2INTERNAL LINKS AND SWITCHES

2.1REMOVING THE PROFILE CONTROLLER FROM ITS HOUSING

CAUTION: Before removing the instrument from its housing, ensure that all power has been removed from the rear terminals.

To withdraw the instrument from its housing, simply grip the side edges of the front panel (there is a finger grip on each edge) and pull the instrument forwards. This will release the instrument from its rear connectors in the housing and will give access to the instrument PCBs. Take note of the orientation of the instrument for subsequent replacement into the housing.The positions of the PCBs in the instrument are shown in Figure 2-1.

RS485 Com m unic a tions Op tion PC or

Re m ote Run/Hold Op tion PCB

Outp ut 3 Op tion PCB

(Relay, SSR Drive,

Solid State or DC Output)

Outp ut 3 Link Jum p e rs (DC Output only)

Outp ut 2 Link Jum p e rs (DC Output only)

Outp ut 2 Op tion PCB

DC Outp ut 1 PCB (if fitte d )(Relay, SSR Drive, Solid State or DC Output)

Figure 2-1 PCB Positions

S077-2

Volume I

2-1

Image 12
Contents Page Page RAMP/SOAK Profile Volume Installation & Configuration Instructions Volume Operating InstructionsContents Unpacking Procedure PANEL-MOUNTING the ControllerConnections and Wiring Rear Terminal Connections Mains Line Input 2 24V Nominal AC/DC SupplyThermocouple Input RTD InputsLinear Inputs Remote Run/Hold InputRelay Outputs SSR Drive OutputsDC Outputs 11 RS485 Serial Communications LinkInternal Links and Switches Removing the Profile Controller from ITS HousingRemoving the Output 2/Output 3 Option PCBs Replacing the Instrument in ITS Housing REMOVING/REPLACING the Output 2/OUTPUT 3 Option PCBsSelection of Input Type and Output 1 Type Input TypePrimary Output Output 1 Type CPU PCB Relay/SSR Drive/Solid State OutputOutput 2 TYPE/OUTPUT 3 Type Entry Into Configuration Mode Hardware Definition CodeConfigurat ion Mode Wit h Hardw are Definit ion Code displayedOption Selection Hardware Definition Code Input/Output Type SelectionConfiguration Mode Parameters Wit h Hardw are Definit ion Code displayedParameter AL1 OFF, AL2 OFF Parameter Page Exit from Configuration Mode Base Mode Controller SET-UP Mode Program Definition Mode CREATING/EDITING a ProgramModbus Communications Alphabetic IndexBase Mode Display Sequence no Program RunningStarting a Program Putting a Program in HoldReleasing a Program from Hold Aborting a ProgramDisplay Sequence Program Running Read Only whilst Program is running/heldRaPID Control Feature PRE-TUNE FeatureEngaging Both PRE-TUNE and RaPID Features Indication of PRE-TUNE and RaPID StatusRaPID Status when Viewing the Hardware Definition Code Hardware Definition Code has the following significanceManual Control Press till front panel shows Press or to change display toController SET-UP Mode Lower display = Parameter Function Adjustment Range Default Value Parameter DetailsON/OFF Parameter Function Adjustment Range Default Value Power Alarm Operation Deviation Exit from Controller SET-UP Mode When this display showsProgram Definition Mode CREATING/EDITING a Program EntryCreating a Program Basic GuidelinesDefining Segments Rate Mode To make a Soak segmentDefining Segments Time Mode Program Options Guaranteed Soak Band T p o i n tSegment Event Status Press key To display Default Values and Adjustment Ranges Exit from Program Define ModeIntroduction Modbus Functions SupportedMessage Formats Read Coil Status Read n Bits 01/02 CRC16Read Holding Registers Read n Words 03/04 Force Single Coil Write 1 BitPreset Single Register Write 1 Word 06 B Loopback Diagnostic TestPreset Multiple Registers Write n Words 16 B Error and Exception Responses CRC16 CalculationReversed BIT Order Used Parameter Numbers Bit Parameters Controller Status ByteWord Parameters Controller ParametersInstrument ID Parameters Volume O077-4 Profiler Commands Profiler Status ByteUniversal Input GeneralInput Range Remote RUN/HOLD Input Option Output RelaySSR Drive/TTL Solid StateTypes Available Relay, SSR drive, solid state and DC Solid State SSR Drive/TTL Alarm Control Loop ControlPerformance Reference ConditionsPerformance Under Reference Conditions S077-A Volume Environmental See PerformancePhysical Appendix B Summary of Displays Program Define Mode Parameters Configuration Mode Parameters AppendixC RaPID Control Feature AT OFF Alphabetical Index S077-IDX Volume Making a Soak Segment S077-IDX Volume Unpacking Procedure Word Parameters II/4-8