EXTERNAL AUXILIARY BYPASS VALVE (Where required)

An auxiliary bypass valve should be used when flow rates exceed 60 GPM (usually a high performance pump size larger than 1 1/2 HP will exceed this flow rate). This valve is required to complement the function of the automatic bypass valve, particularly when start- ing the heater in winter or early spring when the spa or pool temperature is down below 55°F. It also serves to eliminate needless pressure drop through the heater and accompanying reduction in the flow rate to the spa jets, etcetera.

From Heater To Heater

To Pool

From Pool

Auxiliary Bypass Valve (do not use gate valve)

Fig. # 8150.0s

AUXILIARY BYPASS VALVE ADJUSTMENT

To set bypass: With clean filter, adjustment is made by feeling the inlet and outlet pipes at the heater. Outlet pipes should be slightly warmer than inlet and comfortable to the touch. If pipe is hot, close bypass; if cold, open bypass

PRESSURE RELIEF VALVE INSTALLATION

To conform to local building codes, it may be necessary to install a pressure relief valve. A 3/4" pressure relief valve having a capacity equal to BTU/ HR output of the model to be installed is recommended for this appliance.

Drain Pipe

Drain Pipe

throughout its entire length and must pitch downward from the valve. No shut-off valve shall be installed between the relief valve and the drain line. Valve lever should be tripped at least once a year to ensure that waterways are clear.

ELECTRICAL WIRING

NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105 °C wire or its equivalent, except all black wire must be replaced with 150 °C wire or its equivalent.

MILLIVOLT SYSTEM

The Millivolt System Residential Heater is equipped with a self-generating electrical system in which the electric current is provided by means of a pilot generator. No external electrical connections are required.

ELECTRONIC INTERMITTENT IGNITION DEVICE SYSTEM (IID)

NOTE: When the electrical hookup to the heater requires both 24V and 115V or 240V, each input voltage must be isolated in separate conduit.

The Electronic Intermittent Ignition Device auto- matically lights the pilot and main burners upon a call for the heat. The heater is supplied with a dual voltage transformer for 120V or 240V input power hookup.

NOTE: IID Propane Units Only

Heater is equipped with an electronic ignition device with a 100% safety lockout feature. If the heater fails to start or lockout. Reset the ignition device by inter- rupting the power to the heater for 60 seconds.

CAUTION: If service replacement of the electronic ignition device is required. Replace only with a 100% safety lockout device with 90 second trial for pilot ignition.

Heater Outlet

Heater Outlet

 

 

Fig. # 8157.0s

 

NOTE: To avoid water damage or scalding due to valve

 

operation, drain pipe must be connected to valve outlet

 

and run to a safe place of discharge. Drain pipe must be

 

the same size as the valve discharge connection

Fig. # 8929.1

Robertshaw Intermittent

Ignition Device

Fig. # 8085

Honeywell Intermittent

Ignition Device

13

Image 14
Contents Versa What to do if YOU Smell GASContents Before START-UP Burners For Your Safety Read Before OperatingSTART-UP Procedures WaterTo Turn OFF GAS to Appliance Millivolt SystemLighting Instructions Electronic Ignition Systems Operating InstructionsAfter START-UP Maintenance Care ProceduresWater Pressure Switch Visual InspectionCold Weather Operation Basic Tips if Heater will not FirePool & SPA Water Chemistry Winterizing the SPA HeaterReceiving Equipment General SpecificationInstallation Instructions ALL Heaters Outdoor HeatersStep Indoor HeatersVenting Connections Vent Piping GAS Pressure Regulator GAS Supply ConnectionsModel Robertshaw MVCompanion Flange Connections Plumbing for Water Connections LocationFlow Rates Automatic Chlorinators and Chemical FeedersElectrical Wiring Millivolt System Auxiliary Bypass Valve AdjustmentPressure Relief Valve Installation Electronic Intermittent Ignition Device System IIDWiring Diagram KEY Fig. #9240Wiring Diagram Millivolt Units With Mechanical Thermostat Wiring Diagram Millivolt Units With Solid State ThermostatWiring Diagram 152178 Model 055 IID Pressure Switch CONTROLS/ADJUSTMENTS/REPLACEMENTSTemperature Controls Servicing InstructionsTWO Speed Pumps Pressure Switch Adjustment Flame ROLL-OUT Safety SwitchHigh Limits High Limit RemovalGAS Valve Removal Pilot Removal and CleaningBurner Drawer Removal Main Burner and Orifice RemovalCombustion Chamber Removal Desooting ProcedureUnitherm Governor U.G. Replacement Control Immersion Well ReplaceTrouble Shooting Guide Liming Bypassing too much water Electrical Solid State Thermostat Millivolt Measured and Estimated Resistance Match Within 20 PercentHigh Voltage Troubleshooting Honeywell S8600Electrical Electronic Ignition IID Electrical Solid State Thermostat IID Voltage Between 21.5-28.5Replacement Parts List RAYPAK, INC Agoura Road Westlake VILLAGE, CAIID 13-P 14-P 15-PPage Page Warranty Conditions

055B specifications

The Raypak 055B is a high-performance pool and spa heater recognized for its efficiency, reliability, and advanced technologies tailored to meet the needs of consumers. Its compact design and powerful heating capabilities ensure that users enjoy warm water conditions regardless of the outdoor temperature.

One of the main features of the Raypak 055B is its exceptional heating output. With a power rating that can efficiently heat both pools and spas, this model is designed for performance. The heater's efficient heat exchanger is constructed from copper that enhances the transfer of heat, allowing for rapid heating while optimizing energy use. This results in lower utility bills and a smaller environmental footprint.

The Raypak 055B incorporates innovative technology that enhances user experience. It features a digital display that allows for precise temperature control and easy adjustments. Users can set the desired temperature and monitor energy usage, ensuring they achieve the perfect balance between comfort and efficiency. The built-in diagnostic system helps users troubleshoot any issues quickly, maintaining the heater's performance and prolonging its lifespan.

Another significant characteristic of the Raypak 055B is its reliability. The heater is designed with a durable, rust-resistant cabinet that protects the internal components from the elements. This rugged construction makes the Raypak 055B an excellent choice for outdoor installations, ensuring longevity and reliable operation year-round.

The advanced airflow design in the Raypak 055B ensures a safe and efficient operation. The heater is equipped with a standard fan that aids in efficient operation while minimizing noise. Additionally, its low NOx emissions technology meets strict environmental regulations, making it an environmentally friendly option.

The Raypak 055B also includes an innovative ignition system for enhanced safety and convenience. The direct spark ignition eliminates the need for a standing pilot light, reducing gas consumption and further improving efficiency. The unit's freeze protection feature prevents damage during harsh winter conditions, ensuring that users can rely on it throughout the seasons.

In conclusion, the Raypak 055B stands out as a top choice for pool and spa heating solutions. With its combination of efficiency, durability, and advanced technology, it meets the demands of modern consumers looking for comfort without compromising on performance or sustainability. Whether you need to heat a residential pool or a commercial spa, the Raypak 055B is engineered to deliver exceptional results.