Raypak 055B installation instructions Electronic Ignition Systems, Operating Instructions

Page 5

CAUTION: Propane gas is heavier than air and will settle on the ground. Since propane can accumulate in confined areas, extra care should be exercised when lighting propane heaters.

OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES

AUTOMATICALLY LIGHTED PILOTS

(ELECTRONIC IGNITION SYSTEMS)

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS: *Do not try to light any appliance.

*Do not touch any electric switch; do not use any phone in your building.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it; call a qualified service technician. Force or attempted repair may result in fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to re- place any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

5.Remove heater door panel.

6.Push in gas control knob slightly and turn clock-

wise to "Off".

Knob cannot be turned to "Off" unless it is pushed in slightly. Do not force.

7.Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety infor- mation previously stated. If you don't smell gas, go to the next step.

Gas control lever shown in the "On" position.

8.Turn gas control knob counterclockwise to "On".

Gas control knob shown in "ON" position.

GAS VALVE-IID

Fig. # 8112

9.Replace heater door panel.

10.Turn on all electrical power to appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat at the lowest setting.

2.Turn off all the electric power to the appliance if service is to be performed.

3.Remove heater door panel.

4. Push in gas control knob slightly and turn

clockwise to "Off".

5. Replace heater door panel.

4

Image 5
Contents What to do if YOU Smell GAS VersaContents START-UP Procedures For Your Safety Read Before OperatingBefore START-UP Burners WaterTo Turn OFF GAS to Appliance Millivolt SystemLighting Instructions Operating Instructions Electronic Ignition SystemsWater Pressure Switch Maintenance Care ProceduresAfter START-UP Visual InspectionPool & SPA Water Chemistry Basic Tips if Heater will not FireCold Weather Operation Winterizing the SPA HeaterReceiving Equipment General SpecificationInstallation Instructions Outdoor Heaters ALL HeatersStep Indoor HeatersVenting Connections Vent Piping Model GAS Supply ConnectionsGAS Pressure Regulator Robertshaw MVFlow Rates Plumbing for Water Connections LocationCompanion Flange Connections Automatic Chlorinators and Chemical FeedersPressure Relief Valve Installation Auxiliary Bypass Valve AdjustmentElectrical Wiring Millivolt System Electronic Intermittent Ignition Device System IIDFig. #9240 Wiring Diagram KEYWiring Diagram Millivolt Units With Solid State Thermostat Wiring Diagram Millivolt Units With Mechanical ThermostatWiring Diagram 152178 Model 055 IID Temperature Controls CONTROLS/ADJUSTMENTS/REPLACEMENTSPressure Switch Servicing InstructionsHigh Limits Pressure Switch Adjustment Flame ROLL-OUT Safety SwitchTWO Speed Pumps High Limit RemovalBurner Drawer Removal Pilot Removal and CleaningGAS Valve Removal Main Burner and Orifice RemovalUnitherm Governor U.G. Replacement Desooting ProcedureCombustion Chamber Removal Control Immersion Well ReplaceTrouble Shooting Guide Liming Bypassing too much water Measured and Estimated Resistance Match Within 20 Percent Electrical Solid State Thermostat MillivoltHigh Voltage Troubleshooting Honeywell S8600Electrical Electronic Ignition IID Voltage Between 21.5-28.5 Electrical Solid State Thermostat IIDRAYPAK, INC Agoura Road Westlake VILLAGE, CA Replacement Parts List13-P 14-P 15-P IIDPage Page Warranty Conditions

055B specifications

The Raypak 055B is a high-performance pool and spa heater recognized for its efficiency, reliability, and advanced technologies tailored to meet the needs of consumers. Its compact design and powerful heating capabilities ensure that users enjoy warm water conditions regardless of the outdoor temperature.

One of the main features of the Raypak 055B is its exceptional heating output. With a power rating that can efficiently heat both pools and spas, this model is designed for performance. The heater's efficient heat exchanger is constructed from copper that enhances the transfer of heat, allowing for rapid heating while optimizing energy use. This results in lower utility bills and a smaller environmental footprint.

The Raypak 055B incorporates innovative technology that enhances user experience. It features a digital display that allows for precise temperature control and easy adjustments. Users can set the desired temperature and monitor energy usage, ensuring they achieve the perfect balance between comfort and efficiency. The built-in diagnostic system helps users troubleshoot any issues quickly, maintaining the heater's performance and prolonging its lifespan.

Another significant characteristic of the Raypak 055B is its reliability. The heater is designed with a durable, rust-resistant cabinet that protects the internal components from the elements. This rugged construction makes the Raypak 055B an excellent choice for outdoor installations, ensuring longevity and reliable operation year-round.

The advanced airflow design in the Raypak 055B ensures a safe and efficient operation. The heater is equipped with a standard fan that aids in efficient operation while minimizing noise. Additionally, its low NOx emissions technology meets strict environmental regulations, making it an environmentally friendly option.

The Raypak 055B also includes an innovative ignition system for enhanced safety and convenience. The direct spark ignition eliminates the need for a standing pilot light, reducing gas consumption and further improving efficiency. The unit's freeze protection feature prevents damage during harsh winter conditions, ensuring that users can rely on it throughout the seasons.

In conclusion, the Raypak 055B stands out as a top choice for pool and spa heating solutions. With its combination of efficiency, durability, and advanced technology, it meets the demands of modern consumers looking for comfort without compromising on performance or sustainability. Whether you need to heat a residential pool or a commercial spa, the Raypak 055B is engineered to deliver exceptional results.