5.Turn the crank handle three full rotations (counting from the point of actual table move- ment so handwheel freeplay does not affect your count) to lower the table so the gauge blocks are below the pressure rollers, as shown in Figure 36.
Figure 36. Gauge blocks below pressure rollers.
Note: You may open the side covers to gain better access for the following adjustments. This is not required.
6.Turn a lower adjustment bolt on one side of a pressure roller clockwise to lower that end of the pressure roller until it touches the gauge block.
7.Repeat Step 6 for the opposite side of the same pressure roller.
8.Repeat Steps 6–7 with the second pressure roller. Each pressure roller should look like Figure 37 when properly adjusted.
Figure 37. Pressure rollers set correct distance
below bottom of sanding drum.
9.Tighten the jam nuts (Figure 34) to lock the adjustment.
Scale Pointer
Calibration
Tools Needed: | Qty |
Phillips Head Screwdriver. | ................................. 1 |
In order for the scale pointer to be accurate, it must be calibrated.
We recommend calibrating your scale pointer any time you adjust the drum height or table lift screws.
To calibrate the scale pointer:
1.Sand a workpiece with the drum sander and measure the thickness of the sanded workpiece.
2.Loosen the screw that secures the scale pointer and adjust it to the thickness of the workpiece.
Model G0459/G0459P (Mfg. 7/11+)