Toshiba RAV-SM2802DT-E, RAV-SM2242DT-TR, RAV-SM2802DT-TR Troubleshooting, Specifications

Page 81

– 81 –

Concealed Duct High Static Pressure

Owner’s Manual

12 TROUBLESHOOTING

CAUTION

If any of the following conditions occur, turn off the main power supply switch and immediately contact the dealer :

Switch operation does not work properly.

The main power fuse often blows out, or the circuit breaker is often activated.

A foreign matter or water fall inside the air conditioner.

When the air conditioner does not operate even after the cause of the protective device activation has been removed.

(The operation lamp and on the remote controller are flashing.)

• Any other unusual conditions are observed.

Before you ask for servicing or repairs, check the following points.

KRecheck

Inoperative

The main power switch is turned off.

The circuit breaker is activated to cut off power supply.

The main power fuse has blown out.

Does not cool well or heat well

The air inlet and/or outlet of the outdoor unit is blocked.

Doors or windows are opened.

The set temperature is too high (In cooling) or low (In heating).

KThese are not failures.

Indoor unit or outdoor unit makes a strange noise.

When the temperature suddenly changes, the indoor or outdoor unit occasionally makes a strange noise because of expansion/ contraction of parts or change of refrigerant flow.

Air leaking noise is heard occasionally.

It is generated by the solenoid valve when it is actuated.

A clattering sound is heard when the power is turned on.

It is generated by the outdoor unit during preparation for operation.

The room air is smelly or a bad odor comes from the air conditioner.

• Smells impregnated in the walls‚ carpets, furniture, clothing, or furs, come out.

Outdoor unit is frosted in heating operation.

Water drains from outdoor unit.

he outdoor unit is sometimes frosted in heating operation.

In that case, the unit automatically performs defrosting (for 2 to 10 minutes) for increasing the heating efficiency.

In defrosting operation, both the indoor and outdoor units stop air flow.

Hiss sound is heard when flow of the refrigerant is changed for defrosting.

Resultant water of automatic defrosting in heating operation drains from outdoor unit.

A white mist of chilled air or water is generated from the outdoor unit.

• When the indoor unit in cooling operation or the outdoor unit in defrosting operation occasionally steams.

Check these items. If any of these problems still remains, stop the operation, turn off the leakage breaker, and then notifies the dealer of the serial number and details of the error. Never repair any part by yourself as it is dangerous.

When

and a combination of , , , or

and a number are displayed on the remote controller, also inform

the dealer of the display content.

 

Concealed Duct High Static Pressure

 

 

Owner’s Manual

13 SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

Model

 

Sound power level (dB)

Weight (Kg)

 

 

 

 

 

 

 

 

 

Cooling

Heating

 

 

 

 

 

 

 

 

 

 

RAV-SM2242DT-E

 

74

74

160

 

 

 

 

 

 

 

 

 

RAV-SM2802DT-E

 

75

75

160

 

 

 

 

 

 

 

 

 

Declaration of Conformity

Manufacturer:

Toshiba Carrier Corporation

 

336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN

Authorized

Nick Ball

Representative/TCF holder: Toshiba EMEA Engineering Director

Toshiba Carrier UK Ltd.

Porsham Close, Belliver Industrial Estate,

PLYMOUTH, Devon, PL6 7DB.

United Kingdom

Hereby declares that the machinery described below:

Generic Denomination: Air Conditioner

Model/type:RAV-SM2242DT-E,

RAV-SM2802DT-E,

RAV-SM2242DT-TR,

RAV-SM2802DT-TR

Commercial name:

Digital Inverter Series Air Conditioner

Complies with the provisions of the “Machinery” Directive (Directive 2006/42/EC) and the regulations transposing into national law

Complies with the provisions of the following harmonized standard:

EN 378-2: 2008

NOTE

This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s consent.

Information according to EMC Directive 2004/108/EC

(Name of the manufacture)

TOSHIBA CARRIER CORPORATION

 

 

(Address, city, country)

336 Tadehara, Fuji-shi, Shizuoka-ken

 

416-8521 Japan

 

 

(Name of the Importer/Distributor)

TOSHIBA CARRIER UK Ltd.

 

 

(Address, city, country)

Porsham Close, Belliver Industrial Estate, PLYMOUTH,

 

Devon, PL6 7DB. United Kingdom

 

 

– 21 –

– 22 –

Image 81
Contents Split Type Contents Original instruction Explanation of illustrated marks Explanation of indicationsWork undertaken Protective gear worn Indication ExplanationDescription Confirmation of warning label on the main unitPrecaution for Safety Proceeding with the repair work Refrigerant used by this air conditioner is the R410A Resistance and water drainage Model Sound power level dB Weight kg Cooling Heating SpecificationsExplanations given to user RelocationPipe Materials Safety Caution Concerned to New RefrigerantCopper pipe Piping Flare nutGeneral tools Conventional tools can be used ToolsR410A Conventional air Used tool UsageModel Indoor unit Concealed Duct High static pressure TypeRAV-SM2242DT-TR RAV-SM2802DT-TR Concealed Duct High static pressure Type ContinedSM2242DT-E Indoor UnitIndoor unit Dimension tableUnit Indoor100 RAV-SM2242 type350 300 250 200 150 100 3200 3360 RAV-SM2802 typeLow static pressure F1 Wire connection change of fan motorStandard Middle static pressure F2 High static pressure F3Parts name Type Specifications Specifications of Electrical PartsConnection of Wired Simple Remote Controller Indoor Controller Block DiagramIndoor unit #1 Header Outdoor unitOutline of specifications Remarks Control outlineOutside temp Correction value a Indoor formation Setup dataTa ˚C Cooling +1.5 Tc, Tcj TcnConditions Tc n Control temp. C Setup at shipmentHeat Case of wired remote controllerUsual control MCC-1403 Print Circuit BoardFunction Connector Pin Specifications Remarks Optional Connector Specifications of Indoor P.C. BoardBefore troubleshooting Troubleshooting procedureWired remote controller type Confirmation of error log Main remote controller RBC-AMT32EHow to read check monitor display ProcedureRemote controller switch monitoring function Check Code List Indoor Indoor unit detected Remote controller detectedCentral control devices detected Error mode detected by indoor unit Operation of diagnostic function Judgment and measuresCause of operation Status Error mode detected by outdoor unit AfterSeries H03 Current detection circuit error Stop Power supply error of remote controller, Indoor YES E09 errorE10 error E04 errorE18 error E08, L03, L07, L08 errorL09 error L20 error L30 errorP30 error Central controller P01 error P10 errorP19 error F01 error F02 errorC06 error 11 model connection interface E03 error Master indoor unit F29 errorP31 error Follower indoor unit Temperature sensor TA, TC, TCJ Temperature Resistance value characteristic tableTA, TC, TCJ sensors Representative valueResistance value Part name Checking procedureReplacement procedures Replacement of Service P.C. BoardSetting data read out from Eeprom C. Board for indoor unit servicing replacement proceduresCode No. required at least Contents Writing the setting data to Eeprom StepOperation is available again Indoor unit capacity Code No Type Code NoPractical operation Test Run Setup on Remote Controller Wired remote controllerLED Display on Indoor P.C. Board D002 Red Function Selection SetupD203 Red TEMP. buttons, specify the Code No. DNFunction selection item No. DN list ContentsSetup method Wired remote controllerHow to set wired remote controller as sub remote controller When connected 2 remote controllers operate an indoor unitContents Group control operation Calling of error historyPushing Test button returns the display to usual display System examplePower on Indoor unit power-ON sequenceModel connection interface wiring connection Microprocessor block diagramModel Connection Interface Function Model name TCB-PCNT30TLE2C. board switch SW01 setup Wiring specificationsAddress setup External view of P.C. board assemblyPush Test + Vent buttons for 4 seconds or more Push Test buttonDuring unset time, At shipment from factory is displayed Code No Data at shipment Setup data range Address Setup & Group Control Terminology System ConfigurationOnly turning on source power supply Automatic completion Automatic Address Example from Unset Address No miswiringUsing timer time Buttons, set the line address Using the temperature setup ButtonsPush SET Button. OK when display goes on Push Test PushProcedure Confirmation of indoor unit No. positionTo know the position of indoor unit body by address Contents Precautions for Safety Examples of indication on the carton Symbol DescriptionConcealed Duct High Static Pressure Relocation Other cautions DescriptionWired Remote Controller Part NamesDisplay section Operation section Preparation Correct UsageStart StopPower Saving Mode Timer OperationPush button during operation SetAdvanced Settings Power saving modeEnergy Saving Recommendations Cleaning air filters MaintenanceMaintenance List Preparing for long Shut Down PeriodDo not install the air conditioner in the following places InstallationAIR Conditioner Operations and Performance Be careful with noise or vibrationsSpecifications TroubleshootingInstallation Manual Work undertaken Protective gear worn Definition of Protective GearElectrical wiring Selection of installation locationGeneral Refrigerant pipingAccessory Parts New Refrigerant Air Conditioner InstallationTo Disconnect the Appliance from Main Power Supply Installation under high-humidity atmosphere Selection of Installation PlaceInstallation space Unit mm Filter cleaning sign term settingInstallation of hanging bolt External DimensionsInstallation of indoor unit Installation of hanging boltDuct installation example First floor Diagrams for making connecting flangesDuct design Air outlet port flangeFAN Characteristics RAV-SM2242 TypeRAV-SM2802 Type Drain Piping Work Wire connection change of fan motorLow static pressure F1 Standard Middle static pressure F2Pipe material, size and insulator Connecting drain pipeDrain up Check the drainingHeat insulating process Refrigerant Piping and EvacuatingRefrigerant Piping Liquid side refrigerant pipe connectionEvacuation Gas side refrigerant pipe connectionWiring diagram Wire connectionPower and Wiring Specification Electrical ConnectionChanging of setting applicable control Remote Controller WiringWiring diagram Applicable ControlsFilter sign setting Remote controller switch monitoring functionConcealed Duct High Static Pressure Procedure To secure better effect of heatingManual address setup procedure Procedure exampleInstallation Manual Procedure Group control8C Operation ProcedureTest RUN Daily maintenanceBefore test run Execute a test runConfirmation of error log Concealed Duct High Static PressureInstallation ManualConfirmation and check Status Error codes and parts to be checkedHow to replace the parts Fan assembly and replacement Part name Work procedure RemarksFan assembly Fan/Fan case Pull out the fan assembly a fan toward you104 Fan motor 2242DT-E Location Description215, 216 219 218 214218 213 108 Check of Concentration Limit Toshiba Carrier Corporation
Related manuals
Manual 41 pages 43.38 Kb

RAV-SM2802DT-TR, RAV-SM2242DT-TR, RAV-SM2802DT-E specifications

Toshiba has long been a leader in heating, ventilation, and air conditioning (HVAC) technology, offering innovative solutions that cater to both residential and commercial needs. Among their impressive lineup, the Toshiba RAV-SM2802DT-E and RAV-SM2242DT-E stand out as exceptional models designed for efficiency, performance, and comfort.

The RAV-SM2802DT-E is a powerful unit ideal for larger spaces, boasting a cooling capacity of 28,000 BTU/h and a heating capacity of 31,000 BTU/h. This model features a highly efficient inverter compressor, which adjusts the power consumption based on the cooling or heating demand, ensuring optimal energy use. This inverter technology not only reduces energy consumption but also maintains a stable indoor temperature for enhanced comfort.

On the other hand, the RAV-SM2242DT-E is tailored for mid-sized applications with a cooling capacity of 22,000 BTU/h and a heating capacity of 25,000 BTU/h. This model also embraces inverter technology, promoting lower operational costs while delivering reliable performance. Both units come with a high energy efficiency rating, reducing environmental impact and saving on utility bills.

One of the key characteristics of these Toshiba models is their advanced filtration system. Equipped with a high-performance filtration mechanism, they can effectively reduce dust, allergens, and other pollutants, ensuring a healthier indoor environment. The units also operate quietly, contributing to a peaceful atmosphere, whether in a home, office, or commercial space.

Both the RAV-SM2802DT-E and RAV-SM2242DT-E are designed with user convenience in mind. They come with a user-friendly remote control, allowing for easy adjustments and settings from anywhere in the room. Compatibility with smart home systems further enhances user experience by enabling remote monitoring and control through smartphones or tablets.

Constructed with durability in mind, these units are built to withstand diverse weather conditions, making them suitable for various climatic environments. Additionally, their aesthetic design allows for seamless integration into any setting, ensuring that performance does not compromise on looks.

In summary, Toshiba's RAV-SM2802DT-E and RAV-SM2242DT-E offer a blend of superior technology, energy efficiency, and user-friendly features. With their inverter technology, advanced filtration systems, and durable designs, these models represent Toshiba's commitment to quality and innovation in the HVAC industry. Whether for residential or commercial applications, these units guarantee comfort and reliability all year round.