Stovax 8455 manual Installation Instructions, 16” AND REDUCED DRAUGHT COAL LAYOUT

Page 15
NOTE: CERAMIC PARTS ARE FRAGILE.

INSTALLATION INSTRUCTIONS

INSTALLATION

NOTE: CERAMIC PARTS ARE FRAGILE.

6.1Position the flame baffle on the rear of the tray. See Diagram 13 arrow B.

6.2Position the front coal, make sure it sits flat onto the burner skin. See Diagram 13 arrow C.

13

AR2190

6.3Place the coals following the appropriate Diagrams and Instructions:

16” AND REDUCED DRAUGHT COAL LAYOUT

6.4Curved fronts (Holyrood and Richmond)-place 5 large coals onto the front coal moulding ensuing that they rest against the front Place 2 small coals on to the front coal, 1 at each end.

See Diagram 14.

14

AR1115

6.5Flat fronts (All others) - Place 3 large coals and 4 small coals onto the front coal moulding ensuring that they rest against the decorative front, these should run intermittently small, large, small etc. See Diagram 15.

15

AR1116

6.6Place 5 large coals onto the flame baffle fingers. See Diagram 16.

16

AR1117

6.7Place 4 large coals so that they form a bridge between the other 2 rows, and 2 small coals, 1 at each end. Place 4 large coals at the back of the fire. See Diagram 17.

17

AR1118

6.8Place the remaining 4 small coals on top of the others so that they form a bridge between the second and third rows. See Diagram 18.

18

AR1119

15

Image 15
Contents VFC Radiant & Convector Fire Range For use in GB, IE Great Britain and EireInstructions for Use Installation and Servicing With upgradeable control valveCONTENTS user instructions instaLlation InstructionsServicing Instructions APPLIANCE COMMISSIONING CHECKLIST DEALER AND INSTALLER INFORMATIONIMPORTaNT NOTICE 3.TURNING THE FIRE OFF USER INSTRUCTIONS1.general 2.LIGHTING THE FIRE7.ARRANGEMENT OF FUEL BED COMPONENTS 6.CLEANING THE FIREUSER INSTRUCTIONS 5.UPGRADING YOUR FIREUSER INSTRUCTIONS 16” AND REDUCED DRAUGHT COAL LAYOUT18” COAL LAYOUT AR1122 USER INSTRUCTIONS22” COAL LAYOUT AR11219. THE FLAME FAILURE DEVICE 13. INSTALLATION DETAILSUSER INSTRUCTIONS 8. OXYGEN DEPLETION SENSORVFC CONVECTOR TECHNICAL SPECIFICATIONtHESE INSTRUCTIONS COVER THE FOLLOWING MODELS VFC RADIANTSITE REQUIREMENTS INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS SITE REQUIREMENTS1A VFC Radiant 1B VFC Convector 2.SAFETY PRECAUTIONS INSTALLATIONINSTALLATION INSTRUCTIONS 1.CONTROL UPGRADEINSTALLATION INSTRUCTIONS INSTALLATION5.INSTALLATION - CONVECTOR FIRES 6.ARRANGEMENT OF FUELBED COMPONENTS INSTALLATION INSTRUCTIONSINSTALLATION ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICSNOTE CERAMIC PARTS ARE FRAGILE INSTALLATION INSTRUCTIONSINSTALLATION 16” AND REDUCED DRAUGHT COAL LAYOUT18” COAL LAYOUT INSTALLATION INSTRUCTIONSINSTALLATION 6.9Curved fronts Holyrood- Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See DiagramINSTALLATION INSTRUCTIONS INSTALLATION7.LIGHTING COMMISSIONING INSTALLATION INSTRUCTIONS1.COMMISSIONING SERVICING REQUIREMENTS SERVICING INSTRUCTIONSIGNITION FUNCTIONAL CHECK NO SPARK FAULT FINDINGSee “NO SPARK” chart IGNITION FUNCTIONAL CHECK PILOT WILL NOT LIGHT3.PIEZO REPLACING PARTSSERVICING INSTRUCTIONS 2.IGNITION LEAD6.GAS VALVE REPLACING PARTSSERVICING INSTRUCTIONS 5. ODS PILOT UNIT8.MAIN INJECTOR INSTALLATION INSTRUCTIONSREPLACING PARTS 7.MAG UNITSPARES PARTS LIST MANUAL FIRESNatural Gas Parts SERVICE RECORDS