Omega CN1166 manual Rear Terminal Connections

Page 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

RECOMMENDEDMODEOF

 

 

-

 

10N or +

 

SeeSubsection1.3.1 or 1.3.2 (as

 

 

 

 

 

 

24VDC*

 

REMOTE

Output 1isalwaysthe primary control (HEAT)output -relay,SSR drive,solid

 

 

 

 

POWER CONNECTION

 

r

 

 

appropriate)for fuseratings.

 

 

 

 

terminals. * Option

 

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN/HOLD

 

 

 

 

 

L

 

 

 

 

 

 

V

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

/60

 

 

 

 

 

 

 

 

 

 

 

 

Top of Controller

Noexternalconnections

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

tobemadetothese

-264V

/60Hz

 

RS485

state orDC.

 

 

 

 

 

 

 

 

 

SERIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

96

50

 

COMMS.

 

 

 

 

 

 

L

N

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

8

9

10

11

12

 

 

 

 

 

 

OUTPUT 3

Relay

N/C C N/O

 

 

Solid State

 

 

DC/SSRDrive

16 17 18

 

 

 

 

 

 

13 14 15

DC/SSRDrive

Solid State

N/O C N/C

Relay

OUTPUT 2

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

5

6

 

 

 

 

 

 

 

 

 

 

drive,solid state orDC),alarm output,

Event output orProgram Active output

 

Output 3isused eitherasalarm output

 

recorderoutput (DC only forSPorPV)

 

 

 

 

 

 

 

RTD

 

 

 

 

 

 

 

 

Output 2isused asSecondary

Control(COOL)output (relay,SSR

 

(relay,SSR drive orsolid state)or

DC/SSR Dr iv e

 

 

 

 

 

 

 

 

 

 

 

 

(relay,SSR drive orsolid state)

 

 

 

 

 

 

 

The rm oc oup le

 

 

 

 

 

 

 

So lid

St a t e

 

 

 

Line a r (V/m V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line a r (m A)

 

 

 

 

 

 

 

N/O

 

C

N/C

UNIVERSAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

 

 

Re la y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT 1

 

 

 

 

 

 

 

 

 

Figure 1-4 Rear Terminal Connections

S077-1

Volume I

1-3

Image 8
Contents Page Page RAMP/SOAK Profile Volume Installation & Configuration Instructions Volume Operating InstructionsContents Unpacking Procedure PANEL-MOUNTING the ControllerConnections and Wiring Rear Terminal Connections Mains Line Input 2 24V Nominal AC/DC SupplyThermocouple Input RTD InputsLinear Inputs Remote Run/Hold InputRelay Outputs SSR Drive OutputsDC Outputs 11 RS485 Serial Communications LinkInternal Links and Switches Removing the Profile Controller from ITS HousingRemoving the Output 2/Output 3 Option PCBs Replacing the Instrument in ITS Housing REMOVING/REPLACING the Output 2/OUTPUT 3 Option PCBsSelection of Input Type and Output 1 Type Input TypePrimary Output Output 1 Type CPU PCB Relay/SSR Drive/Solid State OutputOutput 2 TYPE/OUTPUT 3 Type Entry Into Configuration Mode Hardware Definition CodeConfigurat ion Mode Wit h Hardw are Definit ion Code displayedOption Selection Hardware Definition Code Input/Output Type SelectionConfiguration Mode Parameters Wit h Hardw are Definit ion Code displayedParameter AL1 OFF, AL2 OFF Parameter Page Exit from Configuration Mode Base Mode Controller SET-UP Mode Program Definition Mode CREATING/EDITING a ProgramModbus Communications Alphabetic IndexBase Mode Display Sequence no Program RunningStarting a Program Putting a Program in HoldReleasing a Program from Hold Aborting a ProgramDisplay Sequence Program Running Read Only whilst Program is running/heldRaPID Control Feature PRE-TUNE FeatureEngaging Both PRE-TUNE and RaPID Features Indication of PRE-TUNE and RaPID StatusRaPID Status when Viewing the Hardware Definition Code Hardware Definition Code has the following significanceManual Control Press till front panel shows Press or to change display toController SET-UP Mode Lower display = Parameter Function Adjustment Range Default Value Parameter DetailsON/OFF Parameter Function Adjustment Range Default Value Power Alarm Operation Deviation Exit from Controller SET-UP Mode When this display showsProgram Definition Mode CREATING/EDITING a Program EntryCreating a Program Basic GuidelinesDefining Segments Rate Mode To make a Soak segmentDefining Segments Time Mode Program Options Guaranteed Soak Band T p o i n tSegment Event Status Press key To display Default Values and Adjustment Ranges Exit from Program Define ModeMessage Formats IntroductionModbus Functions Supported Read Coil Status Read n Bits 01/02 CRC16Read Holding Registers Read n Words 03/04 Force Single Coil Write 1 BitPreset Multiple Registers Write n Words 16 B Preset Single Register Write 1 Word 06 BLoopback Diagnostic Test Error and Exception Responses CRC16 CalculationReversed BIT Order Used Parameter Numbers Bit Parameters Controller Status ByteWord Parameters Controller ParametersInstrument ID Parameters Volume O077-4 Profiler Commands Profiler Status ByteUniversal Input GeneralInput Range Remote RUN/HOLD Input Option Output RelaySSR Drive/TTL Solid StateTypes Available Relay, SSR drive, solid state and DC Solid State SSR Drive/TTL Alarm Control Loop ControlPerformance Under Reference Conditions PerformanceReference Conditions S077-A Volume Physical EnvironmentalSee Performance Appendix B Summary of Displays Program Define Mode Parameters Configuration Mode Parameters AppendixC RaPID Control Feature AT OFF Alphabetical Index S077-IDX Volume Making a Soak Segment S077-IDX Volume Unpacking Procedure Word Parameters II/4-8