P 26/ 26
Wiring diagram in Handle L
LS0714L (with laser marker)
When connecting power supply cord with electrical |
| Powers supply cord |
| ||||
|
|
|
|
|
|
| |
parts in handle, strip the power supply cord to expose |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
50mm up to 70mm of one inner lead wire for | Terminal block |
|
|
|
|
|
|
connecting with Terminal as illustrated to right. |
|
|
|
| |||
|
|
| |||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Printed wiring board
Rib D
Main switch
Noise suppressor Connector
Receptacles for connecting to laser switch
Power supply cord
Rib C
Rib B Rib A
Punched hole
Terminal block
Motor housing
Insulated connector | Transformer |
|
1Pass the thin lead wires (black and red) with connector of wiring board through the punched hole.
2The following lead wires for connecting insulated connector should be put into lead wire holder so thati nsulated connector does not rise from handle L.
*Lead wire (red) to switch
*Lead wire (blue) to transformer
*Field lead wire (orange)
*Lead wire (white) of noise suppressor
3Transformer must be mounted so that lead wires (black and white) face the side of handle R and are in the side of motor housing.
If these lead wires go over Rib A/B, these are pinched between the Rib A/B and handle R.
Therefore, fix them with full attention.
4When putting the lead wires into lead wire holders, the thin lead wires have to be put under the thick lead wires so as not to rise from the original position.
5Power supply cord should be put so that its sheath portion is between Rib C and the wall of housing L.
6When putting handle R on housing L,
be careful not to go over lead wires on Rib D. Otherwise it will happen pinching.
7When connecting receptacles to laser switch,
be sure to face its
The receptacle with black colored lead wire should be close to O mark on the laser switch.
See illustration below.
| ||
Handle R |
| |
Lead wire | Laser | |
(blue) | ||
| switch | |
Lead wire | Receptacles | |
(black) | ||
|