Samsung AQV24PSBNSER Remote controller display, Battery changing time, Inserting the batteries

Page 9
 Remote controller display

Turbo indicator Remote controller display

 

Operation mode

Turbo indicator

indicator

Low battery indicator

Quiet indicator

Transmit indicator

Smart Saver indicator

Air swing indicator

 

 

Fan speed indicator

On Timer indicator

Auto (Turbo)

Low

Off Timer indicator

Medium

indicator

High

 

Battery changing time

When the battery is exhausted, (indicator) will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for long time, remove the batteries from the remote controller and store it.

Inserting the batteries

ENGLISHQuiet indicator

1.Push the lever as arrow indicates on the rear side of the remote controller and pull up.

2.Insert two AAA batteries.

Check and match the“+”and“-” signs accordingly. Make sure you have inserted the batteries in correct position.

3.Close the cover by place it back to its original position.

You should hear click sound when the cover is locked properly.

• The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps

are in the same space.

• If other electrical products operate by the remote controller, call your nearest contact center.

Correct disposal of batteries in this product

(Applicable in countries with separate collection systems)

This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66.

If batteries are not properly disposed of, these substances can cause harm to human health or the environment.

To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system.

9

Image 9 Contents
Page Cool Summer Offer Features of your new air conditionerCost Efficient System Look for EverywhereUSING PARTS Safety precautionsImportant safety symbols and precautions FOR INSTALLATIONFOR POWER SUPPLY FOR USINGDo not pull the power cord, when unplugging the power plug Do not touch the power plug or the circuit breaker with wet handsDo not clean the inside of the air conditioner by yourself FOR CLEANINGDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsOperation ranges Checking before useModel RJ Maintaining your air conditionerChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerRemote controller display Smart Saver On TimerBattery changing time Remote controller displayStoring the remote controller Turbo indicatorAuto Basic functionCool HeatPress the button to turn on the air conditioner button to adjust the temperaturePress the button to set the operating mode Press theUsing the Turbo function Adjusting the air flow directionPress the Air swingbutton on the remote controller Press the Turbo button on the remote controller during Cool mode1. Press the button on the remote controller When the air conditioner is on and in cool/heat modemode Temperature and fan speed changes in modeSetting On timer Setting Off timer Setting the On/Off timer1. Press the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on Using the Smart Saver functionIf the air conditioner is off Combining On Timer and Off TimerUsing the Auto Clean function Using the Quiet functionPress the Auto Clean button When the air conditioner is turned off When the air conditioner is turned onCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaPeriodical checks Maintaining the air conditionerPROBLEM TroubleshootingSOLUTION not work at allNoise is generated Error is indicatedflow movement changes. It is normal the outdoor unitINSTALLATION PARTS General informationIncluded Models Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit When installing more than 1 outdoor unit When installing 1 outdoor unitSpace Requirements for Outdoor Unit Top viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Power cableof the electrical contact during a wiring work 10. Connect the grounding conductor to the grounding terminals Installing and connecting the assembly pipe of the indoor unit11. Close the terminal board cover by tightening the screw carefully 2. Smooth the cut edgesCutting or extending the pipe Purging the indoor unit4. Cut off the remaining foam insulation 6. Pass the pipe through the hole in the wallDepth A 4. Put a flare nut slightly into the pipe and modify the flareOuter Diameter Outer Diameter DDrain hose installation Installing and connecting the drain hose of the indoor unitChanging direction of the drain hose Installing and connecting the drain hose of the indoor unit1. Detach the rubber cap with the plier 2. Detach the drain hose by pulling it and turning to the leftPurging the connected pipes InstallAA ing and connecting the drain hose of the outdoor unit2. Connect a drain hose to the drain plug 3. Ensure that condensation draining is adequateAdding Refrigerant gas service port as seen in the pictureIf you use a pipe longer than 5m If you use a pipe shorter than 5mCylinder with siphon Important information regulation regarding the refrigerant used1. Please fill in with indelible ink 1975To check for gas leaks on the outdoor unit PerfoAA rming the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valves6. Attach the pipe to the wall using clamps optional Outdoor unit installed on the wall by rackFixinAA g the indoor unit in place Fixing the outdoor unit in place4. Press the Power button to stop the operation 1. Press the Power button and check the followingFinalAA Check and Trial Operation Check the followingsand compress another two points in the same location The compression dimension should be5. Apply heat to the contraction tube to contract it 6. After tube contraction work is completed, wrap it with the1. Turn the power off and take off the front panel of the indoor unit Sub PCB installationoptional2. Take off the Cover PCB 3. Attach the Sub PCB to the right side of the Panel-frameENGLISH COUNTRY QUESTIONS OR COMMENTS?CALL EEE Yönetmeliğine Uygundur This EEE is compliant with RoHSAir Conditioner user & installation manualimagine the possibilities AQV07P Series AQV09P Series AQV12P Series AQV18P Series
Related manuals
Manual 41 pages 25.73 Kb Manual 41 pages 25.56 Kb Manual 41 pages 6.72 Kb Manual 45 pages 23.92 Kb Manual 41 pages 27.43 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 41 pages 20.41 Kb Manual 21 pages 39.04 Kb Manual 21 pages 44.89 Kb Manual 21 pages 49.66 Kb Manual 21 pages 36.79 Kb Manual 21 pages 55.58 Kb Manual 45 pages 44.27 Kb Manual 45 pages 56.11 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb