HP GRACO OR PRO TI1681A manual Test Electrode Resistance

Page 32

Electrical Tests

Test Electrode Resistance

1.Prepare the gun for service as instructed on page 41.

2.Insert a conductive rod (B) into the gun barrel (removed for the power supply test) and against the metal contact (C) in the front of the barrel.

3.Measure the resistance between the conductive rod

(B) and the electrode (29). The resistance should be 20-30 megohms. See FIG. 19..

4.If in range, refer to Electrical Troubleshooting on page 39 for other possible causes of poor perfor- mance, or contact your Graco distributor.

5.Remove the electrode (29), page 43. Measure the resistance between the contact (E) and the elec- trode wire (F). The resistance should be 20-30 megohms. If out of range, replace the electrode. See FIG. 20..

6.Make sure the metal contact (C) in the barrel, the nozzle contact ring (7a, FIG. 21.), and the electrode contact (E) are clean and undamaged.

C

29

B

ti1499a

F 29 E

ti1548a

Fig. 20. Electrode

7a

ti1513a

Fig. 21. Nozzle Conductive O-Ring

Fig. 19. Test Electrode Resistance

32

309293J

Image 32
Contents Instructions/Parts List Table of Contents List of Models FM ApprovedEN 50059 Compliant Gun Model DescriptionSymbols Electric Shock HazardFire and Explosion Hazard Toxic Fluid HazardEquipment Misuse Hazard Pressurized Equipment HazardSpraying Waterborne Fluids Electrostatically IntroductionHow the Electrostatic Air Spray Gun Works Gun Overview Gun OverviewInstallation Install the SystemSystem Requirements Fire, Explosion, and Electric Shock HazardTypical Installation PRO Xs Waterborne System Key Ventilate the Spray Booth Connect the Air LineGround the Cabinet Connect the Waterborne Fluid HoseShielded Hose Unshielded HoseWaterborne Hose Dimensions At Graco WB100 Enclosure Unshielded fluid connectionAgitator Kit Agitator KitFluid Regulator Kit Fluid Regulator KitAir Caps Select a Fluid Nozzle and Air CapFluid Nozzles Grounding Check Electrical Grounding Check Gun GroundingOperating Checklist OperationTurn off the main air supply valve B Fire and Explosion Hazard Adjust the Spray PatternFill the Fluid Supply Fully open the fluid adjustment valve Air Regulator Settings Air Hose Length Air Regulator Setting Ft m Psi MPa, barWhen you finish spraying, perform the Shutdown procedure on Shutdown Low Voltage Adjustment Smart Guns OnlyLow Voltage Adjustment Maintenance Flush the Spray GunDaily Care and Cleaning Do not immerse the gun in fluidMaintenance Clean the Air Cap and Fluid Nozzle ProcedureGrease Door Latch Threads Equipment NeededElectrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance ElectrodeTest Ground Strip Resistance Test Cylinder ResistanceTroubleshooting Voltage Loss TroubleshootingSpray Gun Waterborne Fluid HoseVisual Check TestsTroubleshooting Spray Pattern Troubleshooting Gun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingLowing the Fluid Voltage Discharge Grounding Procedure See Check Electrical Grounding on 18 and Test Gun ResistancePrepare the Gun for Service RepairAir Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts TI1481a Description Qty Description Qty 51 Ref 19a TI1488A Description Qty SWITCH, ES HI/LO 271 253 276 228 262 NUT Bulkhead Connector 1/4 Tubing and Wiring Chart Code Length Description In. mmDetail of Control Box Tubing and Wiring DiagramsDetail of Door Interlock Switch Fluid Line Accessories AccessoriesAir Line Accessories Gun Accessories Miscellaneous AccessoriesPart No Agitator Accessory Kit items 402 407 401 406 403 408 404 406 RefPart No Fluid Regulator Accessory Kit items 506 507 502 505 503Data Technical DataCategory Toll Free Graco Standard WarrantyGraco Information