1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Practices for Plasma Arc Cutting, American Welding Society Standard AWS C5.2, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from Global Engineering Docu- ments (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202.

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Bou- levard, Rexdale, Ontario, Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec- tion, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018.

Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000,website: www.nfpa.org).

OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Superin- tendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices−−phone for Region 5, Chicago, is 312−353−2220,website: www.osha.gov).

1-6. EMF Information

Considerations About Welding Or Cutting And The Effects Of Low Frequency Electric And Magnetic Fields

Welding or cutting current, as it flows through the welding or cutting cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power-frequency electric and magnetic fields is a human- health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following proce- dures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep cutting power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the cut as possible.

About Pacemakers:

Pacemaker wearers consult your doctor before welding/cutting or going near welding/cutting operations. If cleared by your doctor, then following the above procedures is recommended.

OM-225 216 Page 4

Image 8
Contents OM-225 216F ProcessesDescription File Plasma CuttersFrom Miller to You Table of Contents Page Symbol Usage Marks a special safety messagePlasma Arc Cutting Hazards Cutting can cause fire or explosionExploding Parts can injure Flying Sparks can cause injuryARC Rays can burn eyes and skin Noise can damage hearingCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Signification des symboles LE Coupage présente un risque de feu ou d’explosionUNE Décharge Électrique peut entraîner la mort Identifie un message de sécurité particulierRisque de blessure en cas LE Bruit peut endommager l’ouïeLES Fumées ET LES GAZ peuvent être dangereux LE Plasma D’ARC peut entraîner des blessuresDES Pieces Chaudes peuvent pro- voquer des brûlures graves DES Organes Mobiles peuvent provoquer des blessuresLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OUPrincipales normes de sécurité Information sur les champs électromagnétiquesLE Coupage à L’ARC peut causer des interférence Consignes relatives aux stimulateurs cardiaquesSpecifications For Torch Symbols And DefinitionsSpecifications Duty Cycle And Overheating Power Source Dimensions And WeightTorch Dimensions And Weight Connecting Gas/Air Supply Connecting Work ClampElectrical Service Guide For 240 VAC Extension Cord Data60 Hz Input Voltage 240 Input Amperes At Rated OutputConnecting 1-Phase Input Power For 240 VAC Connecting Input Power 460 mm− Operation ControlsTrigger Safety Lock Cutting SpeedWhen trigger is pressed Sequence Of OperationExample Of Cutting Operation Pilot arc starts immediatelyRoutine Maintenance Overload ProtectionWrapper Removal Turn OffWrapper Check Bus Removing wrapper Wrapper Torx Screws Fine ThreadDC Bus Voltage Check Checking Or Replacing Filter Element Checking Torch Shield Cup Shutdown System Shield CupTurn Off power source before checking torch parts Checking/Replacing Retaining Cup, Tip, And ElectrodeWork Cable Connections Torch And Work Cable ConnectionsTorch Connections OM-225 216 − Electrical Diagram 224 682-B Recommended Spare Parts Recommended Spare PartsOM-225 216 Page Service SupportOwner’s Record Miller Electric Mfg. Co