Samsung AQV09PSBX Troubleshooting, Problem, Solution, not work at all, The temperature, working

Page 20
Troubleshooting

Troubleshooting

Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.

PROBLEM

SOLUTION

 

 

 

The air conditioner does

• Check power status and then operate the air conditioner again.

not work at all.

• Plug in or switch on the circuit breaker and then operate the air conditioner again.

 

• Check if you have set the Off Timer. Operate the air conditioner again by pressing the

 

 

Power button.

 

 

 

The temperature

• Check if you have selected Fan/Turbo mode. In these modes, desired temperature is set to

adjustment is not working.

 

auto and you cannot adjust the temperature.

 

 

 

Cool/Warm air does

• Check if the set temperature is higher(during Cool mode)/lower(during Heat mode) than

not come out of the air

 

the current temperature. Press the Temp + or - button on the remote controller to change

conditioner.

 

the set temperature.

 

 

• Check if the Air filter is blocked by dirt. If there is a lot of dust on the Air filter,

 

 

cooling(heating) performance may decrease. Clean them frequently.

 

• Check if the outdoor unit is covered or installed near the obstacle. Take the cover off and

 

 

take the obstacle away.

 

 

• If you want to operate the air conditioner in the sunlight, cover the outdoor unit using

 

 

curtains or etc.

 

 

• Check if the air conditioner is operating in De-ice mode. When the ice formed in winter

 

 

or the outdoor temperature is too low, the air conditioner operates in De-ice mode

 

 

automatically. In De-ice mode, indoor fan stops and cool air does not come out.

 

• If the doors or windows are open, it may cause bad cooling (heating) performance.

 

 

Close the doors and windows.

 

 

• Check if the air conditioner has just been turned on after stopping cooling(heating)

 

 

operation. In this case, just a fan will run to protect the outdoor unit compressor.

 

• Check if the pipe length is too long. When the pipe length exceeds maximum allowable

 

 

pipe length, cooling (heating) performance may decrease.

 

 

 

 

Air flow adjustment is not

Check if you have selected Auto/Dry/

mode. In these modes, desired

working.

 

temperature is set to auto and you cannot adjust the temperature.

 

 

 

 

Fan speed adjustment is

Check if you have selected Auto/Dry/Turbo/

mode. In these mode, fan speed

not working.

 

is set to Auto and you cannot adjust the fan speed.

 

 

 

Remote controller is not

• Check if your batteries are depleted.

 

working.

• Make sure nothing is blocking your remote controller sensor.

Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves.

Timer function does not

• Check if you press the Set button on the remote controller after you have set the time.

set.

 

 

 

 

 

 

 

The indicator is blinking

• Press the Power

 

button or disconnect the power plug/switch off the auxiliary power

 

 

continuously.

switch.

 

If the indicator is still blinking, contact the service center.

 

 

 

 

Odors permeate in the

• Check if the appliance is running in a smoky area. Ventilate the room or operate the air

room during operation.

conditioner in Fan mode for 1~2 hours. (We do not use smelly components in the air

 

conditioner.)

20

Image 20 Contents
Page Features of your new air conditioner Cool Summer OfferCost Efficient System Look for EverywhereSafety precautions USING PARTSImportant safety symbols and precautions FOR INSTALLATIONFOR USING FOR POWER SUPPLYDo not pull the power cord, when unplugging the power plug Do not touch the power plug or the circuit breaker with wet handsFOR CLEANING Do not clean the inside of the air conditioner by yourselfDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsChecking before use Operation rangesModel RJ Maintaining your air conditionerPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Smart Saver On TimerRemote controller display Battery changing timeStoring the remote controller Turbo indicatorBasic function AutoCool Heatbutton to adjust the temperature Press the button to turn on the air conditionerPress the button to set the operating mode Press theAdjusting the air flow direction Using the Turbo functionPress the Air swingbutton on the remote controller Press the Turbo button on the remote controller during Cool modeWhen the air conditioner is on and in cool/heat mode 1. Press the button on the remote controllermode Temperature and fan speed changes in modeSetting the On/Off timer Setting On timer Setting Off timer1. Press the On Timer/Off Timer button Additional options available in On timer modeUsing the Smart Saver function If the air conditioner is onIf the air conditioner is off Combining On Timer and Off TimerUsing the Quiet function Using the Auto Clean functionPress the Auto Clean button When the air conditioner is turned off When the air conditioner is turned onCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting PROBLEMSOLUTION not work at allError is indicated Noise is generatedflow movement changes. It is normal the outdoor unitIncluded Models INSTALLATION PARTSGeneral information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit When installing 1 outdoor unit When installing more than 1 outdoor unitSpace Requirements for Outdoor Unit Top viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Power cableof the electrical contact during a wiring work Installing and connecting the assembly pipe of the indoor unit 10. Connect the grounding conductor to the grounding terminals11. Close the terminal board cover by tightening the screw carefully 2. Smooth the cut edgesPurging the indoor unit Cutting or extending the pipe4. Cut off the remaining foam insulation 6. Pass the pipe through the hole in the wall4. Put a flare nut slightly into the pipe and modify the flare Depth AOuter Diameter Outer Diameter DInstalling and connecting the drain hose of the indoor unit Drain hose installationInstalling and connecting the drain hose of the indoor unit Changing direction of the drain hose1. Detach the rubber cap with the plier 2. Detach the drain hose by pulling it and turning to the leftInstallAA ing and connecting the drain hose of the outdoor unit Purging the connected pipes2. Connect a drain hose to the drain plug 3. Ensure that condensation draining is adequategas service port as seen in the picture Adding RefrigerantIf you use a pipe longer than 5m If you use a pipe shorter than 5mImportant information regulation regarding the refrigerant used Cylinder with siphon1. Please fill in with indelible ink 1975PerfoAA rming the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesOutdoor unit installed on the wall by rack 6. Attach the pipe to the wall using clamps optionalFixinAA g the indoor unit in place Fixing the outdoor unit in place1. Press the Power button and check the following 4. Press the Power button to stop the operationFinalAA Check and Trial Operation Check the followingsThe compression dimension should be and compress another two points in the same location5. Apply heat to the contraction tube to contract it 6. After tube contraction work is completed, wrap it with theSub PCB installationoptional 1. Turn the power off and take off the front panel of the indoor unit2. Take off the Cover PCB 3. Attach the Sub PCB to the right side of the Panel-frameENGLISH QUESTIONS OR COMMENTS? COUNTRYCALL EEE Yönetmeliğine Uygundur This EEE is compliant with RoHSuser & installation manual Air Conditionerimagine the possibilities AQV07P Series AQV09P Series AQV12P Series AQV18P Series
Related manuals
Manual 41 pages 25.73 Kb Manual 41 pages 25.56 Kb Manual 41 pages 6.72 Kb Manual 45 pages 23.92 Kb Manual 41 pages 27.43 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 41 pages 20.41 Kb Manual 21 pages 39.04 Kb Manual 21 pages 44.89 Kb Manual 21 pages 49.66 Kb Manual 21 pages 36.79 Kb Manual 21 pages 55.58 Kb Manual 45 pages 44.27 Kb Manual 45 pages 56.11 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb