16” AND REDUCED DRAUGHT COAL LAYOUT

USER INSTRUCTIONS

16” AND REDUCED DRAUGHT COAL LAYOUT

7.4Curved fronts (Holyrood and Richmond) Place 5 large coals onto the front coal moulding ensuing that they rest against the front. Place 2 small coals on to the front coal, 1 at each end.

See Diagram 4.

4

AR1115

7.5 Flat fronts (All others) - Place 3 large coals and 4 small coals onto the front coal moulding ensuring that they rest against the decorative front, these should run intermittently small, large, small etc. See Diagram 5.

5

AR1116

7.6 Place 5 large coals onto the flame baffle fingers. See Diagram 6.

6

AR1117

7.7Place 4 large coals so that they form a bridge between the other 2 rows, and 2 small coals, 1 at each end. Place 4 large coals at the back of the fire. See Diagram 7.

7

AR1118

7.8Place the remaining 4 small coals on top of the others so that they form a bridge between the second and third rows. See Diagram 8.

8

AR1119

18” COAL LAYOUT

7.9Curved fronts (Holyrood) - place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals on to the front coal, 1 at each end. See Diagram 9.

9

AR1120

7.10Flat fronts (All others) - Place 4 large coals and 4 small coals onto the front coal moulding ensuring that they rest against the decorative front, these should run intermittently small, large, small, with 2 large in the centre. See Diagram 10.

6

Image 6
Contents With upgradeable control valve For use in GB, IE Great Britain and EireInstructions for Use Installation and Servicing VFC Radiant & Convector Fire RangeCONTENTS user instructions instaLlation InstructionsServicing Instructions APPLIANCE COMMISSIONING CHECKLIST DEALER AND INSTALLER INFORMATIONIMPORTaNT NOTICE 2.LIGHTING THE FIRE USER INSTRUCTIONS1.general 3.TURNING THE FIRE OFF5.UPGRADING YOUR FIRE 6.CLEANING THE FIREUSER INSTRUCTIONS 7.ARRANGEMENT OF FUEL BED COMPONENTSUSER INSTRUCTIONS 16” AND REDUCED DRAUGHT COAL LAYOUT18” COAL LAYOUT AR1121 USER INSTRUCTIONS22” COAL LAYOUT AR11228. OXYGEN DEPLETION SENSOR 13. INSTALLATION DETAILSUSER INSTRUCTIONS 9. THE FLAME FAILURE DEVICEVFC RADIANT TECHNICAL SPECIFICATIONtHESE INSTRUCTIONS COVER THE FOLLOWING MODELS VFC CONVECTORINSTALLATION INSTRUCTIONS SITE REQUIREMENTSINSTALLATION INSTRUCTIONS SITE REQUIREMENTS1A VFC Radiant 1B VFC Convector 1.CONTROL UPGRADE INSTALLATIONINSTALLATION INSTRUCTIONS 2.SAFETY PRECAUTIONSINSTALLATION INSTRUCTIONS INSTALLATION5.INSTALLATION - CONVECTOR FIRES ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS INSTALLATION INSTRUCTIONSINSTALLATION 6.ARRANGEMENT OF FUELBED COMPONENTS16” AND REDUCED DRAUGHT COAL LAYOUT INSTALLATION INSTRUCTIONSINSTALLATION NOTE CERAMIC PARTS ARE FRAGILE6.9Curved fronts Holyrood- Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end. See Diagram INSTALLATION INSTRUCTIONSINSTALLATION 18” COAL LAYOUTINSTALLATION INSTRUCTIONS INSTALLATION7.LIGHTING COMMISSIONING INSTALLATION INSTRUCTIONS1.COMMISSIONING SERVICING INSTRUCTIONS SERVICING REQUIREMENTSIGNITION FUNCTIONAL CHECK PILOT WILL NOT LIGHT FAULT FINDINGSee “NO SPARK” chart IGNITION FUNCTIONAL CHECK NO SPARK2.IGNITION LEAD REPLACING PARTSSERVICING INSTRUCTIONS 3.PIEZO5. ODS PILOT UNIT REPLACING PARTSSERVICING INSTRUCTIONS 6.GAS VALVE7.MAG UNIT INSTALLATION INSTRUCTIONSREPLACING PARTS 8.MAIN INJECTORSPARES PARTS LIST MANUAL FIRESNatural Gas Parts SERVICE RECORDS