Installation and Configuration
Verification
When you first power on the autoloader, it automatically runs a Power On Self Test (POST). During the POST, the right (amber) LED flashes rapidly. After the POST, the left (green) LED illuminates steadily, and after approximately three minutes the LCD displays the HP logo and drive type. Do one of the following:
■If the autoloader powers on successfully, continue configuring the autoloader. See “Configuration.”
■If the autoloader does not power on successfully, make sure that:
—The rear power switch is on.
—The power cord is inserted correctly.
—The SCSI bus is terminated.
—The SCSI cable is connected to the autoloader and host computer.
—The On/Off button on the front of the autoloader has been pressed.
—There is not an error code displayed on the autoloader’s LCD. (If an error message is displayed, see Chapter 6, “Troubleshooting.”)
If you cannot resolve the problem yourself, contact your authorized service representative.
Configuration
To configure your autoloader, use the Configuration submenu on the front panel. When you first power on the autoloader, it defaults to no password protection. After you set the security option, however, all the configuration functionality is
40 | SSL1016 Tape Autoloader Reference Guide |