Lochinvar 000 - 2, 495, 065 To Turn Off Gas To Appliance, Locating Temperature Control

Page 29

Installation and Service Manual

Figure 31 - Control Panel Cover

Figure 32 - ON/OFF Switch

8.Turn the manual gas cock clockwise to the “OFF” position.

9.Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information. If you do not smell gas, go on to the next step.

10.Turn the manual gas cock counterclockwise to the “ON” position.

11.Turn the power switch to the “ON” position.

12.Reinstall the control panel cover. Tighten the knurled knob at the bottom of the control panel cover.

13.If the unit will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

To Turn Off Gas To Appliance

1.Remove the control panel cover to access control panel.

2.Turn power switch to "OFF" position.

3.Turn the manual gas cock clockwise to the "OFF" position.

￿WARNING: Should overheating occur or the gas fail to shut off, turn off the manual gas control valve to the unit.

Figure 33 - Combination Gas Valve

SETTING TEMPERATURE CONTROL

Note: The temperature controller is preset at the factory with test settings. You may need to adjust the settings to meet your specific needs.

￿WARNING: Return water temperatures must not be less than 140°F. If lower return water temperatures are required, follow the instructions for Low Temperature Return Water Systems on page 25.

Locating Temperature Control

The temperature control is located behind the combustion air inlet panel on the left front of the unit (see Figure 34). Follow the steps below to access the temperature control.

1.Loosen the knurled knob at the bottom of the control panel cover.

2.Pull the bottom of the panel out and down to remove.

29

Image 29
Contents Save this manual for future reference Domestic Water HeatersHydronic Heating Boilers and Domestic Water Heaters General Product Information Safety InformationHydronic Heating Boilers and Domestic Water Heaters Front and Rear View Product IdentificationBase for Combustible Floors InstallationClearances from Combustible Construction Hydronic System Antifreeze Outdoor Boiler InstallationShut-Down and Draining Pump OperationCombustion Air Filter Installing Combustion Air FilterFreeze Protection for a Heating Boiler System if required One Opening Combustion Air OptionsGeneral Information Installation VentingExhaust Fans Venting SupportTABLE-A Table B Vent System OptionsFlue Pipe Sizes TABLE-CNegative Draft Conventional Negative Draft VentingFlue Outlet Piping Common Venting SystemsMasonry Chimney Installations Outdoor Installation VentingOutdoor Vent Kits Table DOutdoor Vent/Air Inlet Location Outdoor Vent KitInput Max Min Gas Pressure TestGas Piping Gas Train and Controls Connecting Gas Piping to UnitVenting of Combination Gas Valves Combination Gas ValvesChecking Gas Supply Pressure Measuring Gas Supply Pressure at Combination Gas Valve Gas Manifold Pressure AdjustmentRegulator Pressure Less Front Chamber Pressure NET Manifold PressureLow Water Cutoff Water Flow SwitchRelief Valve If EquippedNominal AMP Draw Data Terminal Strip Connection OptionsTable J General Plumbing Rules Water Connections Heating Boilers OnlyPrimary/Secondary Boiler Piping Input LTV Valve Kit Btu/hr Low Temperature Return Water SystemsRadiant Floor and Snow Melt Heating Systems System Temperature Rise Chart Based on Btu/hr Input Installation with a Chilled Water SystemTable L 10ºF 20ºF 30ºF 40ºF 50ºF 60ºFBoiler Flow Rate Temperature/Pressure GaugeBoiler Bypass Requirements Filling the SystemLighting Instructions OperationTo Turn Off Gas To Appliance Locating Temperature ControlTable M Temperature Control SettingsSet Point Maximum Set Point DeterminationHigh-Fire Offset Outdoor Air Reset OptionShutdown Outdoor Air Max O.A. MaxPlacement of Sensors Temperature Control SensorsBoiler Application Water Heater ApplicationWire Maximum Gauge Remote Wire ConnectionHot Surface Igniter and Ignition Control Module Table NHot Surface Ignition Control Module Diagnostic Status IndicationIgnition and Control Timings Ignition Module Lockout FunctionsTable P Status LED Diagnostic CodesTable O Temperature Rise Chart Required Temperature RiseDomestic Water Heaters Water Velocity ControlWater Chemistry Pipe Sizing ChartCirculating Pump Table RDomestic Water Temperatures Potable Hot Water Temperature Control SettingsDomestic Water Minimum Pump PerformanceLocation of Cold Water Supply Piping Connections High Water Temperature Limit ControlOptional Relief Valve Thermal ExpansionFlue Gas Passageways Cleaning Procedures Cleaning MaintenanceCombustion and Ventilation Air Heat Exchanger CleaningElectrical Adjustment Procedure 495,000 1,255,000 Btu/hr Models Cleaning and MaintenanceSet Up Procedure Servicing Hot Surface Igniter and Ignition Module Ignition System Checkout Sequence of OperationON/OFF Rocker Switch Power SupplyManual Reset High-Limit Thermostat Safety Device TerminalsHeat Transfer Process Gas Valves, Burner Electronic Temperature ControllerIgnition Module BTU/HR Schematic DiagramHI-LIMITS PWR SW Main Unit GAS Valves Blower Pressure Switch 15AMPS Wiring DiagramControl BOX Connections Control BOX Connections

000 - 2, 065, 495 specifications

Lochinvar 000 - 2,495,065 is a cutting-edge water heating solution designed to meet the needs of modern residential and commercial applications. This high-efficiency unit combines advanced engineering with robust technologies, providing unmatched performance and reliability.

One of the standout features of the Lochinvar 000 - 2,495,065 is its high thermal efficiency, which often exceeds 95%. Utilizing condensing technology, the unit harnesses heat from exhaust gases, allowing it to recover otherwise lost energy, thereby reducing operational costs significantly. This efficiency not only lowers energy bills for users but also lessens the environmental impact by minimizing greenhouse gas emissions.

The Lochinvar 000 - 2,495,065 is equipped with a lightweight stainless steel heat exchanger. This construction ensures exceptional corrosion resistance and longevity, extending the lifespan of the unit while maintaining optimal performance. The stainless steel design also contributes to faster heating times, making it ideal for high-demand environments.

In terms of control technologies, the Lochinvar 000 - 2,495,065 features an intuitive touchscreen interface. This user-friendly design allows for seamless operation, real-time monitoring, and easy adjustments to temperature settings. Additionally, it facilitates remote diagnostics, promoting efficient maintenance and reducing downtime, which is crucial for busy facilities.

For enhanced safety, the Lochinvar 000 - 2,495,065 includes multiple safety mechanisms, such as over-temperature protection, flame safeguard, and leak detection systems. These safety features ensure secure operation and give users peace of mind.

Moreover, the unit is compatible with various fuel sources, including natural gas and propane, making it versatile and adaptable to different infrastructure requirements. This flexibility ensures that the Lochinvar 000 - 2,495,065 can be integrated into various settings, from residential homes to large commercial buildings.

Another significant characteristic is its compact design, allowing for easy installation in tight spaces. The footprint of the Lochinvar 000 - 2,495,065 makes it an ideal solution for applications where space is at a premium, without compromising on performance.

In summary, Lochinvar 000 - 2,495,065 represents a premium choice for water heating solutions, merging advanced technologies, high efficiency, and user-friendly design to cater to a wide range of heating needs while ensuring safety and sustainability.