Toshiba HFC R-410A manual Technical specifications indoor units

Page 10

4. Technical specifications - indoor units

Model type

Model

Capacity

Cooling

Heating

Height

Width

Depth

Weight

 

name

code

capacity

capacity

mm

mm

mm

kg

 

 

 

kW

kW

 

 

 

 

4-way ceiling cassette

MMU-AP0091H

1

2.8

3.2

256

840

840

20

 

MMU-AP0121H

1.25

3.6

4.0

 

 

 

 

 

MMU-AP0151H

1.7

4.5

5.0

256

840

840

22

 

MMU-AP0181H

2

5.6

6.3

 

 

 

 

 

MMU-AP0241H

2.5

7.1

8.0

256

840

840

23

 

MMU-AP0271H

3

8.0

9.0

 

 

 

 

 

MMU-AP0301H

3.2

9.0

10.0

 

 

 

 

 

MMU-AP0361H

4

11.2

12.5

319

840

840

28

 

MMU-AP0481H

5

14.0

16.0

 

 

 

 

 

MMU-AP0561H

6

16.0

18.0

 

 

 

 

2-way ceiling cassette

MMU-AP0071WH

0.8

2.2

2.5

398

830

550

33

 

MMU-AP0091WH

1

2.8

3.2

 

 

 

 

 

MMU-AP0121WH

1.25

3.6

4.0

 

 

 

 

 

MMU-AP0151WH

1.7

4.5

5.0

398

1350

550

44

 

MMU-AP0181WH

2

5.6

6.3

 

 

 

 

 

MMU-AP0241WH

2.5

7.1

8.0

398

1350

550

48

 

MMU-AP0271WH

3

8.0

9.0

 

 

 

 

 

MMU-AP0301WH

3.2

9.0

10.0

 

 

 

 

 

MMU-AP0481WH

5

14.0

16.0

406

1650

620

52

1-way ceiling cassette

MMU-AP0071YH

0.8

2.2

2.5

235

850

400

22

 

MMU-AP0091YH

1

2.8

3.2

 

 

 

 

 

MMU-AP0121YH

1.25

3.6

4.0

 

 

 

 

 

MMU-AP0151SH

1.7

4.5

5.0

198

1100

655

27

 

MMU-AP0181SH

2

5.6

6.3

 

 

 

 

 

MMU-AP0241SH

2.5

7.1

8.0

198

1200

655

31

Standard ducted unit

MMD-AP0071BH

0.8

2.2

2.5

320

550

800

27

 

MMD-AP0091BH

1

2.8

3.2

 

 

 

 

 

MMD-AP0121BH

1.25

3.6

4.0

 

 

 

 

 

MMD-AP0151BH

1.7

4.5

5.0

320

700

800

30

 

MMD-AP0181BH

2

5.6

6.3

 

 

 

 

 

MMD-AP0241BH

2.5

7.1

8.0

320

1000

800

39

 

MMD-AP0271BH

3

8.0

9.0

 

 

 

 

 

MMD-AP0301BH

3.2

9.0

10.0

 

 

 

 

 

MMD-AP0361BH

4

11.2

12.5

320

1350

800

51

 

MMD-AP0481BH

5

14.0

16.0

 

 

 

 

 

MMD-AP0561BH

6

16.0

18.0

 

 

 

 

High-pressure ducted unit

MMD-AP0181H

2

5.6

6.3

380

850

660

50

 

MMD-AP0241H

2.5

7.1

8.0

380

850

660

52

 

MMD-AP0271H

3

8.0

9.0

 

 

 

 

 

MMD-AP0361H

4

11.2

12.5

380

850

660

56

 

MMD-AP0481H

5

14.0

16.0

380

1200

660

67

 

MMD-AP0721H

8

22.4

25.0

470

1380

1250

155

 

MMD-AP0961H

10

28.0

31.5

 

 

 

 

Slim duct unit

MMD-AP0071SPH

0.8

2.2

2.5

210

845

645

22

 

MMD-AP0091SPH

1

2.8

3.2

 

 

 

22

 

MMD-AP0121SPH

1.25

3.6

4.0

 

 

 

22

 

MMD-AP0151SPH

1.7

4.5

5.0

 

 

 

23

 

MMD-AP0181SPH

2

5.6

6.3

 

 

 

23

Ceiling-suspended unit

MMC-AP0151H

1.7

4.5

5.0

210

910

680

21

 

MMC-AP0181H

2

5.6

6.3

 

 

 

 

 

MMC-AP0241H

2.5

7.1

8.0

210

1180

680

25

 

MMC-AP0271H

3

8.0

9.0

 

 

 

 

 

MMC-AP0361H

4

11.2

12.5

210

1595

680

33

 

MMC-AP0481H

5

14.0

16.0

 

 

 

 

High-wall unit

MMK-AP0071H

0.8

2.2

2.5

368

895

210

18

 

MMK-AP0091H

1

2.8

3.2

 

 

 

 

 

MMK-AP0121H

1.25

3.6

4.0

 

 

 

 

 

MMK-AP0151H

1.7

4.5

5.0

368

1055

210

19

 

MMK-AP0181H

2

5.6

6.3

 

 

 

 

 

MMK-AP0241H

2.5

7.1

8.0

368

1430

210

25

 

MMK-AP0072H

0.8

2.2

2.5

275

790

208

11

 

MMK-AP0092H

1.0

2.8

3.2

 

 

 

 

 

MMK-AP0122H

1.25

3.6

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor-mounted console unit

MML-AP0071H

0.8

2.2

2.5

630

950

230

37

 

MML-AP0091H

1

2.8

3.2

 

 

 

 

 

MML-AP0121H

1.25

3.6

4.0

 

 

 

 

 

MML-AP0151H

1.7

4.5

5.0

 

 

 

 

 

MML-AP0181H

2

5.6

6.3

 

 

 

 

 

MML-AP0241H

2.5

7.1

8.0

630

950

230

40

Concealed chassis unit

MML-AP0071BH

0.8

2.2

2.5

600

745

220

21

 

MML-AP0091BH

1

2.8

3.2

 

 

 

 

 

MML-AP0121BH

1.25

3.6

4.0

 

 

 

 

 

MML-AP0151BH

1.7

4.5

5.0

600

1045

220

29

 

MML-AP0181BH

2

5.6

6.3

 

 

 

 

 

MML-AP0241BH

2.5

7.1

8.0

 

 

 

 

Floor-mounted cabinet unit

MMF-AP0151H

1.7

4.5

5.0

1750

600

210

48

 

MMF-AP0181H

2

5.6

6.3

 

 

 

 

 

MMF-AP0241H

2.5

7.1

8.0

1750

600

210

49

 

MMF-AP0271H

3

8.0

9.0

 

 

 

 

 

MMF-AP0361H

4

11.2

12.5

1750

600

390

65

 

MMF-AP0481H

5

14.0

16.0

 

 

 

 

 

MMF-AP0561H

6

16.0

18.0

 

 

 

 

10

Image 10
Contents Super Modular Multi Page Super Modular Multi System Contents Outline of Toshiba Super Modular Multi System S-MMS Outdoor unit Indoor unit  Largest system capacity  Self-diagnostic system Compact  Energy saving designTechnical specifications combination of outdoor units Summary of system equipmentTechnical specifications outdoor units Branching joints and headersCombined capacity range Outdoor unit model line-up cooling only unitsProduct designation Rated conditionsOutdoor unit model line-up heat pump units MMY- M AP 000 0 H TTechnical specifications indoor units Wireless remote controller kit Connected to indoor unit Remote controllerSimplified remote controller Connected to indoor unit TCB-AX21U W-EController, wired remote controller Weekly timer RBC-EXW21E Connected to central remoteMaster System legend example 8 hp system Basic system configuration8HP Hp system 10HP10HP 10HP Hp system 10HP 10HP 10HP Outdoor unit Indoor unit Remote controller Indoor unit and outdoor unit combination Equipment selection procedureSelection flow chart Capacity codeCapacity correction value Indoor air wet bulb temperature C  Correction of outdoor unit diversity Capacity correction value Indoor air dry bulb temperature C  Correction of outdoor unit diversity Capacity calculation for each indoor unit Operating temperature rangeHeating mode Rated conditionsSelection criteria for each floor Example of equipment selectionOutside view Indoor unit Outdoor unit Model Capacity kW Cooling Heating Procedure and result of equipment selectionAir conditioning load Equipment selection Floor Room No Cooling HeatingExample Equipment selection based on system load profile Load in each roomSchematic diagram MMY-AP2801T8 MMY-AP2801HT8Refrigerant piping design Check of concentration limitFree branching system Line branching system Header branching systemSystem restrictions Allowable length/height difference of refrigerant pipingAllowable value Piping section  Pipe size of outdoor unit Table Model name Selection of refrigerant pipingGas side Liquid side Charge Cooling only Charging requirement with additional refrigerantCalculating the amount of additional refrigerant required Liquid side pipe diameterElectrical wiring design Wiring designOutdoor unit power supply GeneralControl wiring design Type Control wiring diagramControl wiring between outdoor units L5 Wiring LengthDesign FLA MCA MocpVoltage Range Ph-Hz Min Max Compressor Fan motor Power supplySingle outdoor unit Heat pump Cooling only Nominal Combination of outdoor units Heat pump Cooling only NominalControls Control via indoor remote controllerControl via the central remote controller Range of controls to meet various system needsTwo remote controllers Applications for indoor remote controllerBasic function System diagram Model Individual control Control by weekly timerIndoor remote controller Application controls for central remote controllerBasic function System diagram Model Function of central remote controllerAvailable TCB-PCNT30TLEBACnet Application control for networkTCB-1FLN BMS-LSVBMS-TP5120ACE Remote controller AccessoriesIndoor unit accessories Indoor unit type Accessory name Model Applicable modelTechnical specifications Indoor units Way ceiling cassettesRBC-UW136PG RBC-UW266PG Room thermostat RBC-UY135PG RBC-US165PG RBC-US265PGIndoor units Standard ducted units Fan motor power inputStatic pressure factory setting Static pressure max Sound pressure level high/medium/low** dBASound power level high Unit weightStatic pressure factory setting Indoor units High-pressure ducted unitsRear air inlet Sound power level high/medium/low Lower air inlet Sound power level high/medium/lowIndoor units Slim duct units Indoor units Ceiling-suspended units Indoor units High-wall units 1 Series Indoor units High-wall units 2 Series Indoor units Floor-mounted console units Indoor units Concealed chassis units Static pressureIndoor units Floor-mounted cabinet units Outdoor units Outdoor units combination DBA 74.5 DBA 75.0 24.26 Power factor, cooling Operating current, cooling 30.51 258 256 DBA 76.5 77.0 Max. number of connectable indoor units High-pressure switch Power supply ± 10% Ph-Hz 400-3-50 130.0 135.0 MMD-AP0071BH, AP0091BH Fan characteristicsCase of square duct flange of discharge section MMD-AP0121BHMMD-AP0301BH MMD-AP0241BH, AP0271BHMMD-AP0361BH MMD-AP0481BH, AP0561BHMMD-AP0241H, AP0271H High-pressure ducted unitMMD-AP0181H MMD-AP0361HMMD-AP0721H MMD-AP0961HMMD-AP0071SPH, AP0091SPH MMD-AP0121SPH Slim duct unitMMD-AP0151SPH MMD-AP0181SPH Slim duct unit with filter attached MMD-AP0151SPHIndoor unit 4-way ceiling cassette Dimensional drawingsAll dimensions are given in mm MMU-AP0091H to P0561HIndoor unit 2-way ceiling cassette All dimensions are given in mm ViewMMU-AP0071WH, AP0091WH, AP0121WH MMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH, AP0301WH View Space required for installation and servicingModel MMU-AP0151WH to AP0181WH MMU-AP0241WH to AP0301WH MMU-AP0481WH Indoor unit 1-way ceiling cassette MMU-AP0071YH, AP0091YH, AP0121YHView Model MMU AP0151SH, AP0181SH MMU-AP0151SH, AP0181SH, AP0241SHAP0241SH Indoor unit standard ducted unit Indoor unit high-pressure ducted unit View Space required for installation and servicing *1MMD-AP0271H, AP0961H Bottom view complete with filter Indoor unit slim duct unitMMD-AP0071SPH, AP0091SPH, AP0121SPH, AP0151SPH, AP0181SPH Bottom view excluding filterModel MMC AP0151H, AP0181H Indoor unit ceiling-suspended unitMMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H AP0241H to AP0271HIndoor unit high-wall unit 1 Series MMK-AP0071H, AP0091H, AP0121HMMK-AP0151H, AP0181H MMK-AP0241H Indoor unit high-wall unit 2 Series MMK-AP0072H, AP0092H, AP0122HIndoor unit floor-mounted console unit MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241HModel MML AP0071BH, AP0091BH, AP0121BH Indoor unit concealed chassis unitNo. Name AP0151BH, AP0181HIndoor unit floor-mounted cabinet unit Space required for service For right-hand pipingMMF-AP0151H, AP0181H, AP0241H, AP0271H MMF-AP0361H, AP0481H, AP0561H Refrigerant pipe positions Details of hole for rear pipingRemote controller All dimensions are given in mm TCB-AX21E Wireless remote controller kitWeekly timer RBC-EXW21ELON Gateway Central remote controllerTCB-SC642TLE TCB-IFLNBMS-IFLSV1E TCS-Net relay interfaceTouch-screen controller BMS-TP5120ACE BMS-LSV2E Intelligent serverEnergy monitoring relay interface BMS-IFWH3E BMS-IFDD01E Digital I/O relay interfaceWindows-based central controller BMS-LSV Outdoor module Outdoor module Two units connected Unit combination Outdoor module Three units connectedOutdoor unit combination Master unit Slave unit Outdoor module Four units connected Unit combination Outdoor unit combination Master unitBranch header RBM-HY1043E, HY1083E, HY2043E,HY2083E Model Accessory socket x quantityBranch header/branch joint Shape branching jointRBM-BY53E, BY103E RBM-BY203E, BY303EAccessory socket Page Toshiba Air Conditioning