Maintain Mode (Float-Mode Monitoring)
When the CHARGED LED is lit, the charger has started Maintain Mode. In this mode, the charger keeps the battery fully charged by delivering a small current when necessary. If the charger has to provide its maximum maintain current for a continuous 12 hour period, it will go into Abort Mode (see Aborted Charge section). This is usually caused by a drain on the battery, or the battery could be bad. Make sure there are no loads on the battery. If there are, remove them. If there are none, have the battery checked or replaced.
Maintaining a Battery
The Schumacher
NOTE: The maintain mode technology utilized in Schumacher’s maintainers allows you to safely charge and maintain a healthy battery for extended periods of time. However, problems with your battery, electrical problems in your vehicle, improper connections or other unanticipated conditions could cause excessive current draws, as such, occasionally monitoring your battery and the charging process is recommended.
13.CALCULATING CHARGE TIME
Find your battery’s rating on the chart below, and note the charge time given. The times given are for batteries with a 50% charge prior to recharging. Add more time for severely discharged batteries.
CCA = Cold Cranking Amps AH = Amp Hour
RC = Reserve Capacity
MAINTAIN ONLY = See Maintaining a Battery in the “Operating Instructions” section.
• 11 •