Shutdown
1.Discharge the system voltage (page 20).
2.Flush the spray gun. See page 26.
ti1276a
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the Pressure Relief Procedure on whenever you are instructed to relieve the pressure.
3. Relieve the pressure (page 20).
ti1276a
4.Hang the gun from its hook or place it in the acces- sory holster, with the nozzle pointing down. Be sure to keep the gun from grounding out.
ti1288a
Operation
Low Voltage Adjustment (Smart Guns Only)
The ES HI/LO switch enables you to switch between full voltage and a lower voltage output. The lower voltage is factory set, but can be adjusted.
1.Set the ES HI/LO switch to LO.
2.Remove the LO VOLTAGE adjustment plug (53). Set the desired voltage, using a small screwdriver to slide switches 1 and 2 ON or OFF, according to Table 4 . Also see FIG. 15..
OFF
ON 2 1
0 KV 100%
μα
53
ti1529a
Fig. 15. Low Voltage Adjustment Switches
Table 4: Low Voltage Adjustment
| 1 | 2 | kV |
|
|
|
|
| ON | ON | 50 |
|
|
|
|
Factory Setting > | ON | OFF | 40 |
|
|
|
|
| OFF | ON | 35 |
|
|
|
|
| OFF | OFF | 30 |
|
|
|
|
309293J | 25 |