Section 2.

INSTALLATION INSTRUCTIONS

REPLACING PARTS

6.4To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in Diagram 10, lever it gently and pull from the right hand side at the same time. The cover will now come off, there is a small cylindrical metal spacer inside the cover. This must be kept and replaced on the fixing screw during re-assembly.

10

AR0916

6.5Disconnect the ignition lead from the gas valve, refer to

Section 2.

6.6Undo the two bolts securing the gas valve to the appliance and remove the valve.

6.7Replace in reverse order.

6.8Check all joints for gas leaks, check operation of the thermocouple and ignition lead.

7.MAG UNIT

7.1Carry out operations (a) to (d), Section 4.

7.2Undo the mag unit retaining nut at the back of the control valve. See Diagram 11 arrow A.

11

AR0945

7.3After removing the retaining nut, the mag unit can be tapped out and a replacement fitted.

7.4Replace the mag unit retaining nut and tighten. Note - this is a gas-tight seal.

7.5Replace the thermocouple and check for gas leaks.

7.6After reassembly, carry out the flame failure functional check as detailed in the flow chart, especially the mag unit drop out time.

8.MAIN INJECTOR

8.1Carry out operations (a) to (d), Section 4.

8.2With the fire removed, undo the injector compression nut (see Diagram 12 arrow C), pull the pipe clear of the injector body.

12

AR0945

8.3Rotate the injector until it is fully removed.

8.4Replace with the correct replacement injector. When ordering, always state the model, gas type and serial number.

8.5Reassemble and turn the gas supply on, check for any leaks.

9. CHANGING BETWEEN GAS TYPES

The following parts must be changed when converting an appliance from one gas type to another:

Main injector

Pilot assembly

Aeration adjuster

Control valve

Data Badge

Refer to Gazco for a Conversion Kit

Note: The control valve will be set for the particular Appliance. In addition a new databadge will need to be ordered. In all instances, when ordering new parts, be sure to quote the appliance type and serial number.

Use only genuine Gazco replacement parts. Non-standard components will invalidate the guarantee and may be dangerous.

23

Image 23
Contents VFC Radiant & Convector Fire Range For use in GB, IE Great Britain and EireInstructions for Use Installation and Servicing With upgradeable control valveServicing Instructions CONTENTSuser instructions instaLlation Instructions IMPORTaNT NOTICE APPLIANCE COMMISSIONING CHECKLISTDEALER AND INSTALLER INFORMATION 3.TURNING THE FIRE OFF USER INSTRUCTIONS1.general 2.LIGHTING THE FIRE7.ARRANGEMENT OF FUEL BED COMPONENTS 6.CLEANING THE FIREUSER INSTRUCTIONS 5.UPGRADING YOUR FIRE18” COAL LAYOUT USER INSTRUCTIONS16” AND REDUCED DRAUGHT COAL LAYOUT AR1122 USER INSTRUCTIONS22” COAL LAYOUT AR11219. THE FLAME FAILURE DEVICE 13. INSTALLATION DETAILSUSER INSTRUCTIONS 8. OXYGEN DEPLETION SENSORVFC CONVECTOR TECHNICAL SPECIFICATIONtHESE INSTRUCTIONS COVER THE FOLLOWING MODELS VFC RADIANTSITE REQUIREMENTS INSTALLATION INSTRUCTIONS1A VFC Radiant 1B VFC Convector INSTALLATION INSTRUCTIONSSITE REQUIREMENTS 2.SAFETY PRECAUTIONS INSTALLATIONINSTALLATION INSTRUCTIONS 1.CONTROL UPGRADE5.INSTALLATION - CONVECTOR FIRES INSTALLATION INSTRUCTIONSINSTALLATION 6.ARRANGEMENT OF FUELBED COMPONENTS INSTALLATION INSTRUCTIONSINSTALLATION ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICSNOTE CERAMIC PARTS ARE FRAGILE INSTALLATION INSTRUCTIONSINSTALLATION 16” AND REDUCED DRAUGHT COAL LAYOUT18” COAL LAYOUT INSTALLATION INSTRUCTIONSINSTALLATION 6.9Curved fronts Holyrood- Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram7.LIGHTING INSTALLATION INSTRUCTIONSINSTALLATION 1.COMMISSIONING COMMISSIONINGINSTALLATION INSTRUCTIONS SERVICING REQUIREMENTS SERVICING INSTRUCTIONSIGNITION FUNCTIONAL CHECK NO SPARK FAULT FINDINGSee “NO SPARK” chart IGNITION FUNCTIONAL CHECK PILOT WILL NOT LIGHT3.PIEZO REPLACING PARTSSERVICING INSTRUCTIONS 2.IGNITION LEAD6.GAS VALVE REPLACING PARTSSERVICING INSTRUCTIONS 5. ODS PILOT UNIT8.MAIN INJECTOR INSTALLATION INSTRUCTIONSREPLACING PARTS 7.MAG UNITNatural Gas Parts SPARES PARTS LISTMANUAL FIRES SERVICE RECORDS