Raypak 055B Electrical Solid State Thermostat IID, Voltage Between 21.5-28.5

Page 26

ELECTRICAL (SOLID STATE THERMOSTAT IID)

If the pool/spa/hot tub water is too cold, troubleshoot the system as follows:

Check voltage at 24 V terminals.

VOLTAGE BETWEEN 21.5-28.5 V.

Set control to max. temperature. After 2-3 cycles, check water temperature.

VOLTAGE OUTSIDE RANGE 21.5-28.5 V. Check transformer, 120 V supply, correct as necessary

TEMPERATURE BELOW 105°F Disconnect sensor leads from circuit board. Measure sensor resistance with ohmmeter.

TEMPERATURE 105-106° F. Control ok.

RESISTANCE 1-14k OHMS.

Check water temperature; estimate expected sensor resistance from chart below.

RESISTANCE O OHMS (SHORT CIRCUIT) Check system for shorted wires or open circuits. Replace sensor if necessary.

MEASURED AND ESTIMATED RESISTANCE MATCH WITHIN 20 PERCENT.

Disconnect potentiometer leads from circuit board. Measure resistance with ohmmeter. If resistance is:

0-100 ohms at minimum setting;

9k to 11k at maximum setting,

replace circuit board. Above 11k ohms but less than

15 k ohms, replace potentiometer.

Above 15k ohms, fix loose or broken wires; replace potentiometer if necessary.

Reconnect all leads and check out system.

MEASURED AND ESTIMATED RESISTANCE DON'T MATCH.

Replace sensor. Reconnect all leads and check out system.

If the pool/spa/hot tub water is too hot, troubleshoot the system as follows:

Check voltage at 24 V terminals.

 

 

 

 

 

 

 

 

VOLTAGE BETWEEN 21.5-28.5 V.

 

VOLTAGE OUTSIDE RANGE 21.5-28.5 V.

Set control to max. temperature. After 2-3

 

Check transformer, 120 V supply, correct as

cycles, check water temperature.

 

necessary.

 

 

 

 

 

 

 

 

TEMPERATURE ABOVE 108°F Disconnect sensor leads from circuit board. Measure sensor resistance with ohmmeter.

TEMPERATURE 105-106° F. Control ok.

 

 

 

 

 

 

 

 

 

 

RESISTANCE 1-14k OHMS.

 

RESISTANCE ABOVE 15k OHMS (OPEN

 

Check water temperature; estimate expected

 

CIRCUIT) OR SHORT CIRCUIT.

 

sensor resistance from chart below.

 

Fix loose or broken wires. Replace sensor if

 

 

 

 

 

necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEASURED AND ESTIMATED RESISTANCE

 

 

MEASURED AND ESTIMATED RESISTANCE

 

MATCH WITHIN 20 PERCENT.

 

 

DON'T MATCH.

 

Disconnect potentiometer leads from circuit board.

 

 

Replace sensor. Reconnect all leads and check

 

Measure resistance with ohmmeter. If resistance

 

 

out system.

 

is:

 

 

 

 

 

 

 

 

 

 

 

 

 

0-100 ohms at minimum setting:

 

 

 

 

 

 

 

9k to 11k at maximum setting,

 

 

 

 

 

 

 

replace circuit board.

 

 

 

 

 

 

 

Above 11k ohms, replace

 

 

 

 

 

 

 

potentiometer.

 

 

 

 

 

 

 

0 ohms (short circuit), replace

 

 

 

 

 

 

 

potentiometer.

 

 

 

 

 

 

 

Reconnect all leads and check out system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR RESISTANCE AT VARIOUS TEMPERATURES

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

(deg. F)

61

68

70

77

86

88

95

104

106

 

 

Resistance (k ohms)

14.92

12.49

11.88

10.00

8.06

7.69

6.53

5.33

5.10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

Image 26
Contents Versa What to do if YOU Smell GASContents Before START-UP Burners For Your Safety Read Before OperatingSTART-UP Procedures WaterTo Turn OFF GAS to Appliance Millivolt SystemLighting Instructions Electronic Ignition Systems Operating InstructionsAfter START-UP Maintenance Care ProceduresWater Pressure Switch Visual InspectionCold Weather Operation Basic Tips if Heater will not FirePool & SPA Water Chemistry Winterizing the SPA HeaterReceiving Equipment General SpecificationInstallation Instructions ALL Heaters Outdoor HeatersStep Indoor HeatersVenting Connections Vent Piping GAS Pressure Regulator GAS Supply ConnectionsModel Robertshaw MVCompanion Flange Connections Plumbing for Water Connections LocationFlow Rates Automatic Chlorinators and Chemical FeedersElectrical Wiring Millivolt System Auxiliary Bypass Valve AdjustmentPressure Relief Valve Installation Electronic Intermittent Ignition Device System IIDWiring Diagram KEY Fig. #9240Wiring Diagram Millivolt Units With Mechanical Thermostat Wiring Diagram Millivolt Units With Solid State ThermostatWiring Diagram 152178 Model 055 IID Pressure Switch CONTROLS/ADJUSTMENTS/REPLACEMENTSTemperature Controls Servicing InstructionsTWO Speed Pumps Pressure Switch Adjustment Flame ROLL-OUT Safety SwitchHigh Limits High Limit RemovalGAS Valve Removal Pilot Removal and CleaningBurner Drawer Removal Main Burner and Orifice RemovalCombustion Chamber Removal Desooting ProcedureUnitherm Governor U.G. Replacement Control Immersion Well ReplaceTrouble Shooting Guide Liming Bypassing too much water Electrical Solid State Thermostat Millivolt Measured and Estimated Resistance Match Within 20 PercentHigh Voltage Troubleshooting Honeywell S8600Electrical Electronic Ignition IID Electrical Solid State Thermostat IID Voltage Between 21.5-28.5Replacement Parts List RAYPAK, INC Agoura Road Westlake VILLAGE, CAIID 13-P 14-P 15-PPage Page Warranty Conditions

055B specifications

The Raypak 055B is a high-performance pool and spa heater recognized for its efficiency, reliability, and advanced technologies tailored to meet the needs of consumers. Its compact design and powerful heating capabilities ensure that users enjoy warm water conditions regardless of the outdoor temperature.

One of the main features of the Raypak 055B is its exceptional heating output. With a power rating that can efficiently heat both pools and spas, this model is designed for performance. The heater's efficient heat exchanger is constructed from copper that enhances the transfer of heat, allowing for rapid heating while optimizing energy use. This results in lower utility bills and a smaller environmental footprint.

The Raypak 055B incorporates innovative technology that enhances user experience. It features a digital display that allows for precise temperature control and easy adjustments. Users can set the desired temperature and monitor energy usage, ensuring they achieve the perfect balance between comfort and efficiency. The built-in diagnostic system helps users troubleshoot any issues quickly, maintaining the heater's performance and prolonging its lifespan.

Another significant characteristic of the Raypak 055B is its reliability. The heater is designed with a durable, rust-resistant cabinet that protects the internal components from the elements. This rugged construction makes the Raypak 055B an excellent choice for outdoor installations, ensuring longevity and reliable operation year-round.

The advanced airflow design in the Raypak 055B ensures a safe and efficient operation. The heater is equipped with a standard fan that aids in efficient operation while minimizing noise. Additionally, its low NOx emissions technology meets strict environmental regulations, making it an environmentally friendly option.

The Raypak 055B also includes an innovative ignition system for enhanced safety and convenience. The direct spark ignition eliminates the need for a standing pilot light, reducing gas consumption and further improving efficiency. The unit's freeze protection feature prevents damage during harsh winter conditions, ensuring that users can rely on it throughout the seasons.

In conclusion, the Raypak 055B stands out as a top choice for pool and spa heating solutions. With its combination of efficiency, durability, and advanced technology, it meets the demands of modern consumers looking for comfort without compromising on performance or sustainability. Whether you need to heat a residential pool or a commercial spa, the Raypak 055B is engineered to deliver exceptional results.