air filter, removing 16 air filter, replacing 17 air filters 16 authorized reseller 73

B

before you contact HP 73 busway drop box, removing 18 busway drop box, replacing 19 busway drop boxes 18

C

chilled water flow actuator, removing

33

chilled water flow actuator, replacing

34

chilled water flow actuators

33

 

 

chilled water flow valve, removing

35

 

chilled water flow valve, replacing

36

chilled water flow valves

35

 

 

compliance 74

 

 

 

 

components

6

 

 

 

 

components, identification

6

 

 

components, mechanical

6

 

 

 

contact information 73

 

 

 

 

contacting HP

73

 

 

 

 

control cabinet identification

11

 

 

cooling system components

12

 

 

cooling system maintenance

62

 

 

customer self repair (CSR)

73

 

 

D

differential pressure sensor

20

 

differential pressure sensor, removing

21

differential pressure sensor, replacing

21

documentation

77

 

 

 

documentation feedback

77

 

door contact, removing

22

 

 

door contact, replacing

22

 

 

door contacts

22

 

 

 

downloading files 73

 

 

 

drain pan sensor, removing

23

 

drain pan sensor, replacing 24 drain pan sensors 23

drop box, removing 18 drop boxes 18

E

ECS components 64 ECS touchscreen 26

ECS touchscreen, removing 26 ECS touchscreen, replacing 26 electrical 65

electrical component identification 8 electrical specifications 70 environmental specifications 71 EPO button, removing 27

EPO button, replacing 28 EPO buttons 27, 29

EPO indicator, removing 30 EPO indicator, replacing 31 EPO thermister, removing 32 EPO thermister, replacing 32 EPO thermisters 31

F

fan banks

39

 

 

 

fan banks, removing

39

 

fan banks, replacing

40

 

fan filter, removing

16

 

fan filter, replacing

17

 

fan filters

16

 

 

 

fans

37

 

 

 

 

fans, removing

37

 

 

fans, replacing

38

 

 

Federal Communications Commission (FCC)

notice

74

 

 

 

filter

16

 

 

 

 

fire safety system

66

 

fire strobe light, removing

41

fire strobe light, replacing

42

fire strobe lights

41

 

 

fire suppression

66

 

 

Index 78

Image 78
Contents Abstract Page Contents Periodic maintenance Contacting HP Illustrated parts catalog Structural component identificationParts and part number identification Life safety component identification Electrical power component identification Component DescriptionExternal panel labels Front view shown Callout Electrical safety label Description Electrical safety label Description Control cabinet component identificationCooling system component identification HP POD 40c NA racksAisle clearances Cold aisle clearanceReplaceable components Hot aisle clearanceRemoval and replacement procedures Safety considerationsOperator safety Fire detection and suppression Air filterRemoving the air filter Replacing the air filter Busway drop box Removing the busway drop boxReplacing the busway drop box Differential pressure sensor Removing the differential pressure sensor Replacing the differential pressure sensorDoor position contact Removing the door position contactReplacing the door position contact Drain pan sensor Removing the drain pan sensorReplacing the drain pan sensor Removal and replacement procedures ECS touchscreen Removing the ECS touchscreenEPO button Replacing the ECS touchscreenRemoving the EPO button Replacing the EPO button EPO LED indicators Removing the EPO LED indicatorReplacing the EPO LED indicator EPO thermister Removing the EPO thermisterReplacing the EPO thermister External chilled water flow actuator Removing the external chilled water flow actuatorRemoval and replacement procedures External chilled water flow valve Replacing the external chilled water flow actuatorExternal pressure gauge isolation valve Removing the external chilled water flow valveReplacing the external chilled water flow valve Fan Removing the external pressure gauge isolation valveReplacing the external pressure gauge isolation valve Removing the fan Replacing the fan Fan bank Removing the fan bankReplacing the fan bank Fire strobe light Removing the fire strobe lightHumidifier Replacing the fire strobe lightRemoving the humidifier Removal and replacement procedures Replacing the humidifier Humidistat Removing the humidistatReplacing the humidistat Removal and replacement procedures Humidity sensor Removing the humidity sensorRemoval and replacement procedures Replacing the humidity sensor LED light Removing the LED lightTemperature sensor cold aisle Replacing the LED lightRemoving the cold aisle temperature sensor Replacing the cold aisle temperature sensor Temperature sensor hot aisle Removing the hot aisle temperature sensorRemoval and replacement procedures Replacing the hot aisle temperature sensor Vesda filter Removing the Vesda filterReplacing the Vesda filter Cooling system maintenance schedule Periodic maintenancePeriodic maintenance overview Qualified personnelLeak detection maintenance Humidifier if installed ECSElectrical POD Shut Down RequiredFire alarm and suppression system VesdaLife safety HP POD 40c NA structureAccess control Third-party componentsPeriodic maintenance Specifications General specificationsElectrical specifications Environmental specifications Water specificationsRack specifications Thermal and air flow performanceOptional features specifications Contacting HP Before you contact HPHP contact information Safety and regulatory compliance Warranty informationRegulatory information Glossary AHJPDU Documentation feedback Index Temperature sensor