Alert
SPECTRA III
LANGUAGEENGLISH
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
NOTE: The Alert section only applies to Pressurized Spectra III dome systems with software version 1.25 or higher. Spectra III systems that are not pressurized or pressurized systems that do not have dome drive software version 1.25 or higher will not display this menu item. Software version 1.25 or higher includes the software to monitor temperature, pressure, and dew point for Pressurized Spectra III systems.
Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point. If internal conditions reach unacceptable levels, an alert message appears on the screen describing the alert condition. Example: If pressure drops below 1 psig, “LOW PRESSURE” is displayed on the monitor.
The following system conditions will trigger an alert message:
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<TITLE TEXT> <ALERT> <CLEAR> <PASSWORD>
BACK
EXIT
ALERT |
|
|
|
REPEAT | CONSTANT |
ACK ACTION | ALWAYS ON |
ACTIVATE AUX | NO |
<CURRENT READING> |
|
RESET ALERT |
|
BACK |
|
EXIT |
|
System Condition | Alert Message |
Temperature is above 140°F (60°C) | HIGH TEMPERATURE |
Temperature is below | LOW TEMPERATURE |
Pressure is above 11 PSIG | HIGH PRESSURE |
Pressure is below 1 PSIG | LOW PRESSURE |
The difference between the temperature and the | DEW POINT (HIGH HUMIDITY) |
dew point is less than or equal to 3°C. |
|
|
|
The alert message will be repeatedly displayed until the system controller acknowledges the alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message changes to the programmed acknowledge action (ACK ACTION). If the alert condition remains active after a period of time, the alert message reappears on the monitor, restarting the alert message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system controller acknowledges the alert condition. The following are the settings for REPEAT:
CONSTANTThe alert message is continuously displayed on the monitor until acknowledged.
15 MIN | The alert message is displayed every 15 minutes for a |
| duration until acknowledged. |
30 MIN | The alert message is displayed every 30 minutes for a |
| duration until acknowledged. |
60 MIN | The alert message is displayed every 60 minutes for a |
| duration until acknowledged. |
32 |
|