English
Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become hot should be cooled for a while before being recharged.
| Table 6 |
|
|
Rechargeable battery | Temperatures at which the battery can be recharged |
|
|
EB1820L | 32°F — 113°F (0°C — 45°C) |
|
|
BEFORE USE
Check the work area to make sure that it is clear of debris and clutter.
Clear the area of unnecessary personnel. Ensure that lighting and ventilation is adequate.
PRIOR TO OPERATION
1.Mounting the blade
This unit employs a detachable mechanism that enables mounting and removal of saw blades without the use of a wrench or other tools.
(1)Turn on and off the switching trigger several times so that the lever can jump out of the front cover completely. Thereafter, turn off the switch and remove the battery. (Fig. 9)
Lever
Front cover
CAUTION: Be absolutely sure to keep the switch turned off and the battery removed to prevent any accident.
(2)Push the lever in the direction of the arrow mark shown in Fig. 10 marked on the lever. (Fig. 10)
(3)Insert the saw blade all the way into the small slit of the plunger tip with the lever pushing. You can mount this blade either in the upward or downward direction. (Fig. 11, Fig. 12)
(4)When you release the lever, the spring force will return the lever to the correct position automatically. (Fig. 13)
(5)Pull the back of the saw blade two or three times by hand and check that the blade is securely mounted. When pulling the blade, you will know it is properly mounted if it clicks and the lever moves slightly. (Fig. 14)
CAUTION: When pulling the saw blade, be absolutely sure to pull it from the back. Pulling other parts of the blade will result in an injury.
Fig. 9
Lever
Fig. 10
Blade
Slit of plunger
Fig. 11
21