Schumacher SEM-1562A owner manual Operating Instructions, Charging

Page 10

NOTE: See the Operating Instructions section for a complete description of the charger modes.

12.OPERATING INSTRUCTIONS

This battery charger must be properly assembled in accordance with the assembly instructions before it is used.

Charging

1.Ensure that all of the charger components are in place and in good working condition, for example, the plastic boots on the battery clips.

2.Connect the battery following the connection instructions described in Using the Quick-Connect Cable Connectors section.

3.Connect the AC power following the precautions listed in Section 8. Make sure to place the charger on a dry, non-flammable surface, such as metal or concrete.

4.If you’ve connected everything correctly, the CHARGING (yellow) LED should be lit, indicating that the charger is

charging. If the CHARGING (yellow) LED does not light, check the connections or have the battery checked/replaced.

5.To disconnect, reverse the procedure.

NOTE: This charger is equipped with an auto-start feature. It will not supply current to the battery clips until a battery is properly connected. Unlike traditional chargers, the clips will not spark if touched together.

Using the Quick-Connect Cable Connectors

NOTE: Never connect the clamp and ring terminal connectors together for use in other applications, such as external battery or other power source charging, or to extend the output cable length, as reverse polarity and/or overcharge conditions will occur.

50 Amp Battery Clips:

1.Connect the end of the charger output cable to the end of the 50 amp battery clips cable.

2.Follow the steps in sections 6 and 7 to connect the output clips to the battery.

3.After a good electrical connection is made to the battery, plug the power cord into a grounded 120V AC electrical wall outlet.

• 9 •

Image 10
Contents Do not Return this Product to the Store ¡NO LO Devuelva este producto a LA TiendaImportant Safety Instructions Save These Instructions Risk of Electric Shock or FireRisk of Explosive Gases Personal Precautions Risk of Explosive Gases Charger Location Risk of Explosion Contact with Battery Acid DC Connection Precautions Page Grounding and ac power cord connections Control Panel FeaturesAssembly Instructions ConnectedOperating Instructions Using the Quick-Connect Cable Connectors Amp Battery ClipsCharging Desulfation Mode Permanent Ring ConnectorsAutomatic Charging Mode Aborted ChargeMaintaining a Battery Maintain Mode Float-Mode MonitoringCalculating Charge Time Maintenance Instructions Battery SIZE/RATING Charging TimeStorage Instructions Troubleshooting Problem Possible Cause REASON/SOLUTION Problem Possible Cause REASON/SOLUTION Before Returning for RepairsSpecifications Replacement PartsSchumacher Electric Corporation Customer Service Do not Return this Product To the StoreMail To ELDPTI ONI RiveD Business Center Mount ProspectPrograma DE Registro DE 2-AÑOS DE Garantía Limitada IrigaseD aEL Riesgo DE Descarga Eléctrica O Incendio Page Riesgo DE Gases Explosivos Precauciones Personales Riesgo DE Gases ExplosivosPage Precauciones DE Conexión EN CC Page Page Conexiones a tierra y energía de CA EL Riesgo DE Descarga Eléctrica IncendioLED Connected CaracterísticasInstrucciones DE Montaje LED ChargingCarga LED Charged cargado verde encendido Indica queInstrucciones DE Operación USO DE Conectores DE Cables DE Conexión RápidaModo de carga automática Pinzas De Bateria De 50 AmpsConectores Permanentes De Argolla Carga anuladaModo de mantenimiento Monitoreo a modo de flote Modo de desulfataciónFinalización de la carga Mantenimiento de la batería13. Cálculo DE Tiempo DE Carga TAMAÑO/ÍNDICE DE LA Batería Tiempo DE CargaInstrucciones DE Mantenimiento Instrucciones DE AlmacenajeLocalización Y Solución DE Problemas LED Antes DE Devolver a ReparacionesEspecificaciones RepuestosPage LA Tienda