Stovax 8455 manual Installation Instructions, 18” COAL LAYOUT, 22” COAL LAYOUT

Page 16
6.9Curved fronts (Holyrood) - Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram 19.

INSTALLATION INSTRUCTIONS

INSTALLATION

18” COAL LAYOUT

6.9Curved fronts (Holyrood) - Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram 19.

19

AR1120

6.10Flat fronts (All others) - Place 4 large coals and 4 small coals onto the front coal moulding ensuring that they rest against the decorative front; these should run intermittently small, large, small, with 2 large in the centre. See Diagram 20.

20

AR1121

6.11 Place 6 large coals onto the flame baffle fingers. See Diagram 21.

21

AR1122

6.12Place 5 large coals so that they form a bridge between the other 2 rows, and 2 small coals, 1 at each end. Place 5 large coals at the back of the fire. See Diagram 22.

22

AR1129

6.13Place the remaining 5 small coals on top of the others so that they form a bridge between the second and third rows. See Diagram 23.

23

AR1124

22” COAL LAYOUT

6.14All fronts - place 8 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals on to the front coal, 1 at each end. See Diagram 24.

24

AR1126

6.15Place 8 large coals onto the flame baffle fingers. See Diagram 25.

16

Image 16
Contents For use in GB, IE Great Britain and Eire Instructions for Use Installation and ServicingWith upgradeable control valve VFC Radiant & Convector Fire Rangeuser instructions instaLlation Instructions CONTENTSServicing Instructions DEALER AND INSTALLER INFORMATION APPLIANCE COMMISSIONING CHECKLISTIMPORTaNT NOTICE USER INSTRUCTIONS 1.general2.LIGHTING THE FIRE 3.TURNING THE FIRE OFF6.CLEANING THE FIRE USER INSTRUCTIONS5.UPGRADING YOUR FIRE 7.ARRANGEMENT OF FUEL BED COMPONENTS16” AND REDUCED DRAUGHT COAL LAYOUT USER INSTRUCTIONS18” COAL LAYOUT USER INSTRUCTIONS 22” COAL LAYOUTAR1121 AR112213. INSTALLATION DETAILS USER INSTRUCTIONS8. OXYGEN DEPLETION SENSOR 9. THE FLAME FAILURE DEVICETECHNICAL SPECIFICATION tHESE INSTRUCTIONS COVER THE FOLLOWING MODELSVFC RADIANT VFC CONVECTORINSTALLATION INSTRUCTIONS SITE REQUIREMENTSSITE REQUIREMENTS INSTALLATION INSTRUCTIONS1A VFC Radiant 1B VFC Convector INSTALLATION INSTALLATION INSTRUCTIONS1.CONTROL UPGRADE 2.SAFETY PRECAUTIONSINSTALLATION INSTALLATION INSTRUCTIONS5.INSTALLATION - CONVECTOR FIRES INSTALLATION INSTRUCTIONS INSTALLATIONADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS 6.ARRANGEMENT OF FUELBED COMPONENTSINSTALLATION INSTRUCTIONS INSTALLATION16” AND REDUCED DRAUGHT COAL LAYOUT NOTE CERAMIC PARTS ARE FRAGILEINSTALLATION INSTRUCTIONS INSTALLATION6.9Curved fronts Holyrood- Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram 18” COAL LAYOUTINSTALLATION INSTALLATION INSTRUCTIONS7.LIGHTING INSTALLATION INSTRUCTIONS COMMISSIONING1.COMMISSIONING SERVICING INSTRUCTIONS SERVICING REQUIREMENTSFAULT FINDING See “NO SPARK” chartIGNITION FUNCTIONAL CHECK PILOT WILL NOT LIGHT IGNITION FUNCTIONAL CHECK NO SPARKREPLACING PARTS SERVICING INSTRUCTIONS2.IGNITION LEAD 3.PIEZOREPLACING PARTS SERVICING INSTRUCTIONS5. ODS PILOT UNIT 6.GAS VALVEINSTALLATION INSTRUCTIONS REPLACING PARTS7.MAG UNIT 8.MAIN INJECTORMANUAL FIRES SPARES PARTS LISTNatural Gas Parts SERVICE RECORDS