Toshiba HFC R-410A manual 130.0 135.0

Page 68

Outdoor units (combination)

Rating

hp

46

 

 

 

 

48

 

 

 

Cooling only system MMY

 

AP4601T8

 

 

 

 

AP4801T8

 

 

 

Heat pump system MMY

 

AP4601HT8

 

 

 

 

AP4801HT8

 

 

 

Outdoor unit type

 

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

Outdoor unit combination

 

 

 

 

 

 

 

 

 

 

cooling only MMY-MAP

 

1201T8

1201T8

1201T8

1001T8

1201T8

1201T8

1201T8

1201T8

Outdoor unit combination

 

 

 

 

 

 

 

 

 

 

heat pump MMY-MAP

 

1201HT8

1201HT8

1201HT8

1001HT8

1201HT8

1201HT8

1201HT8

1201HT8

Cooling capacity

kW

130.0

 

 

 

 

135.0

 

 

 

Heating capacity

kW

145.0

 

 

 

 

150.0

 

 

 

Power supply ± 10%

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

 

400-3-50

400-3-50

400-3-50

400-3-50

Voltage range

V

380-415

380-415

380-415

380-415

 

380-415

380-415

380-415

380-415

Power input, cooling

kW

45.59

 

 

 

 

49.67

 

 

 

Power factor, cooling

%

95

 

 

 

 

95

 

 

 

Operating current, cooling

A

69.27

 

 

 

 

75.47

 

 

 

EER, cooling

kW/kW

2.85

 

 

 

 

2.72

 

 

 

Starting current

A

1.0

 

 

 

 

1.0

 

 

 

Power input, heating

kW

39.85

 

 

 

 

41.80

 

 

 

Power factor, heating

%

95

 

 

 

 

94

 

 

 

Operating current, heating

A

60.55

 

 

 

 

64.19

 

 

 

COP, heating

kW/kW

3.64

 

 

 

 

3.59

 

 

 

Starting current

A

1.0

 

 

 

 

1.0

 

 

 

Unit appearance

 

Silky shade (Munsell 1Y8.5/0.5)

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

Height

mm

1800

1800

1800

1800

 

1800

1800

1800

1800

Width

mm

990

990

990

990

 

990

990

990

990

Depth

mm

750

750

750

750

 

750

750

750

750

Total weight - cooling only unit

kg

256

256

256

256

 

256

256

256

256

Total weight - heat pump unit

kg

258

258

258

258

 

258

258

258

258

Heat exchanger

 

Finned type

 

 

 

 

 

 

 

 

Sound power level

dB(A)

78.0

 

 

 

 

78.0

 

 

 

Sound pressure level

dB(A) at 1 m 65.0

 

 

 

 

65.0

 

 

 

Fan type

 

Propeller

Propeller

Propeller

Propeller

Propeller

Propeller

Propeller

Propeller

Motor power input

kW

0.6

0.6

0.6

0.6

 

0.6

0.6

0.6

0.6

Air flow

l/s

2917

2917

2917

2917

 

2917

2917

2917

2917

 

m3/h

10500

10500

10500

10500

 

10500

10500

10500

10500

Compressor type

 

Hermetic

Hermetic

Hermetic

Hermetic

Hermetic

Hermetic

Hermetic

Hermetic

Motor power input

kW

4.2 x 2

4.2 x 2

4.2 x 2

3.1 x 2

4.2 x 2

4.2 x 2

4.2 x 2

4.2 x 2

Refrigerant charge R-410A*

 

 

 

 

 

 

 

 

 

 

Cooling

kg

11.0

11.0

11.0

11.0

 

11.0

11.0

11.0

11.0

Heating

kg

12.5

12.5

12.5

12.5

 

12.5

12.5

12.5

12.5

Pipework**

 

 

 

 

 

 

 

 

 

 

Suction line type - diameter

 

Brazed - 1-1/8

Brazed - 1-1/8

Brazed - 1-1/8

Brazed - 7/8

Brazed - 1-1/8

Brazed - 1-1/8

Brazed - 1-1/8 Brazed - 1-1/8

Liquid line type - diameter

in

Flare - 1/2

Flare - 1/2

Flare - 1/2

Flare - 1/2

Flare - 1/2

Flare - 1/2

Flare - 1/2

Flare - 1/2

Balance pipe type - diameter

in

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Maximum equivalent length separation

m

175

175

175

175

 

175

175

175

175

Maximum actual piping length

m

150 (if equivalent bend length is longer, equivalent length is standard)

 

 

Maximum total piping length

m

300

300

300

300

 

300

300

300

300

 

Maximum lift - indoor unit above/below*** m

40/50

40/50

40/50

40/50

 

40/50

40/50

40/50

40/50

Control wiring

 

Shielded wire 1.25 mm2 x 2 cores up to 2000 m

 

 

 

 

Central remote controller

 

Shielded wire 1.25 mm2 x 2 pieces up to 1000 m, 2.0 mm2 x 2 pieces up to 2000 m

 

 

Max. number of connectable indoor units

48

 

 

 

 

48

 

 

 

High-pressure switch

MPa

Off: 2.90/On: 3.73

 

 

 

 

 

 

 

Protection devices

 

Discharge temperature sensor, suction temperature sensor, compressor crankcase heater,

 

 

 

high-pressure switch, overcurrent sensor, high-pressure sensor, low-pressure sensor,

 

 

 

overcurrent relay

 

 

 

 

 

 

 

Operating range, cooling†

°C

-5 to 43 db

-5 to 43 db

-5 to 43 db

5 to 43 db

 

-5 to 43 db

-5 to 43 db

5 to 43 db

-5 to 43 db

Operating range, heating†

°C

-20 to 16 wb

-20 to 16 wb -20 to 16 wb

-20 to 16 wb

 

-20 to 16 wb

-20 to 16 wb

-20 to 16 wb

-20 to 16 wb

Rated conditions: Cooling: Indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db

Heating: Indoor air temperature 20°C db, outdoor air temperature 7°C db/6°C wb

The standard piping equals 5 m main pipe length plus 2.5 m branch pipe length.

*The amount does not cover extra piping lengths. Refrigerant must be added on-site in accordance with the actual piping length.

** The maximum total piping length is the sum of one-way piping lengths on the liquid side or gas side.

*** If the indoor unit is above, maximum lift is reduced to 30 m, if the height difference between indoor units exceeds 3 m.

† Please refer to page 24.

68

Image 68
Contents Super Modular Multi Page Super Modular Multi System Contents Outline of Toshiba Super Modular Multi System S-MMS Outdoor unit Indoor unit  Self-diagnostic system  Compact Largest system capacity  Energy saving designSummary of system equipment Technical specifications outdoor unitsTechnical specifications combination of outdoor units Branching joints and headersOutdoor unit model line-up cooling only units Product designationCombined capacity range Rated conditionsOutdoor unit model line-up heat pump units MMY- M AP 000 0 H TTechnical specifications indoor units Remote controller Simplified remote controller Connected to indoor unitWireless remote controller kit Connected to indoor unit TCB-AX21U W-EMaster Weekly timer RBC-EXW21E Connected to central remoteController, wired remote controller 8HP Basic system configurationSystem legend example 8 hp system Hp system 10HP10HP 10HP Hp system 10HP 10HP 10HP Outdoor unit Indoor unit Remote controller Equipment selection procedure Selection flow chartIndoor unit and outdoor unit combination Capacity codeCapacity correction value Indoor air wet bulb temperature C  Correction of outdoor unit diversity Capacity correction value Indoor air dry bulb temperature C  Correction of outdoor unit diversity Operating temperature range Heating modeCapacity calculation for each indoor unit Rated conditionsOutside view Example of equipment selectionSelection criteria for each floor Procedure and result of equipment selection Air conditioning load Equipment selection Floor Room NoIndoor unit Outdoor unit Model Capacity kW Cooling Heating Cooling HeatingExample Equipment selection based on system load profile Load in each roomSchematic diagram MMY-AP2801T8 MMY-AP2801HT8Refrigerant piping design Check of concentration limitFree branching system Line branching system Header branching systemAllowable value Piping section Allowable length/height difference of refrigerant pipingSystem restrictions Gas side Liquid side Selection of refrigerant piping Pipe size of outdoor unit Table Model name Charging requirement with additional refrigerant Calculating the amount of additional refrigerant requiredCharge Cooling only Liquid side pipe diameterWiring design Outdoor unit power supplyElectrical wiring design GeneralControl wiring design Control wiring diagram Control wiring between outdoor units L5 WiringType LengthDesign FLA MCA MocpCompressor Fan motor Power supply Single outdoor unit Heat pump Cooling only NominalVoltage Range Ph-Hz Min Max Combination of outdoor units Heat pump Cooling only NominalControl via indoor remote controller Control via the central remote controllerControls Range of controls to meet various system needsApplications for indoor remote controller Basic function System diagram Model Individual controlTwo remote controllers Control by weekly timerApplication controls for central remote controller Basic function System diagram ModelIndoor remote controller Function of central remote controllerAvailable TCB-PCNT30TLEApplication control for network TCB-1FLNBACnet BMS-LSVBMS-TP5120ACE Accessories Indoor unit accessoriesRemote controller Indoor unit type Accessory name Model Applicable modelTechnical specifications Indoor units Way ceiling cassettesRBC-UW136PG RBC-UW266PG Room thermostat RBC-UY135PG RBC-US165PG RBC-US265PGFan motor power input Static pressure factory setting Static pressure maxIndoor units Standard ducted units Sound pressure level high/medium/low** dBAUnit weight Static pressure factory settingSound power level high Indoor units High-pressure ducted unitsIndoor units Slim duct units Lower air inlet Sound power level high/medium/lowRear air inlet Sound power level high/medium/low Indoor units Ceiling-suspended units Indoor units High-wall units 1 Series Indoor units High-wall units 2 Series Indoor units Floor-mounted console units Indoor units Concealed chassis units Static pressureIndoor units Floor-mounted cabinet units Outdoor units Outdoor units combination DBA 74.5 DBA 75.0 24.26 Power factor, cooling Operating current, cooling 30.51 258 256 DBA 76.5 77.0 Max. number of connectable indoor units High-pressure switch Power supply ± 10% Ph-Hz 400-3-50 130.0 135.0 Fan characteristics Case of square duct flange of discharge sectionMMD-AP0071BH, AP0091BH MMD-AP0121BHMMD-AP0241BH, AP0271BH MMD-AP0361BHMMD-AP0301BH MMD-AP0481BH, AP0561BHHigh-pressure ducted unit MMD-AP0181HMMD-AP0241H, AP0271H MMD-AP0361HMMD-AP0721H MMD-AP0961HMMD-AP0151SPH MMD-AP0181SPH Slim duct unitMMD-AP0071SPH, AP0091SPH MMD-AP0121SPH Slim duct unit with filter attached MMD-AP0151SPHDimensional drawings All dimensions are given in mmIndoor unit 4-way ceiling cassette MMU-AP0091H to P0561HMMU-AP0071WH, AP0091WH, AP0121WH All dimensions are given in mm ViewIndoor unit 2-way ceiling cassette Model MMU-AP0151WH to AP0181WH MMU-AP0241WH to AP0301WH View Space required for installation and servicingMMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH, AP0301WH MMU-AP0481WH Indoor unit 1-way ceiling cassette MMU-AP0071YH, AP0091YH, AP0121YHAP0241SH MMU-AP0151SH, AP0181SH, AP0241SHView Model MMU AP0151SH, AP0181SH Indoor unit standard ducted unit MMD-AP0271H, AP0961H View Space required for installation and servicing *1Indoor unit high-pressure ducted unit Indoor unit slim duct unit MMD-AP0071SPH, AP0091SPH, AP0121SPH, AP0151SPH, AP0181SPHBottom view complete with filter Bottom view excluding filterIndoor unit ceiling-suspended unit MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481HModel MMC AP0151H, AP0181H AP0241H to AP0271HIndoor unit high-wall unit 1 Series MMK-AP0071H, AP0091H, AP0121HMMK-AP0151H, AP0181H MMK-AP0241H Indoor unit high-wall unit 2 Series MMK-AP0072H, AP0092H, AP0122HIndoor unit floor-mounted console unit MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241HIndoor unit concealed chassis unit No. NameModel MML AP0071BH, AP0091BH, AP0121BH AP0151BH, AP0181HMMF-AP0151H, AP0181H, AP0241H, AP0271H Space required for service For right-hand pipingIndoor unit floor-mounted cabinet unit MMF-AP0361H, AP0481H, AP0561H Refrigerant pipe positions Details of hole for rear pipingRemote controller All dimensions are given in mm Wireless remote controller kit Weekly timerTCB-AX21E RBC-EXW21ECentral remote controller TCB-SC642TLELON Gateway TCB-IFLNTouch-screen controller BMS-TP5120ACE TCS-Net relay interfaceBMS-IFLSV1E Energy monitoring relay interface BMS-IFWH3E Intelligent serverBMS-LSV2E Windows-based central controller BMS-LSV Digital I/O relay interfaceBMS-IFDD01E Outdoor module Outdoor module Two units connected Outdoor unit combination Master unit Slave unit Outdoor module Three units connectedUnit combination Outdoor module Four units connected Unit combination Outdoor unit combination Master unitModel Accessory socket x quantity Branch header/branch jointBranch header RBM-HY1043E, HY1083E, HY2043E,HY2083E Shape branching jointRBM-BY53E, BY103E RBM-BY203E, BY303EAccessory socket Page Toshiba Air Conditioning