5. ODS PILOT UNIT

SERVICING INSTRUCTIONS

REPLACING PARTS

5. ODS PILOT UNIT

Note: The pilot unit on the appliance is a non serviceable unit due to the complex nature of its manufacture. Replacement of the complete unit must be carried out if one of the following items becomes faulty:

Pilot injector Ignition electrode Thermocouple

5.1Carry out operations (a) to (d), Section 4.

5.2Gently pull the ignition lead off the electrode. See Diagram 5 arrow A.

5

AR0305

5.3Remove the two screws securing the pilot assembly. See Diagram 5 arrow B.

5.4Undo the thermocouple connection at the back of the gas valve. See Diagram 6 arrow A.

6

AR0945

5.5Replace with a new pilot assembly. Set the spark gap. See Diagram 7.

7

AR0097

5.6After reassembly, check for gas soundness and carry out a flame failure functional check details in the flow chart, especially the mag drop out time.

6.GAS VALVE

6.1Turn the gas supply off at the isolation device.

6.2Disconnect the 2x8mm and 1x4mm gas pipe fittings at the back of the gas valve and also disconnect the thermocouple, see Diagram 8 arrow B.

8

AR0945

6.3Undo the single screw that secures the left hand side of the control cover, see Diagram 9.

9

AR0915

22

Image 22
Contents With upgradeable control valve For use in GB, IE Great Britain and EireInstructions for Use Installation and Servicing VFC Radiant & Convector Fire Rangeuser instructions instaLlation Instructions CONTENTSServicing Instructions DEALER AND INSTALLER INFORMATION APPLIANCE COMMISSIONING CHECKLISTIMPORTaNT NOTICE 2.LIGHTING THE FIRE USER INSTRUCTIONS1.general 3.TURNING THE FIRE OFF5.UPGRADING YOUR FIRE 6.CLEANING THE FIREUSER INSTRUCTIONS 7.ARRANGEMENT OF FUEL BED COMPONENTS16” AND REDUCED DRAUGHT COAL LAYOUT USER INSTRUCTIONS18” COAL LAYOUT AR1121 USER INSTRUCTIONS22” COAL LAYOUT AR11228. OXYGEN DEPLETION SENSOR 13. INSTALLATION DETAILSUSER INSTRUCTIONS 9. THE FLAME FAILURE DEVICEVFC RADIANT TECHNICAL SPECIFICATIONtHESE INSTRUCTIONS COVER THE FOLLOWING MODELS VFC CONVECTORINSTALLATION INSTRUCTIONS SITE REQUIREMENTSSITE REQUIREMENTS INSTALLATION INSTRUCTIONS1A VFC Radiant 1B VFC Convector 1.CONTROL UPGRADE INSTALLATIONINSTALLATION INSTRUCTIONS 2.SAFETY PRECAUTIONSINSTALLATION INSTALLATION INSTRUCTIONS5.INSTALLATION - CONVECTOR FIRES ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS INSTALLATION INSTRUCTIONSINSTALLATION 6.ARRANGEMENT OF FUELBED COMPONENTS16” AND REDUCED DRAUGHT COAL LAYOUT INSTALLATION INSTRUCTIONSINSTALLATION NOTE CERAMIC PARTS ARE FRAGILE6.9Curved fronts Holyrood- Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram INSTALLATION INSTRUCTIONSINSTALLATION 18” COAL LAYOUTINSTALLATION INSTALLATION INSTRUCTIONS7.LIGHTING INSTALLATION INSTRUCTIONS COMMISSIONING1.COMMISSIONING SERVICING INSTRUCTIONS SERVICING REQUIREMENTSIGNITION FUNCTIONAL CHECK PILOT WILL NOT LIGHT FAULT FINDINGSee “NO SPARK” chart IGNITION FUNCTIONAL CHECK NO SPARK2.IGNITION LEAD REPLACING PARTSSERVICING INSTRUCTIONS 3.PIEZO5. ODS PILOT UNIT REPLACING PARTSSERVICING INSTRUCTIONS 6.GAS VALVE7.MAG UNIT INSTALLATION INSTRUCTIONSREPLACING PARTS 8.MAIN INJECTORMANUAL FIRES SPARES PARTS LISTNatural Gas Parts SERVICE RECORDS