Milwaukee 6562 manual Assembly, Inserting the Plunger Rod

Page 4

ASSEMBLY

WARNING!

Always lock trigger or remove battery pack before changing or removing acces- sories. Only use accessories specifically recommended for this tool. Others may be hazardous.

Installing Tube Holder Assembly (Cat. No. 6562-23) (Fig. 4)

Fig. 4

Plunger rod

6562-23

 

Washer (black)

 

 

 

 

Washer (Steel)

 

 

Barrel nut

 

 

Plunger

 

 

Screw

Inserting the Plunger Rod

Always lock the trigger or remove the battery pack before inserting the plunger rod. Do not run the tool to pull the plunger rod through

3. Insert the plunger rod from the rear of

the tool. It may be necessary to wiggle

the plunger rod slightly while pushing it

Tube holder

the tool, this will damage the tool and rod. Manually push the plunger rod through the tool, as follows:

1.Press in and hold rod release trigger.

2.Grasp the plunger rod handle. The teeth on the plunger rod should point toward the left and slightly down.

through the tool.

NOTE: Keep the plunger rod clean. Retract- ing or inserting a plunger that is covered with material may damage the internal parts of the tool.

1.

Lock trigger or remove battery pack.

2.

Press in and hold rod release trigger.

3.

Grasp plunger rod handle and pull

 

plunger rod back until the rod tip is just

 

inside of tool.

4.

Release rod release trigger.

5.

Position washer (black) onto nose of

 

tool. The side with the larger collar fits

 

inside the tool.

7.

Place washer (steel) between the tube

 

holder and barrel nut. Thread barrel nut

 

into nose of the tool. Tighten securely

 

using the wrench provided.

8.

Press rod release trigger and push

 

plunger rod forward to access the tip of

 

the rod.

9.

Attach plunger to the plunger rod, as

 

shown (Fig. 4). Tighten the screw se-

 

curely.

Installing 10oz Tube Holder Assembly (Cat. No. 6562-21) (Fig. 3)

Fig. 3

Plunger rod

Plunger

 

 

Screw

Tube holder

 

 

Barrel nut

 

 

Frame cap

Tube holder

6562-21

 

6. Install tube holder over washer.

10. To remove tube holder, reverse proce-

WARNING!

To reduce the risk of injury, keep hands out of the plunger area of the tool. Fingers can be pinched between the tube holder and the plunger.

Installing Caulk or Adhesive Tube

1.Lock trigger or remove battery pack.

2.Press in and hold rod release trigger.

3.Grasp plunger rod handle and pull plunger rod back until the rod tip is just inside of tool.

4.Release rod release trigger.

5.The frame cap, barrel nut, and tube holder are provided pre-assembled.

6.Thread barrel nut into the nose of the tool. Tighten securely using the wrench provided.

7.Press rod release trigger and push plunger rod forward to access the tip of the rod.

8.Attach plunger to the plunger rod, as shown (Fig. 3). Tighten the screw se- curely.

9.To remove tube holder, reverse proce- dure.

1.Lock trigger or remove battery pack.

2.Cut nozzle of tube at an angle and size per manufacturer's recommendation to suit the job. A smaller nozzle diameter requires more force to push the caulk and reduces battery life.

3.Break inner seal of tube using a long nail or piece of wire. If the inner seal is not broken, the caulk material may be forced out the rear end of the tube and damage the tool.

NOTE: Before using a partially filled tube, remove any hardened material with a long nail or piece of wire.

4.Press in and hold rod release trigger.

5.Grasp plunger rod handle and pull plunger rod back to allow the caulk tube to fit inside carriage frame.

6.Insert caulk tube into carriage frame.

7.Push plunger rod handle forward until the plunger is against the caulk tube.

8.Release rod release trigger.

6

7

Image 4
Contents Pour étendre la durée de vie de la batterie To extend battery pack life Para extender la duración de la batería Power Tool USE and Care Battery Tool USE and CareWork Area Safety Electrical SafetyBattery Pack Care and USE Inserting Battery Pack into ToolFunctional Description Perform its intended function i.e., drillingInstalling 10oz Tube Holder Assembly Cat. No -21 Fig AssemblyInserting the Plunger Rod Operation Maintenance Accessories Five Year Tool Limited WarrantyConserver CES Instructions Sécurité DU Lieu DE TravailUtilisation ET Entretien DE L’OUTIL Électrique Utilisation ET Entretien DE LA BatterieEntretien Règles DE Sécurité SpécifiquesDescription Fonctionnelle Tension c.d. seulNo de cat Volts 6562 Série La capacité est maintenueAvertissement Montage DE Loutil Retrait de la batterie de l’outilIntroduction de la batterie dans l’outil Insertion de la mècheInstallation de l’ensemble cylindrique No de cat -24 Fig Installation du porte-tube de 851 g 30 oz No de cat -23 FigInstallation du tube de colle ou de cal- feutrage Maniement Maintenance Avertissement Accesoires Avertissement Garantie Limitée DE ’OUTIL DE Cinq ANSGUA0RDE Estas Instrucciones Seguridad EN EL Área DE TrabajoMantenimiento USO Y Cuidado DE LAS HER Ramientas EléctricasReglas Especificas DE Seguridad USO Y Cuidado DE LA Batería ¡ADVERTENCIAAsegurar que se mantiene la capacidad En los que los bornes se pueden corroerIntroducción del vástago de percutor Ensamblaje DE LA HerramientaInstalación del tubo de adhesión y calafateo Instalación del paquete tipo salchicha Instalación del conjunto del cilindro Cat. No -24Operacion Mantenimiento ¡ADVERTENCIAGarantía Limitada DE Cinco Años Accesorios ¡ADVERTENCIAMilwaukee 800.729.3878800.729.3878 fax West Lisbon Road Brookfield, Wisconsin, U.S.A