Roberts Gorden CTHN-80, CTHN-200, CTHN-100 Reflector Installation, Hanger Burner Tube Reflector

Page 28

CTHN-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Step 8.9 Reflector Installation

NOTE: All radiant tube surfaces must be covered by a reflector, except for a u-tube. Manifold tube may or may not be covered.

Hanger

Burner Tube

Reflector

Description

Part Number

Tube/Reflector Hanger

03090100

 

 

Burner Tube

03051XXX

 

 

Reflector

02750303

 

 

22

Image 28
Contents If you smell gas Roberts-Gordon, LLCPage Roberts-Gordon, LLC Page Table of Figures Page Heater Safety Manpower RequirementsInstaller Responsibility Wall TagCorrosive Chemicals National Standards and Applicable CodesCombustibles at all times for safety Inches CentimetersONE Side Reflector InchesModel C D UnapprovedInches Centimeters Model UnventedNational Standards and Applicable Codes Heater Descriptions 5.1 Unitary vs. Multiburner Major Components General Suspension Details DescriptionContents of Core and Extension Packages Tubing and Related Accessories Venting AccessoriesReflectors and Related Accessories Common CTHN-Series ComponentsUnitary Heater Requirements Unitary Heater Design RequirementsLinear Heater Assembly Overview Unitary Linear Heater LayoutsUnitary Linear Layout Overviews 60 18 m Tube Length 70 21 m Tube Length 80 24 m Tube Length Tube Assembly Overview Unitary U-tube Heater LayoutsUnitary U-tube Layout Overviews Burner Tube Installation Tube Clamp Package InstallationDescription Part Number Tube Clamp PackageCoupling and Tube Assembly Correct Slide Bar2 Coupling and Tube Assembly Turbulator InstallationTurbulator Installation ModelReflector Installation Hanger Burner Tube ReflectorUnitary Linear & U-TUBE Heater Installation Reflector Support Package11 Fan Inlet Plate and Warning Tag 10 Burner InstallationWith the flame observation 13 Fan Installation 12 Restrictor Plate InstallationModel Fan Assy. P/N Contents of Core and Extension Packages Component Package Guide Tubing Related AccessoriesMinimum Standard Aluminized 05220000 0522100002719105 02716305Typical Cthn Multiburner System Installation Multiburner System Design RequirementsMultiburner Design Requirements Burners Per PumpNumber of Burners Allowed Per Pump Burner ModelRadiant Tube Length Manifold TubeManifold Diameter Multiburner System Layouts and Manifold Tube Length RulesFlag Layout Fork Layouts and Manifold Tube Length Rules LayoutFork Layout Herringbone Layout and Manifold Tube Length Rules Herringbone LayoutNut ± 2 5 cm 10 Turbulator Installation 11 Reflector Installation Clip 12 Burner Installation Optional Heater Accessories Elbow Package Configuration .1.1 Elbow Installation2 Elbow Installation 3 Reflector Joint Installation