PART 2 - INSTALLATION / SERVICE INSTRUCTIONS

SECTION 1 / RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged, report the damage to the carrier immediately.

On occasion, we ship some items loose. Be sure that you receive the number of packages indicated on the Bill of Lading.

When ordering parts, you must specify model and serial number of heater. When ordering under warranty conditions, you must also specify date of installation.

Raypak recommends that this manual be reviewed thoroughly before installing your Raypak pool/spa heater. If there are any questions that this manual does not answer, please contact the factory or your local Raypak representative.

SECTION 2/GENERAL SPECIFICATION

These heaters are design certified and tested under the requirements of ANSI Z21.56/CSA 4.7 American National Standard / CSA standards for gas-fired pool heaters

The heater is interchangeable and can be used either indoor or outdoors. The appropriate top designated for that type of use is required. If desired, the top can be changed at a later date to change from outdoor to indoor or vice versa. Millivolt heaters contain a self-generating electrical system operating between .25 and .75 volts.

AMBIENTTEMPERATURERATINGOFHEATERCOM- PONENTS

Millivolt Heater with Honeywell Gas Valve +32°F to+175°F

Millivolt Heater with Robertshaw Gas Valve 0°F to +175°F

Electronic Ignition Heaters* -32°F to +175°F

*Requires 120V or 240V power supply

Rated inputs suitable for up to 2000 feet elevation. For elevations above 2000 feet, reduce input 4% for each 1000 feet above sea level, as high elevation reduces combustion performance. For Canada, reduce input 10% when installed at 2000-4500 foot elevation.

SECTION 3 / INSTALLATION

INSTRUCTIONS

IMPORTANT NOTICE

These instructions are intended for the use of qualified personnel only, specifically trained and expe- rienced in the installation of this type of heating equip- ment and related system components. Installation and service personnel may be required by some states to be licensed. If your state is such, be sure your contractor bears the appropriate license. Persons not qualified shall not attempt to fix this equipment nor attempt repairs according to these instructions.

WARNING: Improper installation, adjustment, altera- tion, service or maintenance may damage the equip- ment, create a hazard resulting in asphyxiation, explo- sion or fire, and will void the warranty.

CODE REQUIREMENTS

NOTE: The heater should not be located in an area where possible water leakage will result in damage to the area adjacent to the appliance or to the structure. When such locations cannot be avoided, it is recom- mended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.

Installation must be in accordance with local codes, or, in the absence of local codes, with the latest editions of the National Fuel Gas Code, ANSI Z223.1, and the National Electrical Code, ANSI/NFPA 70. For Canada, the latest edition of CAN/CGA B-149.1 and B-149.2

BASE INSTALLATION

Heater must be mounted on a level surface. It can be installed on combustible flooring. Heaters may not be installed on carpeting.

CLEARANCES

WARNING: The heater shall not be located in an area where water sprinklers, or other devices, may cause water to spray through the cabinet louvers and into the heater. This could cause heavy internal rusting or damage some electrical components and this would void the warranty.

7

Image 8
Contents Versa What to do if YOU Smell GASContents For Your Safety Read Before Operating START-UP ProceduresBefore START-UP Burners WaterTo Turn OFF GAS to Appliance Millivolt SystemLighting Instructions Electronic Ignition Systems Operating InstructionsMaintenance Care Procedures Water Pressure SwitchAfter START-UP Visual InspectionBasic Tips if Heater will not Fire Pool & SPA Water ChemistryCold Weather Operation Winterizing the SPA HeaterReceiving Equipment General SpecificationInstallation Instructions ALL Heaters Outdoor HeatersStep Indoor HeatersVenting Connections Vent Piping GAS Supply Connections ModelGAS Pressure Regulator Robertshaw MVPlumbing for Water Connections Location Flow RatesCompanion Flange Connections Automatic Chlorinators and Chemical FeedersAuxiliary Bypass Valve Adjustment Pressure Relief Valve InstallationElectrical Wiring Millivolt System Electronic Intermittent Ignition Device System IIDWiring Diagram KEY Fig. #9240Wiring Diagram Millivolt Units With Mechanical Thermostat Wiring Diagram Millivolt Units With Solid State ThermostatWiring Diagram 152178 Model 055 IID CONTROLS/ADJUSTMENTS/REPLACEMENTS Temperature ControlsPressure Switch Servicing InstructionsPressure Switch Adjustment Flame ROLL-OUT Safety Switch High LimitsTWO Speed Pumps High Limit RemovalPilot Removal and Cleaning Burner Drawer RemovalGAS Valve Removal Main Burner and Orifice RemovalDesooting Procedure Unitherm Governor U.G. ReplacementCombustion Chamber Removal Control Immersion Well ReplaceTrouble Shooting Guide Liming Bypassing too much water Electrical Solid State Thermostat Millivolt Measured and Estimated Resistance Match Within 20 PercentHigh Voltage Troubleshooting Honeywell S8600Electrical Electronic Ignition IID Electrical Solid State Thermostat IID Voltage Between 21.5-28.5Replacement Parts List RAYPAK, INC Agoura Road Westlake VILLAGE, CAIID 13-P 14-P 15-PPage Page Warranty Conditions

055B specifications

The Raypak 055B is a high-performance pool and spa heater recognized for its efficiency, reliability, and advanced technologies tailored to meet the needs of consumers. Its compact design and powerful heating capabilities ensure that users enjoy warm water conditions regardless of the outdoor temperature.

One of the main features of the Raypak 055B is its exceptional heating output. With a power rating that can efficiently heat both pools and spas, this model is designed for performance. The heater's efficient heat exchanger is constructed from copper that enhances the transfer of heat, allowing for rapid heating while optimizing energy use. This results in lower utility bills and a smaller environmental footprint.

The Raypak 055B incorporates innovative technology that enhances user experience. It features a digital display that allows for precise temperature control and easy adjustments. Users can set the desired temperature and monitor energy usage, ensuring they achieve the perfect balance between comfort and efficiency. The built-in diagnostic system helps users troubleshoot any issues quickly, maintaining the heater's performance and prolonging its lifespan.

Another significant characteristic of the Raypak 055B is its reliability. The heater is designed with a durable, rust-resistant cabinet that protects the internal components from the elements. This rugged construction makes the Raypak 055B an excellent choice for outdoor installations, ensuring longevity and reliable operation year-round.

The advanced airflow design in the Raypak 055B ensures a safe and efficient operation. The heater is equipped with a standard fan that aids in efficient operation while minimizing noise. Additionally, its low NOx emissions technology meets strict environmental regulations, making it an environmentally friendly option.

The Raypak 055B also includes an innovative ignition system for enhanced safety and convenience. The direct spark ignition eliminates the need for a standing pilot light, reducing gas consumption and further improving efficiency. The unit's freeze protection feature prevents damage during harsh winter conditions, ensuring that users can rely on it throughout the seasons.

In conclusion, the Raypak 055B stands out as a top choice for pool and spa heating solutions. With its combination of efficiency, durability, and advanced technology, it meets the demands of modern consumers looking for comfort without compromising on performance or sustainability. Whether you need to heat a residential pool or a commercial spa, the Raypak 055B is engineered to deliver exceptional results.