Agilent Technologies 6050A, 6051A manual Controls and Indicators Description

Page 50

Item

3Electronic Load Status Annunicators

4 GPIB Status Annunicators

5 SYSTEM Keys

Table 4-1. Controls and Indicators (continued)

Description

CC-Indicates the selected channel is in the constant current (CC) mode.

Note that Figure 4-1 illustrates that channel 1 is in the CC mode (CC annunciator is on).

CR-Indicates the selected input channel is in the constant resistance (CR) mode.

CV-Indicates the selected input channel is in the constant voltage (CV) mode.

Tran-Indicates that transient operation is enabled for the selected input channel.

Unr-Indicates that the selected input channel is unregulated (applies only in the CC mode and in the middle and high ranges of the CR mode).

Prot-Indicates when channel protection features (CC, OV, OP, OT, etc.) are active on any channel.

Err-Indicates that remote programming error(s) have occurred.

Shift-Indicates that the shift key, bottom key (blue) in SYSTEM group, was pressed.

Rmt-Indicates that the Multiple Electronic Load is in the GPIB remote state. In the remote state, the only front panel key that will function is the Local key.

Addr-Indicates that the Multiple Electronic Load is addressed to talk or to listen over the GPIB.

SRQ-Indicates that the Multiple Electronic Load is requesting service over the GPIB; i.e., the service request line (SRQ) is active.

- Returns the Multiple Electronic Load from remote (computer) control to local (front panel) control.

- Displays the Multiple Electronic Load’s GPIB address. You can change the address using the numeric entry keys. You cannot query or change the address remotely (over the GPIB).

(shifted address key) - Displays error codes that resulted from remote programming.

- Used in conjunction with the ENTRY keys to recall the saved settings of all channels from the specified location (Recall 0 through Recall 7). Recall 7 recalls the factory default settings.

(shifted Recall key) - Used in conjunction with the ENTRY keys to save all of the present settings (mode, current, resistance, voltage, etc.) of all channels in the specified register (SAVE 0 thru SAVE 6). The settings in locations 1 thru 6 will be lost when ac power is cycled. However, SAVE 0 will cause the settings to be stored in non-volatile memory; and, the next time the Multiple Electronic Load is turned on, these settings will become the power on settings.

(blue shift Key) - Activates shifted key functions (e.g., Error, Save, Slew, etc.). The Shift annunciator goes on when this key is pressed.

50 Local Operation

Image 50
Contents Operating Manual Certification Safety Summary Herstellerbescheinigung Safety SummarySymbol Description Manufacturer’s DeclarationPrinting History Page Table of Contents Installation Local OperationCalibration Considerations for Operating in Constant Resistance ModeRemote Operation Page General Information What’s In This ManualOptions Safety Requirements SpecificationsDimensions Page Introduction Operation OverviewRemote Programming Local/Remote ControlFront Panel Description Modes of Operation Extended Power OperationProgrammable Features Triggered Current Level Constant Current CC ModeImmediate Current Level Software Current Limit Constant Resistance CR ModeTransient Current Level Slew RateTriggered Resistance Level Constant Voltage CV ModeImmediate Resistance Level Transient Resistance LevelTransient Operation Triggered Voltage LevelTransient Voltage Level Pulsed Transient Operation Hpsl Command DescriptionContinuous Transient Operation Sets pulse width to 1 millisecond Selects the external trigger inputSelects pulsed transient operation Selects toggled operation Triggering a preset levelSelects the external trigger input source Triggering a transient pulseSlew Rate And Minimum Transition Time Risetime Transition LimitationInput Current, Voltage, and Power Measurement Transition Times and Slew Rates Short On/OffInput On/Off Saving and Recalling SettingsReading Remote Programming Errors Status Reporting Protection FeaturesResetting Latched Protection Overcurrent OverpowerOvervoltage Reverse Voltage Control ConnectorOvertemperature Remote SensingFault External Programming InputPage Installing The Modules InspectionPower Cord Configurations Procedure Installing The Mainframes Channel NumberRack Mounting Turn-On CheckoutCooling Line Voltage Switches Changing Line VoltageTurn-On/Selftest Gpib ErrorsChannel Errors Description Display DescriptionPower Test Controller ConnectionGpib Address Rear Panel Connectors and SwitchesWire Size Strip back AWGInput Binding Post Control Connector Sense SwitchIM and VM Pins Al and A2+Sand -S Com pin A3Application Connections Trigger ConnectorWiring Considerations Local Sense Connections Stranded Copper Wire Ampere Capacity Wire SizeAmpacity Remote Sense ConnectionsMaximum Wire Lengths to Limit Voltage Drops Zero-Volt Loading Connections12. Local Sensing 14. Parallel Operation Page Local Operation Local OperationControls and Indicators Description Chan Keys Function Keys Local Control Overview Using The Chan Keys Identifying the Selected Channel Using The Function KeysSelecting the Channel Turning the Input On/OffRecommended Programming Sequence Programming Ranges Setting the Mode of OperationSetting CC Values ExamplesSetting CR Values Examples Setting CV Values Programming RangeTransient Operation Shorting The Input Displaying Error Codes Using The System KeysSetting The Gpib Address Changing Wake-up Settings Recalling the Factory Default ValuesPage Output Enter/Output StatementsGpib Address EnterGetting Data Back Sending a Remote CommandSelecting a Channel Output 705 MeascurrRemote Programming Commands Output 705INPUT on Output 705MEASCURR? CC Mode ExampleCV Mode Example Output 705 Chan 2INPUT OFF Output 705MODEVOLTRemote Programming Flowchart Sheet Remote Programming Flowchart Sheet Continuous Transient Operation Example CR Mode ExampleOutput 705INPUT on Output 705MEASPOW? Output 705CHAN 2INPUT OFF Output 705MODECURROutput 705CHAN 1INPUT OFF Output 705MODEVOLT Pulsed Transient Operation ExampleSynchronous Toggled Transient Operation Example Output 705 Trigsour TIM Page Equipment Required CalibrationEquipment Required for Calibration Calibration CommandsCharacteristics Recommended ModelCalibration Flowcharts Example ProgramsCalibration Flowchart for a Modules Calibration Flowchart for a Modules Calibration Flowchart for a Modules Pause Subend Program Listing for a ModulesPause Print Voltage Calibration Line ElseEND if 610 Set low calibration point Calibration Flowchart for B Modules Calibration Flowchart for B Modules Calibration Flowchart for B Modules Program Listing for B Modules Clear Screen Print TABXY10,10CALIBRATION DoneWait 1260 If Flag then 1270 Output @LdRESReshipt 1280 Considerations For Operating In Constant Resistance Mode Considerations For Operating In Constant Resistance ModeConsiderations For Operating In Constant Resistance Mode Index IndexIndex Index 19, 20, 21 Agilent Sales and Support Offices Agilent Sales and Support OfficesManual Updates

6051A, 6050A specifications

Agilent Technologies has long been a leader in providing high-performance test and measurement solutions, and the 6050A and 6051A models exemplify this commitment to quality and innovation. The 6050A and 6051A are versatile signal generators that cater to a diverse range of applications, including research and development, manufacturing, and education, making them essential tools in laboratories and production environments.

The Agilent 6050A is a high-performance RF signal generator known for its frequency range capabilities, which span from 100 kHz to 20 GHz. It offers exceptional phase noise performance and low harmonic distortion, making it ideal for applications that require high signal integrity. The device supports various modulation formats, including AM, FM, and pulse modulation, allowing users to generate a wide range of test signals to simulate real-world conditions.

The 6051A builds upon the robust features of the 6050A with enhanced specifications and additional functionalities. It features a larger frequency modulation bandwidth, pushing the envelope for applications requiring more complex signal generation. The 6051A showcases a superior output power range, ensuring that test signals can be reliably produced at varying power levels. This model also includes advanced output control options that allow for precise signal manipulation, making it particularly suited for testing amplifiers and other RF components.

Both models share core technologies that ensure reliable performance, such as direct digital synthesis (DDS) and phase-locked loop (PLL) architectures. These technologies contribute to the exceptional frequency stability and accuracy that engineers and scientists have come to rely on. Additionally, the user-friendly interface integrated into both models simplifies operation and allows for quick configuration changes, facilitating efficient research and testing workflows.

With comprehensive connectivity options, including GPIB, USB, and Ethernet, the 6050A and 6051A can easily integrate into automated test environments. Their reliability, performance, and flexibility make them a perfect choice for those looking to advance their testing capabilities, whether in academic research, product development, or quality assurance in manufacturing.

In summary, the Agilent Technologies 6050A and 6051A signal generators are powerful tools designed to meet the demands of modern RF testing. Their advanced features, paired with Agilent’s reputation for quality and precision, make them invaluable assets in any engineering or research portfolio. Whether you require sophisticated signal generation for prototype testing or educational purposes, these models will deliver the performance needed to support your objectives.