York YCAL0065 DIA Mounting HOLEStyp, 90 9/16, 45 5/16, 21 13/16, 13/16 25 3/8 13 5/8, 15 1/16

Page 35

FORM 150.64-EG1

9/16" DIA MOUNTING HOLES(typ)

1 1/16"

COOLER

END

90 9/16"

END CAP

WIDTH

45 5/16"

ORIGIN

9 13/16"

21 13/16"

TOP VIEW

 

Y

C

X

 

G

 

5 5/16"

38"

CONTROL PANEL

COIL

END

1 1/16"

9 13/16"

 

 

25 3/8"

B

B

 

 

 

 

 

 

 

 

13 5/8"

 

 

 

 

 

 

 

TWO LIFTING HOLES

 

 

 

15 1/16"

 

BOTH SIDES

13 15/16"

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

144 13/16"

 

C

 

X

 

 

 

 

 

 

FRONT VIEW

 

G

 

 

 

 

YORK INTERNATIONAL

35

Image 35
Contents Form 150.64-EG1 AIR-COOLED Scroll ChillersTable of Contents Introduction Cooler SpecificationGeneral CompressorsMillennium Control Center Unit ON/OFF switchPower Panel Control Options Options and AccessoriesPower Options SINGLE-POINT NON-FUSED Disconnect SwitchDX Cooler 300 Psig 21 bar DWP Waterside Condenser and Cabinet OptionsCompressor Acoustic Sound Blanket Each This page intentionally left blank Method of Selection Selection DataGuide to Selection Selection RulesDetermine E.G. GPM Calculate GPMExample Brine Chilling SI Units Ycal Design ParametersEnglish Ycal 100 Water Pressure Drop1000 Model YCAL0051EC Ratings R-22 60Hz English UnitsModel YCAL0041EC Model YCAL0045EC33.4 42.7 32.5 45.2 31.6 47.9 30.7 50.7 29.7 53.7 105 110.0 115.0 120.0 125.031.3 42.2 30.5 44.7 29.6 47.4 28.7 50.2 27.8 53.2 32.4 42.5 31.5 45.0 30.6 47.6 29.7 50.4 28.7 53.4Model YCAL0065EC Model YCAL0055ECModel YCAL0061EC 46.0 59.0 44.7 62.3 43.4 65.8 31.6 48.6 30.6 51.3 42.3 58.2 41.2 61.4 39.9 64.8 29.0 48.0 28.0 50.643.8 58.5 42.6 61.8 41.3 65.2 30.0 48.3 29.0 50.9 45.3 58.8 44.0 62.1 42.7 65.6 31.1 48.5 30.1 51.225.0 30.0 35.0 40.0 45.0 50.0 Ratings R-22 60Hz SI Units172.2 43.1 166.0 47.5 159.3 52.3 152.2 57.7 Ratings R-22 50Hz English Units 45.0 34.8 28.0 37.0 27.2 39.5 26.3 42.1 25.4 44.9 40.0 34.3 25.7 36.5 25.0 39.0 24.1 41.6 23.2 44.442.0 34.5 26.6 36.7 25.8 39.2 25.0 41.8 24.1 44.6 44.0 34.7 27.5 36.9 26.7 39.4 25.9 42.0 24.9 44.834.0 13.5 33.8 13.135.7 12.2 40.0 10.645.0 48.2 38.1 51.0 36.9 54.0 35.8 57.1 34.6 60.5 40.0 47.5 35.0 50.3 33.9 53.3 32.8 56.4 31.7 59.742.0 47.8 36.2 50.6 35.1 53.6 34.0 56.7 32.8 60.0 44.0 48.0 37.4 50.9 36.3 53.8 35.2 57.0 34.0 60.3Ratings R-22 50Hz SI Units 146.1 34.7 140.9 38.4 135.3 42.5 129.3 47.1 Load Tons EER Displ Part Load Ratings R-22 English UnitsFull UnitLoad Scop Displ Part Load Ratings R-22 SILoad COP Displ YCAL055 FullPhysical Data 47400 Per Power ChillerSide Water 87.0125 250 500 1000 2000 4000 8000 DBA Sound Data50Hz Line Frequency Low Noise Fan R-22 Dimensions YCAL0041 English 13/16 DIA Mounting HOLEStyp90 9/16 45 5/160045 63.2 43.7 Dimensions YCAL0045 English0045 59.2 43.5 Copper 13/16 25 3/8 B 13 5/8 20 1/160051 64.3 42.9 Dimensions YCAL0051 English0051 59.2 42.6 Copper Front View 0055 57.9 43.0 Copper Dimensions YCAL0055EC English62 5/8 TYP 15/16 34 11/1615 1/16 144 13/16 18 7/1628 9/16 0061 56.6 45.2 Copper Dimensions YCAL0061 English61 7/8 43 1/825 3/8 28 9/16 43 5/1616 11/16 0065 65.2 44.9 Dimensions YCAL0065 English62 5/8 0065 59.7 44.9 CopperCooler Coil END Dimensions YCAL0041 SI 554 23011150 2490045 1605.9 1109.7 Dimensions YCAL0045 SI0045 1503.5 1105.5 Copper 509 0051 1633.0 1090.8 Dimensions YCAL0051 SI0051 1504.6 1082.4 Copper Cooler END Dimensions -YCAL0055 SI 645 726 1151249 468 131 965Dimensions YCAL0061 SI 249 424 11000065 1655.5 1141.1 Dimensions YCAL0065 SI0065 1517.6 1140.3 Copper TOP View For Units with ALL Point Loads Less Thatn 1404 LBS 637 KG Isolator SelectionsCIP-X ONE Inch Deflection Spring Isolator CROSS-REFERENCE751 to 1651 lbs 341 to 749 kg ND-XNeoprene Isolator CROSS-REFERENCE Up to 751 lbs Up to 341 kg215.9 34.9 355.6 311.2 Isolator Details contdSlrs 12 1/4Intentionally Left Blank Electrical Data Voltage Range Electrical Data 60Hz RLA Electrical Data 50Hz LUG Wire RangeCOMPR. #1 COMPR. #2 Fans Standard Power Supply Wiring Ycal 0014 Power WiringYork International York International Control Wiring Chilled Liquid Piping Application DataUnit Location FoundationInlet Delivery and Handling Guide SpecificationsPart 1 General Quality AssuranceControls Refrigerant Circuit ComponentsHeat Exchangers Accessories and Options Power Connection and DISTRI- ButionYork International Part 3 Execution Installation York International ALL Right