Section 7 – Troubleshooting
Problem | Possible Cause | Possible Solution | |
| Faulty Fluorescent | Check the fluorescent tube for darkened or cracked | |
Marquee Lamp is | Tube | end. Replace the Fluorescent tube if it looks worn. | |
Faulty or | Faulty Fluorescent | Verify the fluorescent tube pins make a good | |
Intermittent | connection with the lamp fixture. Check the ballast for | ||
| Fixture | proper operation. | |
|
| ||
| Incorrect Setting in | Check Credits per Game and Credits per Continue | |
Improper Number | Operator Menu | settings from Operator Menu. | |
of Credits given |
| Turn off the cabinet. Verify that all the wires are firmly | |
when Coins or Bills | Faulty Wiring | connected to each coin mech or Bill Validator. Verify | |
are Inserted | that no wires are frayed or improperly shorting to | ||
|
| ground. | |
| Faulty Coin Mech | Verify the coin mech is not jammed. Make sure the coin | |
Game will not | mech is properly aligned and latched to the coin door. | ||
| |||
accept Coins or |
| Verify the bill validator is powered on and working. If | |
Bills | Faulty Bill Validator | the bill validator is faulty, it will usually blink an error | |
|
| code on the inside of the coin door. |
gvrSX™ Conversion System Manual |
|
Page 42 of 48 |