

Page 33

1

23

5

1

4

Item Part

No. No. Description

1183 427 Handle Assy, complete (1)

2171 248 Push Button Switch (1)

3228 405 Leads, 12 ft (1)

4203 119 Main Body (1)

5185 833 Switch Assembly w/spring (1)

190 220 Spring, trigger assembly

169 231 Grease, silicone (1)

225 615 Torch, replacement 12 ft (1)

See Figure 8-1for

additional consumable parts.

Figure 8-2. Torch, ICE-27T

NOTE

A complete Parts List is available on-liine at www.MillerWelds.com

To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-225 216 Page 29

Image 33
Contents Processes OM-225 216FDescription File Plasma CuttersFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsagePlasma Arc Cutting Hazards Cutting can cause fire or explosionFlying Sparks can cause injury Exploding Parts can injureARC Rays can burn eyes and skin Noise can damage hearingCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers LE Coupage présente un risque de feu ou d’explosion Signification des symbolesUNE Décharge Électrique peut entraîner la mort Identifie un message de sécurité particulierLE Bruit peut endommager l’ouïe Risque de blessure en casLES Fumées ET LES GAZ peuvent être dangereux LE Plasma D’ARC peut entraîner des blessuresDES Organes Mobiles peuvent provoquer des blessures DES Pieces Chaudes peuvent pro- voquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OUInformation sur les champs électromagnétiques Principales normes de sécuritéLE Coupage à L’ARC peut causer des interférence Consignes relatives aux stimulateurs cardiaquesSymbols And Definitions SpecificationsSpecifications For Torch Power Source Dimensions And Weight Torch Dimensions And WeightDuty Cycle And Overheating Connecting Work Clamp Connecting Gas/Air SupplyExtension Cord Data Electrical Service Guide For 240 VAC60 Hz Input Voltage 240 Input Amperes At Rated OutputConnecting 1-Phase Input Power For 240 VAC 460 mm Connecting Input PowerControls − OperationCutting Speed Trigger Safety LockSequence Of Operation When trigger is pressedExample Of Cutting Operation Pilot arc starts immediatelyOverload Protection Routine MaintenanceTurn Off Wrapper RemovalWrapper Check Bus Removing wrapper Wrapper Torx Screws Fine ThreadDC Bus Voltage Check Checking Or Replacing Filter Element Shield Cup Checking Torch Shield Cup Shutdown SystemChecking/Replacing Retaining Cup, Tip, And Electrode Turn Off power source before checking torch partsTorch And Work Cable Connections Torch ConnectionsWork Cable Connections OM-225 216 − Electrical Diagram 224 682-B Recommended Spare Parts Recommended Spare PartsOM-225 216 Page Support ServiceMiller Electric Mfg. Co Owner’s Record