HP TippingPoint Next Generation Firewall manual Setup, Shutdown, Snmp

Page 24

See Also

pwd (object)

set

Assigns values to one or more attribs or to a list of attribs contained within an object. The list may be a one or more attribute names, object names, or attrib/object pairs. To accept the current or default value, type the return key. To clear a String or IP Address value, enter a period (.), and then the return key.

The set command can use any read-write or write-only attribute. See SMS Attributes and Objects” on page 21 for more information.

Usage

set <attribobjectattrib=value> [...]

Related Commands

list, get

setup

Initial setup wizard for providing essential configuration settings for the SMS server. Non-essential values can be configured with other commands.

The setup command is automatically invoked with the first CLI login session. It is repeated with each new login session until the entire setup procedure is finally completed. To repeat the procedure, execute the setup command at any time. The setup procedure prompts you to enter the following information:

Network type (IPv4 default): IPv[4], IPv[6], or [B]oth <4,6,B>

Management IPv4 Address

Network Mask

IPv4 Default Gateway (optional)

Management IPv6 Address

IPv6 Default Route (optional)

DNS Server-1 (optional)

Usage

setup

shutdown

Shutdown and power-off the system. To restart the system, physically press the POWER button on the front of the unit. The --force option will reboot the system without prompting for confirmation. The cancel option aborts an in-progress shutdown operation.

Usage

shutdown [--force] [cancel]

snmp

The snmp command is used to manage the SNMP (Simple Network Management Protocol) values.

Usage

snmp

14 SMS Command Reference

Image 24
Contents HP TippingPoint Security Management System CLI Reference Unix is a registered trademark of The Open Group Table of Contents SMS Attributes and Objects List of Tables Page About This Guide Document Conventions Document Messages Customer Support Using the Command Line Interface Remote Paths Help Command Lists all commands, objects, and attributes Clear ClsConsole DateFactoryreset DirDns ExitFtp GetHelp Ifconfig IpconfigKbdcfg Mgmtsettings KeyList MonitorNicsettings PasswordNotify Ntp Ping Reboot Ping6Quit ResolveService-access RestartReverse RoutesSetup SetShutdown SnmpSnmp-request Snmp-trapSnmpget SnmpwalkSsh TimeTouch TracerouteUpdate UsersVersion ‘read-only’View WebWho SMS Attributes and Objects CliCtl To set ctl.upgrade-source , this takes Time that the database was String Read-only Re-initialized High availability Health Indication for Celsius Kbd DesignationLicense Logs NetFor information on set net, see set on Related Commands 11 net Attributes Description Type Access Range Pkg 13 pkg Attributes Description Type Access Range Pwd Radius RadiusRoute PAP, CHAP, MSCHAP, MSCHAP2 EAPMD5Route6 SmtpSHA DES Attrib used to remove an Snmp trap String Write-only TripleDES Examples Snmp.trap-user Svc To true. To disable, set to false Example Sys 24 time Attributes Description Type Access Range SMS Attributes and Objects
Related manuals
Manual 252 pages 61.66 Kb Manual 68 pages 46.8 Kb Manual 54 pages 53.98 Kb