Lochinvar 065, 495 service manual Domestic Water Heaters, Save this manual for future reference

Page 1

CB-CW(E)-i&s-06

INSTALLATION AND SERVICE MANUAL

HYDRONIC HEATING BOILERS and

DOMESTIC WATER HEATERS

495,000 - 2,065,000 Btu/hr MODELS

￿WARNING: Do not use this appliance if any part has been under water. The possible damage to a flooded appliance can be extensive and present numerous safety hazards. Any appliance that has been under water must be replaced.

￿WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, exposure to hazardous materials or loss of life. Refer to this manual. Installation and service must be performed by a qualified installer, service agency or the gas supplier. This unit contains materials that have been identified as carcinogenic, or possibly carcinogenic, to humans.

￿WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a

neighbors phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Save this manual for future reference.

Image 1
Contents Save this manual for future reference Domestic Water HeatersHydronic Heating Boilers and Domestic Water Heaters General Product Information Safety InformationHydronic Heating Boilers and Domestic Water Heaters Front and Rear View Product IdentificationClearances from Combustible Construction InstallationBase for Combustible Floors Hydronic System Antifreeze Outdoor Boiler InstallationShut-Down and Draining Pump OperationFreeze Protection for a Heating Boiler System if required Installing Combustion Air FilterCombustion Air Filter One Opening Combustion Air OptionsGeneral Information Installation VentingExhaust Fans Venting SupportTABLE-A Table B Vent System OptionsFlue Pipe Sizes TABLE-CNegative Draft Conventional Negative Draft VentingFlue Outlet Piping Common Venting SystemsMasonry Chimney Installations Outdoor Installation VentingOutdoor Vent Kits Table DOutdoor Vent/Air Inlet Location Outdoor Vent KitGas Piping Gas Pressure TestInput Max Min Gas Train and Controls Connecting Gas Piping to UnitChecking Gas Supply Pressure Combination Gas ValvesVenting of Combination Gas Valves Measuring Gas Supply Pressure at Combination Gas Valve Gas Manifold Pressure AdjustmentRegulator Pressure Less Front Chamber Pressure NET Manifold PressureLow Water Cutoff Water Flow SwitchRelief Valve If EquippedTable J Terminal Strip Connection OptionsNominal AMP Draw Data General Plumbing Rules Water Connections Heating Boilers OnlyPrimary/Secondary Boiler Piping Radiant Floor and Snow Melt Heating Systems Low Temperature Return Water SystemsInput LTV Valve Kit Btu/hr System Temperature Rise Chart Based on Btu/hr Input Installation with a Chilled Water SystemTable L 10ºF 20ºF 30ºF 40ºF 50ºF 60ºFBoiler Flow Rate Temperature/Pressure GaugeBoiler Bypass Requirements Filling the SystemLighting Instructions OperationTo Turn Off Gas To Appliance Locating Temperature ControlTable M Temperature Control SettingsSet Point Maximum Set Point DeterminationHigh-Fire Offset Outdoor Air Reset OptionShutdown Outdoor Air Max O.A. MaxPlacement of Sensors Temperature Control SensorsBoiler Application Water Heater ApplicationWire Maximum Gauge Remote Wire ConnectionHot Surface Igniter and Ignition Control Module Table NHot Surface Ignition Control Module Diagnostic Status IndicationIgnition and Control Timings Ignition Module Lockout FunctionsTable O Status LED Diagnostic CodesTable P Temperature Rise Chart Required Temperature RiseDomestic Water Heaters Water Velocity ControlWater Chemistry Pipe Sizing ChartCirculating Pump Table RDomestic Water Temperatures Potable Hot Water Temperature Control SettingsDomestic Water Minimum Pump PerformanceLocation of Cold Water Supply Piping Connections High Water Temperature Limit ControlOptional Relief Valve Thermal ExpansionFlue Gas Passageways Cleaning Procedures Cleaning MaintenanceElectrical Heat Exchanger CleaningCombustion and Ventilation Air Set Up Procedure Cleaning and MaintenanceAdjustment Procedure 495,000 1,255,000 Btu/hr Models Servicing Hot Surface Igniter and Ignition Module Ignition System Checkout Sequence of OperationON/OFF Rocker Switch Power SupplyManual Reset High-Limit Thermostat Safety Device TerminalsIgnition Module Electronic Temperature ControllerHeat Transfer Process Gas Valves, Burner BTU/HR Schematic DiagramHI-LIMITS PWR SW Main Unit GAS Valves Blower Pressure Switch 15AMPS Wiring DiagramControl BOX Connections Control BOX Connections

000 - 2, 065, 495 specifications

Lochinvar 000 - 2,495,065 is a cutting-edge water heating solution designed to meet the needs of modern residential and commercial applications. This high-efficiency unit combines advanced engineering with robust technologies, providing unmatched performance and reliability.

One of the standout features of the Lochinvar 000 - 2,495,065 is its high thermal efficiency, which often exceeds 95%. Utilizing condensing technology, the unit harnesses heat from exhaust gases, allowing it to recover otherwise lost energy, thereby reducing operational costs significantly. This efficiency not only lowers energy bills for users but also lessens the environmental impact by minimizing greenhouse gas emissions.

The Lochinvar 000 - 2,495,065 is equipped with a lightweight stainless steel heat exchanger. This construction ensures exceptional corrosion resistance and longevity, extending the lifespan of the unit while maintaining optimal performance. The stainless steel design also contributes to faster heating times, making it ideal for high-demand environments.

In terms of control technologies, the Lochinvar 000 - 2,495,065 features an intuitive touchscreen interface. This user-friendly design allows for seamless operation, real-time monitoring, and easy adjustments to temperature settings. Additionally, it facilitates remote diagnostics, promoting efficient maintenance and reducing downtime, which is crucial for busy facilities.

For enhanced safety, the Lochinvar 000 - 2,495,065 includes multiple safety mechanisms, such as over-temperature protection, flame safeguard, and leak detection systems. These safety features ensure secure operation and give users peace of mind.

Moreover, the unit is compatible with various fuel sources, including natural gas and propane, making it versatile and adaptable to different infrastructure requirements. This flexibility ensures that the Lochinvar 000 - 2,495,065 can be integrated into various settings, from residential homes to large commercial buildings.

Another significant characteristic is its compact design, allowing for easy installation in tight spaces. The footprint of the Lochinvar 000 - 2,495,065 makes it an ideal solution for applications where space is at a premium, without compromising on performance.

In summary, Lochinvar 000 - 2,495,065 represents a premium choice for water heating solutions, merging advanced technologies, high efficiency, and user-friendly design to cater to a wide range of heating needs while ensuring safety and sustainability.