AFTER START-UP

Feel the inlet and outlet pipes. Outlet pipe should be only slightly warmer than the inlet. It should not be hot.

WARNING: Should overheating occur or the gas sup- ply fail to shut off, turn off the manual gas control valve to the appliance.

VISUAL INSPECTION

With the heater on, remove the door and make a visual check of the pilot and burner.

The flame should be blue with a well-defined pattern.

4" MAX

Fig. # 8144.0

MAIN BURNER FLAME

PILOT BURNER FLAME

A yellow or "floating" flame indicates restricted air openings or incorrect orifice size. Should this occur, shut the heater off and contact your installer or gas supplier.

WATER PRESSURE SWITCH

A water pressure switch is provided in the heater to shut off the burners in the event that water supply to the heater is interrupted. It is very important to verify that the switch electrically opens and shuts off the gas valve when water flow to the heater is interrupted. Otherwise, rapid and severe damage will likely occur to the heater. (The water pressure switch should be checked and adjusted for proper operation by a quali- fied service person at the time of installation and periodically checked thereafter. Refer to pressure switch servicing instruction in Section 4 of this manual.)

WARNING: Operation of the heater without water circulation will cause rapid and severe damage to the heater.

SECTION 2 / CAUTION

Elevated water temperature can be hazardous, and the U.S. Consumer Product Safety Commission recommends the following guidelines:

1.Spa or hot tub water temperatures should never exceed 104°F (40°C). A temperature of 100°F (38°C) is considered safe for a healthy adult. Special caution is suggested for young children.

2.Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subse- quently result in drowning.

3.Pregnant women beware! Soaking in water over 102° F (39°C) can cause fetal damage during the first three months of pregnancy, (resulting in the birth of a brain damaged or deformed child). Pregnant women should stick to the 100°F (38°C) maximum rule.

4.Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; spa or hot tub thermostats may err in regulating water temperatures by as much as four degrees Fahrenheit (2.2°C).

5.Persons with a medical history of heart disease, circulatory problems, diabetes, or blood pres sure problems should obtain a physician's advice before using pools or hot tubs.

6.Persons taking medications which induce drowsiness, such as tranquilizers, antihista mines, or anticoagulants, should not use spas or hot tubs.

SECTION 3 / MAINTENANCE

AND CARE PROCEDURES

To be followed one month after start-up and then semi-annually.

1.Inspect top of heater and draft hood for soot, (a sticky black substance around finned tubes, baffle and open flue gas passageways).

CAUTION: Soot may be combustible. Wet sooted surfaces completely prior to cleaning. Do not use steel wire brush.

2.Clean main burners and pilot burner of dust and lint.

3.Inspect and operate all controls, gas valve and pressure relief valve.

5

Image 6
Contents Versa What to do if YOU Smell GASContents Before START-UP Burners For Your Safety Read Before OperatingSTART-UP Procedures WaterMillivolt System Lighting InstructionsTo Turn OFF GAS to Appliance Electronic Ignition Systems Operating InstructionsAfter START-UP Maintenance Care ProceduresWater Pressure Switch Visual InspectionCold Weather Operation Basic Tips if Heater will not FirePool & SPA Water Chemistry Winterizing the SPA HeaterGeneral Specification Installation InstructionsReceiving Equipment ALL Heaters Outdoor HeatersIndoor Heaters Venting ConnectionsStep Vent Piping GAS Pressure Regulator GAS Supply ConnectionsModel Robertshaw MVCompanion Flange Connections Plumbing for Water Connections LocationFlow Rates Automatic Chlorinators and Chemical FeedersElectrical Wiring Millivolt System Auxiliary Bypass Valve AdjustmentPressure Relief Valve Installation Electronic Intermittent Ignition Device System IIDWiring Diagram KEY Fig. #9240Wiring Diagram Millivolt Units With Mechanical Thermostat Wiring Diagram Millivolt Units With Solid State ThermostatWiring Diagram 152178 Model 055 IID Pressure Switch CONTROLS/ADJUSTMENTS/REPLACEMENTSTemperature Controls Servicing InstructionsTWO Speed Pumps Pressure Switch Adjustment Flame ROLL-OUT Safety SwitchHigh Limits High Limit RemovalGAS Valve Removal Pilot Removal and CleaningBurner Drawer Removal Main Burner and Orifice RemovalCombustion Chamber Removal Desooting ProcedureUnitherm Governor U.G. Replacement Control Immersion Well ReplaceTrouble Shooting Guide Liming Bypassing too much water Electrical Solid State Thermostat Millivolt Measured and Estimated Resistance Match Within 20 PercentTroubleshooting Honeywell S8600 Electrical Electronic Ignition IIDHigh Voltage Electrical Solid State Thermostat IID Voltage Between 21.5-28.5Replacement Parts List RAYPAK, INC Agoura Road Westlake VILLAGE, CAIID 13-P 14-P 15-PPage Page Warranty Conditions

055B specifications

The Raypak 055B is a high-performance pool and spa heater recognized for its efficiency, reliability, and advanced technologies tailored to meet the needs of consumers. Its compact design and powerful heating capabilities ensure that users enjoy warm water conditions regardless of the outdoor temperature.

One of the main features of the Raypak 055B is its exceptional heating output. With a power rating that can efficiently heat both pools and spas, this model is designed for performance. The heater's efficient heat exchanger is constructed from copper that enhances the transfer of heat, allowing for rapid heating while optimizing energy use. This results in lower utility bills and a smaller environmental footprint.

The Raypak 055B incorporates innovative technology that enhances user experience. It features a digital display that allows for precise temperature control and easy adjustments. Users can set the desired temperature and monitor energy usage, ensuring they achieve the perfect balance between comfort and efficiency. The built-in diagnostic system helps users troubleshoot any issues quickly, maintaining the heater's performance and prolonging its lifespan.

Another significant characteristic of the Raypak 055B is its reliability. The heater is designed with a durable, rust-resistant cabinet that protects the internal components from the elements. This rugged construction makes the Raypak 055B an excellent choice for outdoor installations, ensuring longevity and reliable operation year-round.

The advanced airflow design in the Raypak 055B ensures a safe and efficient operation. The heater is equipped with a standard fan that aids in efficient operation while minimizing noise. Additionally, its low NOx emissions technology meets strict environmental regulations, making it an environmentally friendly option.

The Raypak 055B also includes an innovative ignition system for enhanced safety and convenience. The direct spark ignition eliminates the need for a standing pilot light, reducing gas consumption and further improving efficiency. The unit's freeze protection feature prevents damage during harsh winter conditions, ensuring that users can rely on it throughout the seasons.

In conclusion, the Raypak 055B stands out as a top choice for pool and spa heating solutions. With its combination of efficiency, durability, and advanced technology, it meets the demands of modern consumers looking for comfort without compromising on performance or sustainability. Whether you need to heat a residential pool or a commercial spa, the Raypak 055B is engineered to deliver exceptional results.