Grizzly G0459P owner manual Removal/Replacement, Pulley Alignment, To adjust V-belt tension

Page 33

To adjust V-belt tension:

1.DISCONNECT POWER TO THE SANDER!

2.Open the rear panel.

3.Loosen the motor mount bolts and raise or lower the motor bracket, as shown in Figure 26, to loosen or tighten the V-belt.

4.Tighten the motor mount bolts and replace the rear panel.

Motor

 

Plate

 

Bracket

Bolts

 

Figure 26. V-belt tension controls.

Removal/Replacement

Replace the V-belt if you notice fraying, cracking, glazing, or any other damage. A worn/damaged V-belt will not provide optimum power transmis- sion from the motor to the drums.

V-belt removal and replacement is simply a matter of loosening the V-belt, rolling it off of the pulleys, replacing it, and re-tensioning it.

Model G0459/G0459P (Mfg. 7/11+)

Pulley Alignment

Pulley alignment is another important factor in power transmission and belt life. The pulleys should be parallel to each other and in the same plane (coplaner) for optimum performance.

Each pulley can be adjusted by loosening the set screws that secure the pulley to the shaft, sliding the pulley in/out, and retightening the set screws to lock the pulley in place.

To align the pulleys:

1.DISCONNECT POWER TO THE SANDER!

2.Remove the right handle and side panel.

3.Remove the V-belt.

4.Place a straightedge across the face of the motor pulley and drum pulley to check the alignment. The straightedge should sit evenly on the top and bottom part of both pulleys, as shown in Figure 27.

Figure 27. Checking pulley alignment with a

straightedge.

5.Adjust the pulleys as necessary until they are all coplanar with each other.

6.Re-install the side panel and handle.

-31-

Image 33
Contents Drum Sander Ss ,EAD from Leadbased PAINTS Table of Contents Manual Accuracy IntroductionContact Info Machine DescriptionFront view, Model G0459 Identification$&+,1$7$ Drum Information $&+,1$7$ Conveyor Feed Rate 47 17.3 FPM Safety Instructions for Machinery SafetyZghWZXdbZVYhigVXidc# Children & BYSTANDERS. @ZZe XaYgZcAdditional Safety for Drum Sanders Availability Power SupplyFull-Load Current Rating Circuit RequirementsExtension Cords Grounding & Plug RequirementsMinimum Gauge Size 14 AWG 50 ftNeeded for Setup SetupUnpacking InventorySite Considerations Installing Crank Handle MountingComponents and Hardware Needed Qty Connecting Power Power ConnectionDisconnecting Power Dust CollectionRecommended Adjustments Test RunTo test run the machine Operation Overview OperationsBasic Controls Disabling & Locking SwitchStock Inspection Requirements Sanding TipsTo set the depth of cut Depth of CutTo adjust the conveyor speed Variable Speed SandingTo sand a workpiece Choosing Sandpaper Paper ReplacementGrit Class Usage To change sandpaperG4679-Anti-Static Grounding Kit AccessoriesPRO-STICKSanding Pad Size ModelCleaning MaintenanceSchedule LubricationPillow Block Bearings Service TroubleshootingMotor & Electrical Sanding Operations Drums Belt Service Gauge BlocksTension To adjust V-belt tension Removal/ReplacementPulley Alignment To align the pulleysTensioning Conveyor Tensioning TrackingTracking To tension the conveyorDrum parallel to conveyor belt Model G0459/G0459P Mfg /11+ Drum AdjustmentsDrum perpendicular to feed direction To adjust the pillow block bearingsTo adjust the pressure rollers to the factory setting Factory SettingPressure Roller HeightScale Pointer Calibration Tools Needed Qty Phillips Head ScrewdriverTo calibrate the scale pointer Table Lift Screws To adjust the table lift screwsTo replace the conveyor belt Conveyor Belt ReplacementTo Step Drum sander disassembledBrass Shims IVWaZ To replace the motor brushes Changing Motor BrushesWiring Safety Instructions WiringCapacitor Feed motor110 VAC Wiring DiagramFrame PartsDescription Frame Parts ListDescription DrumConveyor Label Placement Conveyor Parts List10. 8dbbZcih Warranty Card99.$5342!, .# 0//88 %,,.!- 7!  Warranty and Returns Order Hours a DAY