Roberts Gorden CTHN-40, CTHN-200, CTHN-100, CTHN-125 Coupling and Tube Assembly, Correct Slide Bar

Page 26

CTHN-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Step 8.7 Coupling and Tube Assembly

Close coupling

Start slide bar/coupling lock

A with tab.

B onto coupling.

 

Tab

 

 

 

Slide Bar/Coupling Lock

 

 

Wide End

 

 

Coupling

Open

3" (8 cm) to

 

 

 

 

4" (10 cm)

 

Closed

 

 

C Insert tubes into coupling.

D Tighten coupling to join tubes.

 

 

Slide Bar/Coupling Lock

 

Orient coupling so that

Coupling

 

the impact block is in the

 

 

2:00 or 10:00 o’clock

 

 

positions.

Tube

 

Tube

 

 

Tube

Description

Part Number

Coupling

01329600

 

 

Slide Bar/Coupling Lock

01329700

 

Tube

91409XXX

Step 8.7.1 Coupling and Tube Assembly (Continued)

Tighten slide bar as shown below.

 

Drive slide bar until tight.

 

End of slide bar should be

 

within tolerance listed below.

 

± 2" (5 cm)

Correct Slide Bar

Incorrect Slide Bar

Dimensions

 

Position

Repeat Step 8.7, A - D until all tubes are assembled. See Page 21, Step 8.7.2.

NOTE: If coupling is not tight, loss of vacuum can occur.

20

Image 26
Contents If you smell gas Roberts-Gordon, LLCPage Roberts-Gordon, LLC Page Table of Figures Page Heater Safety Manpower RequirementsCorrosive Chemicals Installer ResponsibilityWall Tag National Standards and Applicable CodesCombustibles at all times for safety Inches CentimetersONE Side Reflector InchesModel C D UnapprovedInches Centimeters Model UnventedNational Standards and Applicable Codes Heater Descriptions 5.1 Unitary vs. Multiburner Major Components General Suspension Details DescriptionContents of Core and Extension Packages Reflectors and Related Accessories Tubing and Related AccessoriesVenting Accessories Common CTHN-Series ComponentsUnitary Heater Requirements Unitary Heater Design RequirementsLinear Heater Assembly Overview Unitary Linear Heater LayoutsUnitary Linear Layout Overviews 60 18 m Tube Length 70 21 m Tube Length 80 24 m Tube Length Tube Assembly Overview Unitary U-tube Heater LayoutsUnitary U-tube Layout Overviews Description Part Number Burner Tube InstallationTube Clamp Package Installation Tube Clamp PackageCoupling and Tube Assembly Correct Slide BarTurbulator Installation 2 Coupling and Tube AssemblyTurbulator Installation ModelReflector Installation Hanger Burner Tube ReflectorUnitary Linear & U-TUBE Heater Installation Reflector Support PackageWith the flame observation 10 Burner Installation11 Fan Inlet Plate and Warning Tag Model Fan Assy. P/N 12 Restrictor Plate Installation13 Fan Installation Contents of Core and Extension Packages Minimum Standard Aluminized Tubing Related AccessoriesComponent Package Guide 02719105 0522000005221000 02716305Typical Cthn Multiburner System Installation Multiburner System Design RequirementsNumber of Burners Allowed Per Pump Multiburner Design RequirementsBurners Per Pump Burner ModelManifold Diameter Radiant Tube LengthManifold Tube Multiburner System Layouts and Manifold Tube Length RulesFlag Layout Fork Layouts and Manifold Tube Length Rules LayoutFork Layout Herringbone Layout and Manifold Tube Length Rules Herringbone LayoutNut ± 2 5 cm 10 Turbulator Installation 11 Reflector Installation Clip 12 Burner Installation 2 Elbow Installation Optional Heater AccessoriesElbow Package Configuration .1.1 Elbow Installation 3 Reflector Joint Installation