2.Summary of system equipment
Technical specifications - outdoor units
Rating | hp | 5 | 6 | 8 | 10 | 12 |
|
Cooling only model |
| 0501T8 | 0601T8 | 0801T8 | 1001T8 | 1201T8 |
|
Heat pump model |
| 0501HT8 | 0601HT8 | 0801HT8 | 1001HT8 | 1201HT8 | |
Cooling capacity | kW | 14.0 | 16.0 | 22.4 | 28.0 | 33.5 |
|
Heating capacity | kW | 16.0 | 18.0 | 25.0 | 31.5 | 37.5 |
|
Technical specifications - combination of outdoor units
Rating | hp | 5 | 6 | 8 | 10 | 12 | 14 | 16 |
Cooling only model |
| 0501T8 | 0601T8 | 0801T8 | 1001T8 | 1201T8 | 1401T8 | 1601T8 |
Heat pump model |
| 0501HT8 | 0601HT8 | 0801HT8 | 1001HT8 | 1201HT8 | 1401HT8 | 1601HT8 |
Cooling capacity | kW | 14.0 | 16.0 | 22.4 | 28.0 | 33.5 | 38.4 | 45.0 |
Heating capacity | kW | 16.0 | 18.0 | 25.0 | 31.5 | 37.5 | 43.0 | 50.0 |
Combined outdoor units | hp | 5 | 6 | 8 | 10 | 12 | 8 | 8 |
|
| - | - | - | - | - | 6 | 8 |
No. of connectable indoor units |
| 8 | 10 | 13 | 16 | 20 | 23 | 27 |
Rating | hp | 18 | 20 | 22 | 22 | 24 | 24 | 26 |
Cooling only model |
| 1801T8 | 2001T8 | 2201T8 | 2211T8 | 2401T8 | 2411T8 | 2601T8 |
Heat pump model |
| 1801HT8 | 2001HT8 | 2201HT8 | 2211HT8 | 2401HT8 | 2411HT8 | 2601HT8 |
Cooling capacity | kW | 50.4 | 56.0 | 61.5 | 61.5 | 68.0 | 68.0 | 73.0 |
Heating capacity | kW | 56.5 | 63.0 | 69.0 | 69.0 | 76.5 | 76.5 | 81.5 |
Combined outdoor units | hp | 10 | 10 | 8 | 12 | 8 | 12 | 10 |
|
| 8 | 10 | 8 | 10 | 8 | 12 | 8 |
|
| - | - | 6 | - | 8 | - | 8 |
No. of connectable indoor units |
| 30 | 33 | 37 | 37 | 40 | 40 | 43 |
Rating | hp | 28 | 30 | 32 | 32 | 34 | 34 | 36 |
Cooling only model |
| 2801T8 | 3001T8 | 3201T8 | 3211T8 | 3401T8 | 3411T8 | 3601T8 |
Heat pump model |
| 2801HT8 | 3001HT8 | 3201HT8 | 3211HT8 | 3401HT8 | 3411HT8 | 3601HT8 |
Cooling capacity | kW | 78.5 | 84.0 | 90.0 | 90.0 | 96.0 | 96.0 | 101.0 |
Heating capacity | kW | 88.0 | 95.0 | 100.0 | 100.0 | 108.0 | 108.0 | 113.0 |
Combined outdoor units | hp | 10 | 10 | 8 | 12 | 10 | 12 | 10 |
|
| 10 | 10 | 8 | 10 | 8 | 12 | 10 |
|
| 8 | 10 | 8 | 10 | 8 | 10 | 8 |
|
| - | - | 8 | - | 8 | - | 8 |
No. of connectable indoor units |
| 47 | 48 | 48 | 48 | 48 | 48 | 48 |
Rating | hp | 36 | 38 | 40 | 42 | 44 | 46 | 48 |
Cooling only model |
| 3611T8 | 3801T8 | 4001T8 | 4201T8 | 4401T8 | 4601T8 | 4801T8 |
Heat pump model |
| 3611HT8 | 3801HT8 | 4001HT8 | 4201HT8 | 4401HT8 | 4601HT8 | 4801HT8 |
Cooling capacity | kW | 101.0 | 106.5 | 112.0 | 118.0 | 123.5 | 130.0 | 135.0 |
Heating capacity | kW | 113.0 | 119.5 | 126.5 | 132.0 | 138.0 | 145.0 | 150.0 |
Combined outdoor units | hp | 12 | 10 | 10 | 12 | 12 | 12 | 12 |
|
| 12 | 10 | 10 | 10 | 12 | 12 | 12 |
|
| 12 | 10 | 10 | 10 | 10 | 12 | 12 |
|
| - | 8 | 10 | 10 | 10 | 10 | 12 |
No. of connectable indoor units |
| 48 | 48 | 48 | 48 | 48 | 48 | 48 |
Branching joints and headers
| Model |
| Usage |
|
|
|
| Appearance | ||
| Indoor unit capacity code (*1) : Total below 6.4 |
|
|
|
|
|
| |||
|
| Indoor unit capacity code (*1) : Total 6.4 or more and below 14.2 | (*2) |
|
|
|
| |||
|
|
|
|
| ||||||
|
| Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 | (*2) |
|
|
|
| |||
|
| Indoor unit capacity code (*1) : Total 25.2 or more | (*2) |
|
|
|
| |||
| Indoor unit capacity code (*1) : Total below 14.2 |
| Max.4 |
| ||||||
|
| Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 |
| branches |
| |||||
| Indoor unit capacity code (*1) : Total below 14.2 |
| Max.8 |
|
|
| ||||
|
| Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 |
| branches |
| |||||
|
| 1 set of 3 types of |
|
|
|
|
|
| ||
(For connection of |
|
| The required quantity is arranged and they are combined at the site. | |||||||
outdoor units) |
|
|
|
|
|
|
|
|
|
|
|
|
| Connection piping | Corresponding dia. (mm) | Q’ty |
|
|
|
| |
|
|
| Balance pipe | Ø3/8” | 1 |
|
|
|
| |
|
|
| Liquid side piping | Ø3/8” to Ø7/8” | 1 |
|
|
|
| |
|
|
| Gas side piping | Ø5/8” to | 1 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
*1 The capacity code can be obtained from page 10 (capacity code is not actual capacity).
*2 If total capacity code value of indoor unit exceeds that of outdoor unit, apply capacity code of outdoor unit.
*3 When using
*4 Max. 6.0 capacity code in total can be connected.
*5 If capacity code of outdoor unit is 26 and more, it is not used for 1st branching.
*6 Model names for outdoor and indoor units described in this guide are shortened because of the space constraints.
7