Roberts Gorden CTHN-40, CTHN-200 Common CTHN-Series Components, Tubing and Related Accessories

Page 18

CTHN-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Table 3: Component Package Guide

Model

Tubing Length

Core Packages

Minimum

Standard

Aluminized

 

CTHN-40

10' (3 m)

CP10ALUM

CP10ALUM

CTHN-60

20' (6 m)

CP20HRS

CP20ALUM

 

 

 

 

CTHN-80

20' (6 m)

CP20HRS

CP20ALUM

CTHN-100

30' (9 m)

CP30HRS

CP30ALUM

 

 

 

 

CTHN-125

40' (12 m)

CP40HRS

CP40ALUM

CTHN-150

40' (12 m)

CP40HRS

CP40ALUM

 

 

 

 

CTHN-175

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

CTHN-200

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

 

 

 

 

Additional tubing length may be added to heater.

Any additional tubing lengths are considered as vent length for length determination. Maximum venting length for unitary heater is 45' (13.7 m).

For manifold tubing on multiburner systems, heat-treated aluminized or porcelain coated tubing is required.

Table 4: Common CTHN-Series Components

Part No.

Description

Tubing and Related Accessories

01312700

Coupling, 4" (10 cm) Plain

01312706

Coupling, 6" (15 cm) Plain

0131270I

Coupling, 4" (10 cm) Lined

01331900

Coupling, 4" (10 cm) Damper

E0009356

Coupling, 6" (15 cm) Damper

0133022D

Tee, 4" (10 cm) Coated

01330203

Tee, 4" (10 cm) Aluminized

01330204

Tee, 6" (15 cm) Aluminized

0133092D

Cross, 4" (10 cm) Coated

01330903

Cross, 4" (10 cm) Aluminized

01330904

Cross, 6" (15 cm) Aluminized

01335801

Elbow, 4" (10 cm) Aluminized 90°

T0100320

Elbow, 6" (15 cm) Aluminized 90°

0133580D

Elbow, 4" (10 cm) Coated 90°

01336101

Elbow, 4" (10 cm) Aluminized 45°

0133610D

Elbow, 4" (10 cm) Coated 45°

91409300

Tube, 4" (10 cm) dia Hot Rolled Steel 10' (3 m)

91409403

Tube, 4" (10 cm) dia Non-Heat Treated Aluminized

 

10' (3 m)

 

 

91409408

Tube, 4" (10 cm) dia Heat Treated Aluminized

 

10' (3 m)

91409420

Tube, 6" (15 cm) dia Non-Heat Treated Aluminized

 

10' (3 m)

9141030D

Tube, 4" (10 cm) dia Coated 10' (3 m)

E0009105

Tube, 6" (15 cm) dia 10' (3 m)

 

Heat Treated Aluminized

91418200

Tube Adapter, 6" (15 cm) dia x 4"(10 cm) dia

 

Aluminized

91240010

Tube Hanger, 6" (15 cm)

91308001

Pipe Compound, High Temperature 1lb can

Venting Accessories

01324401 Air Supply Takeoff, 4" (10 cm) Outside

90707501 Air Supply Blower/Power Venter

91409601 Air Flex Duct, 4" (10 cm) Outside (Box of 8 - 8' (2.4 m) sections)

Reflectors and Related Accessories

01329910

Reflector Side Extension Support

03050010

Reflector Support Package (Tubing)

02712700

Reflector Side Extension, 2 Clips, 2 Screws

02750303

Reflector, Aluminum

027503SS

Reflector, Stainless Steel

02750800

Reflector End Cap, Aluminum

027508SS

Reflector End Cap, Stainless Steel

027508SH

Reflector End Cap, Stainless Steel with Hole

02750900

Reflector Joint

027509SS

Reflector Joint, Stainless Steel

027127SS

Reflector Side Extension, Stainless Steel

03090100

Tube and Reflector Hanger

91907302

S-hook

91903201

Turnbuckle

91903300

Spring Hook

91903202

Turnbuckle with Eyebolt

Control Packages and Thermostats

02770002 System Control

05023000 Load Relay Package

90417600 Transformer Relay - SPST (12 A)

90436300 Transformer Relay - DPST (12 A)

90423000 Thermostat, 24 V Low Voltage (Marked 1-5)

90424300 Thermostat Guard

12

Image 18
Contents If you smell gas Roberts-Gordon, LLCPage Roberts-Gordon, LLC Page Table of Figures Page Heater Safety Manpower RequirementsCorrosive Chemicals Installer ResponsibilityWall Tag National Standards and Applicable CodesCombustibles at all times for safety Inches CentimetersONE Side Reflector InchesModel C D UnapprovedInches Centimeters Model UnventedNational Standards and Applicable Codes Heater Descriptions 5.1 Unitary vs. Multiburner Major Components General Suspension Details DescriptionContents of Core and Extension Packages Reflectors and Related Accessories Tubing and Related AccessoriesVenting Accessories Common CTHN-Series ComponentsUnitary Heater Requirements Unitary Heater Design RequirementsLinear Heater Assembly Overview Unitary Linear Heater LayoutsUnitary Linear Layout Overviews 60 18 m Tube Length 70 21 m Tube Length 80 24 m Tube Length Tube Assembly Overview Unitary U-tube Heater LayoutsUnitary U-tube Layout Overviews Description Part Number Burner Tube InstallationTube Clamp Package Installation Tube Clamp PackageCoupling and Tube Assembly Correct Slide BarTurbulator Installation 2 Coupling and Tube AssemblyTurbulator Installation ModelReflector Installation Hanger Burner Tube ReflectorUnitary Linear & U-TUBE Heater Installation Reflector Support Package10 Burner Installation 11 Fan Inlet Plate and Warning TagWith the flame observation 12 Restrictor Plate Installation 13 Fan InstallationModel Fan Assy. P/N Contents of Core and Extension Packages Tubing Related Accessories Component Package GuideMinimum Standard Aluminized 02719105 0522000005221000 02716305Typical Cthn Multiburner System Installation Multiburner System Design RequirementsNumber of Burners Allowed Per Pump Multiburner Design RequirementsBurners Per Pump Burner ModelManifold Diameter Radiant Tube LengthManifold Tube Multiburner System Layouts and Manifold Tube Length RulesFlag Layout Fork Layouts and Manifold Tube Length Rules LayoutFork Layout Herringbone Layout and Manifold Tube Length Rules Herringbone LayoutNut ± 2 5 cm 10 Turbulator Installation 11 Reflector Installation Clip 12 Burner Installation 2 Elbow Installation Optional Heater AccessoriesElbow Package Configuration .1.1 Elbow Installation 3 Reflector Joint Installation