Choosing the installation location
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
Where there is no risk of flammable gas leakage
When installing the unit at a high place be sure to fix the unit legs
3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
• Avoid the following places to prevent malfunction of the unit
- Where there is machine oil | - Salty environment such as seaside areas |
- Where sulfide gas exists | - Other special atmosphere areas |
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner. If using a multi system, install as described in the installation manual supplied with the outdoor unit.
300mm or more
125mm or more
Wrap the refrigerant pipes and the drain hose | You can select the direction of | |
with the absorbent pad and vinyl tape. Refer to | ||
draining | ||
page 39 for further details. | ||
(left or right). | ||
| ||
| 'L' m as maximum pipe length | |
| and 3 m as minimum pipe length | |
| (It will reduce noise and vibration) | |
600mm | ' L ' meters maximum | |
total pipe length | ||
minimum |
| |
300mm |
| |
minimum | 300mm | |
| ||
| minimum | |
600mm |
| |
minimum |
|
125mm or more
'H ' meters maximum total pipe length
Model | L | H |
09/12 | 15 | 8 |
18/24 | 30 | 15 |
Make at least one round: It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
24