SECTION 6: MAJOR COMPONENTS
SECTION 6: MAJOR COMPONENTS
FIGURE 11: Major Component Descriptions
Burner with
Tube Gasket
Must be installed with the flame observation window facing down.
Reflector (Aluminum or Stainless Steel)
Alternate overlap as shown on Page 15, Figure 14 or on Page 18, Figure 17. Minimum overlap is 6'' (16 cm).
Burner Tube
Supplied in 10' (3 m) lengths. Burner tube is always the first tube after the burner.
Tube
Hot rolled or heat treated aluminized tube supplied in 10' (3 m) lengths.
Coupling Assembly with Lock
Turbulator
Turbulator must be installed in the last standard section of tube.Turbulator is only required on the
Flex Gas Line with Shut Off Cock
Tube and Reflector Hanger with Clamp Package Position this hanger no more than 4'' (10 cm) away from the burner assembly.
Tube and Reflector Hanger Suspend system from these hangers.
Reflector Support
Strap & Wire Form
Reflector End Cap
Punch out center section to accommodate tube.
Restrictor Plate
Used at fan assembly inlet for unitary heaters only. See fan assembly below.
For more information, refer to the |
Service Manual |
(P/N 127201NA). |
For more information, refer to the
Fan Assembly
Pump Package -
For more information, refer to the
9