QUICK START GUIDE – SYSTEM SETUP
Presets
The following presets are reserved for special functions.
Preset Function
33Flip command
34Pan zero command
94Reserved
95Select main programming menu
96Stop a scan
97Random scanning
98Frame scanning
99Start auto scanning
NOTE: For American Dynamics controllers with only 32 presets, switch
99 becomes 32 | 92 becomes 25 |
98 becomes 31 | 91 becomes 24 |
97 becomes 30 | 90 becomes 23 |
96 becomes 29 | 89 becomes 22 |
95 becomes 28 | 88 becomes 21 |
93 becomes 26 |
|
If the limit stops are turned off, presets
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<TITLE TEXT> <ALERT>** <CLEAR> <PASSWORD>
BACK
EXIT
| SPECTRA III |
|
|
| LANGUAGE | ENGLISH | |
| <SYSTEM INFORMATION> |
|
|
| <DISPLAY SETUP> |
|
|
| <DOME SETTINGS> |
|
|
| ACK ALERT** |
|
|
| RESET CAMERA |
|
|
| CYCLE CAMERA POWER |
|
|
| REBOOT SYSTEM |
|
|
| EXIT |
|
|
| DISPLAY SETUP |
|
|
PRESET LABEL | (2 SECS) | ||
ZONE LABEL | (2 SECS) | ||
ZOOM | (2 SECS) | ||
AZIMUTH/ELEVATION | (2 SECS) | ||
DIRECTION | OFF | ||
ALARM MESSAGE | (2 SECS) |
<LABEL POSTIONS> RESTORE FACTORY DEFAULTS
BACK
EXIT
LABEL POSITION
[ZONE
[PRESET
[ALERT
[TITLE TEXT]
SAVE AND EXIT
CANCEL AND EXIT
HELP
NE
XXX.XXX
SYSTEM INFORMATION
DOME DRIVE MODEL |
| DD53TC16 | ||
BACK BOX MEMORY |
| AVAILABLE | ||
SOFTWARE VERSION |
| XX.X | ||
BIOS VERSION |
| XX.X | ||
FONT VERSION |
| XX.X | ||
COMM |
| 2400, N, 8, 1 | ||
D ADDRESS |
| 1 | ||
P ADDRESS |
| 2 | ||
CM9500 MODE |
| OFF | ||
32 PRESETS |
| OFF | ||
PROTOCOL |
| C | ||
PRESSURIZED** |
| X.XX | ||
<ADDITIONAL> |
|
|
| |
BACK |
|
|
| |
EXIT |
|
|
| |
|
|
| ||
|
|
|
| |
ADDITIONAL |
|
| ||
FREE MEMORY |
| 18304 |
| |
LAST RESET |
| POWER ON | ||
AZIMUTH ZERO OFFSET | 0O | |||
MOTOR ACTIVE |
| YES | ||
CAMERA ACTIVE |
| YES | ||
FPGA VERSION |
| X | ||
VIDEO LEVEL |
| NORMAL | ||
CAMERA |
| |||
LANGUAGE 1 | ENGLISH X.XX | |||
LANGUAGE 6 | ITALIANO X.XX | |||
BACK |
|
|
| |
EXIT |
|
|
|
Quick Programming Guide
Access main menu (preset 95). See the Accessing Main Menu (Preset 95) section.
Use the joystick* to position the cursor beside menu selection.
Press Iris Open, the submenu/cursor moves to the right.
Move the joystick up or down to view selections.
Press Iris Open to make selection.
Press Iris Close to cancel selection.
CAMERA |
|
| MOTION |
|
| POWER UP |
| LINE SYNC |
|
| PRESETS |
|
| PATTERNS |
|
|
AUTO FOCUS | ON | AUTO FLIP | ON | POWER UP ACTION AUTO |
| LINE SYNC | ON PRESET NUMBER | 1 PATTERN NUMBER | 1 |
| ||||||
ZOOM LIMIT | X128 | PROPORTIONAL PAN | ON |
|
|
| LINE SYNC PHASE | 0 * * * PRESET NOT DEFINED * * * |
|
| <PROGRAM PATTERN> |
|
| |||
ZOOM SPEED | MEDIUM | PARK TIME (MINUTES) | 0 |
|
|
|
|
| <EDIT PRESET LABEL> |
|
| <CLEAR PATTERN> |
|
| ||
LOW LIGHT LIMIT | 2 | PARK ACTION | NONE | BACK |
| BACK |
| <EDIT PRESET SCENE> |
|
| BACK |
|
| |||
|
|
| SCAN SPEED DEG/S | 25 |
|
| <CLEAR PRESET> |
|
|
|
| |||||
<ADVANCED SETTINGS> |
|
| LIMIT STOPS | ON | EXIT |
| EXIT |
|
|
| EXIT |
|
| |||
|
|
|
|
|
|
|
| BACK |
|
| REFERENCE INFORMATION | |||||
BACK |
|
| <SET MANUAL STOPS> |
|
|
|
|
|
| EXIT |
|
| ||||
|
| <CLEAR MANUAL STOPS> |
|
|
|
|
|
|
|
| PATTERN USAGE | 0% |
| |||
EXIT |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| <SET SCAN STOPS> |
|
|
|
|
|
| REFERENCE INFORMATION |
|
| REMAINING | 100% |
| |
|
|
| <CLEAR SCAN STOPS> |
|
|
|
|
|
| - |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| AZIMUTH |
|
|
|
| ||
|
|
| <SET AZIMUTH ZERO> |
|
|
|
|
|
|
| ELEVATION | - |
|
|
|
|
|
|
| <CLEAR AZIMUTH ZERO> |
|
|
|
|
|
|
| ZOOM | - |
|
|
|
|
|
|
| BACK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EXIT |
|
|
|
|
|
|
|
|
|
|
|
|
|
ADVANCED SETTINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SHUTTER SPEED | AUTO |
|
|
| * If your controller does not have a joystick, use the up or down key. |
|
| |||||||||
AGC LIMIT | 25 |
|
|
|
|
| ||||||||||
AUTO IRIS | AUTO |
|
|
| ** This setting only applies to Pressurized Spectra III dome systems with software version | |||||||||||
AUTO IRIS LEVEL | 66 |
|
|
| ||||||||||||
AUTO IRIS PEAK | 8 |
|
|
| 1.25 or higher. Spectra III systems that are not pressurized or pressurized systems that do | |||||||||||
AUTO SHARPNESS | ON |
|
|
| ||||||||||||
SHARPNESS LEVEL | 26 |
|
|
| not have dome drive software version 1.25 or higher will not display this menu item. |
|
| |||||||||
AUTO WHITE BALANCE | ON |
|
|
|
|
| ||||||||||
R GAIN | 482 |
|
|
| Software version 1.25 or higher includes the software to monitor temperature, pressure, | |||||||||||
B GAIN | 678 |
|
|
| ||||||||||||
BACKLIGHT COMP | OFF |
|
|
| and dew point for Pressurized Spectra III systems. |
|
|
|
|
| ||||||
VIDEO LEVEL | HIGH |
|
|
|
|
|
|
|
|
BACK
EXIT
ZONES |
|
| TITLE TEXT |
ZONE NUMBER | 1 |
| ENABLE TITLE TEXT |
* * * ZONE NOT DEFINED * * * |
|
| <EDIT TITLE TEXT> |
<EDIT ZONE LABEL> |
|
|
|
<EDIT ZONE> | NO |
|
|
ZONE ENABLED |
| BACK | |
ZONE BLANKING | OFF |
| EXIT |
<CLEAR ZONE> |
|
|
|
BACK |
|
|
|
EXIT |
|
|
|
ALERT** |
|
| CLEAR |
| PASSWORD |
|
REPEAT | CONSTANT |
| RESTORE FACTORY DEFAULTS | ENABLE PASSWORD | OFF | |
ACK ACTION | ALWAYS ON |
|
| <EDIT PASSWORD> |
| |
ACTIVATE AUX | NO |
| BACK |
|
|
|
<CURRENT READING> |
|
| EXIT | BACK |
| |
RESET ALERT |
|
|
|
| ||
BACK |
|
|
| EXIT |
| |
|
|
|
|
|
| |
EXIT |
|
|
|
|
|
|
CURRENT READING** | EDIT THE PASSWORD |
| |
TEMPERATURE | 0°C |
| |
|
| ||
| 0°F | 1234567890 | OK |
DEWPOINT | 0°C | ABCDEFGHIJ | CANCEL |
| 0°F | KLMNOPQRST |
|
PRESSURE | 0.0 PSIG | SPACE | |
| 0.0 BAR | abcdefghij | BACKSPACE |
REFRESH |
| klmnopqrst |
|
BACK |
| uvwxyz#&:* |
|
|
|
| |
EXIT |
|
|
|
11 |